Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2018 2
2019 31
2020 35
2021 55
2022 38
2023 37
2024 21

Text availability

Article attribute

Article type

Publication date

Search Results

193 results

Results by year

Filters applied: . Clear all
Page 1
Glycated albumin.
Zendjabil M. Zendjabil M. Clin Chim Acta. 2020 Mar;502:240-244. doi: 10.1016/j.cca.2019.11.007. Epub 2019 Nov 14. Clin Chim Acta. 2020. PMID: 31734145 Review.
GA can be measured accurately either on serum or plasma collected on tubes containing lithium heparin or EDTA as anticoagulant. The introduction of a new enzymatic assay has increased the diffusion of this test, in both research and clinical settings. ...
GA can be measured accurately either on serum or plasma collected on tubes containing lithium heparin or EDTA as anticoagulant …
Heparanase modulation by Wingless/INT (Wnt).
Melo CM, Nader HB, Justo GZ, Pinhal MAS. Melo CM, et al. Mol Biol Rep. 2021 Apr;48(4):3117-3125. doi: 10.1007/s11033-021-06348-3. Epub 2021 Apr 23. Mol Biol Rep. 2021. PMID: 33891270
The Wnt/beta-catenin pathway, judged by TCF-driven luciferase activity, seems to be involved to enhance heparanase profile during treatment with exogenous heparin. Lithium chloride treatment, an activator of the Wnt/beta-catenin pathway, confirmed such mechanism of …
The Wnt/beta-catenin pathway, judged by TCF-driven luciferase activity, seems to be involved to enhance heparanase profile during treatment …
Pseudohyperkalemia in chronic lymphocytic leukemia: Prevalence, impact, and management challenges.
Bnaya A, Ganzel C, Shavit L. Bnaya A, et al. Am J Med Sci. 2023 Sep;366(3):167-175. doi: 10.1016/j.amjms.2023.04.031. Epub 2023 Jun 5. Am J Med Sci. 2023. PMID: 37285937 Review.
Leukocyte fragility, extremely high leukocyte counts, mechanical stress, higher cell membrane permeability related to an interaction with lithium heparin in plasma blood samples, and metabolite depletion due to a high leukocyte burden have been reported to contribut …
Leukocyte fragility, extremely high leukocyte counts, mechanical stress, higher cell membrane permeability related to an interaction with …
Impact of pre-analytical sample handling factors on plasma biomarkers of Alzheimer's disease.
Kurz C, Stöckl L, Schrurs I, Suridjan I, Gürsel SÜ, Bittner T, Jethwa A, Perneczky R. Kurz C, et al. J Neurochem. 2023 Apr;165(1):95-105. doi: 10.1111/jnc.15757. Epub 2023 Jan 23. J Neurochem. 2023. PMID: 36625424 Free article.
For all plasma biomarkers except Abeta42 and Abeta40, analyte levels were largely comparable between EDTA, lithium heparin, and sodium citrate tubes. Abeta42 and Abeta40 were most sensitive to pre-analytical handling, and the effects could only be partially compensa …
For all plasma biomarkers except Abeta42 and Abeta40, analyte levels were largely comparable between EDTA, lithium heparin, an …
False lithium toxicity secondary to lithium heparin test tube: A case report and review.
Brizzee L, Stone A, Palmer MC. Brizzee L, et al. Ment Health Clin. 2020 May 7;10(3):90-94. doi: 10.9740/mhc.2020.05.090. eCollection 2020 May. Ment Health Clin. 2020. PMID: 32420006 Free PMC article.
This case demonstrates a false elevation of serum lithium concentrations that can occur when blood samples are collected using lithium heparin (green-top) tubes. ...As this case demonstrates, lithium heparin tubes have the potential to cause fal …
This case demonstrates a false elevation of serum lithium concentrations that can occur when blood samples are collected using lit
Deviating glucose results in an international dual-center study. A root cause investigation.
Cadamuro J, Bergsten P, Mörwald K, Forslund A, Dahlbom M, Bergquist J, Ciba I, Brunner SM, Jabbour J, Weghuber D. Cadamuro J, et al. Biochem Med (Zagreb). 2022 Feb 15;32(1):011001. doi: 10.11613/BM.2022.011001. Epub 2021 Dec 15. Biochem Med (Zagreb). 2022. PMID: 34955677 Free PMC article. Review.
While the Vacuette FC-Mix tube (Greiner Bio-One, Kremsmunster, Austria) was used in Uppsala, in Salzburg blood collections were performed with a lithium heparin tube (LH-Monovette, Sarstedt, Germany). To prove our hypothesis, we collected two blood samples in either …
While the Vacuette FC-Mix tube (Greiner Bio-One, Kremsmunster, Austria) was used in Uppsala, in Salzburg blood collections were performed wi …
Lithium heparin interference in the Abbott enzymatic creatinine assay: the significance of under-filled tubes.
Squires M, Wise H, Holmes H, Hadfield K. Squires M, et al. Ann Clin Biochem. 2021 Nov;58(6):653-656. doi: 10.1177/00045632211040673. Epub 2021 Aug 31. Ann Clin Biochem. 2021. PMID: 34463152
CONCLUSIONS: Lithium heparin directly interferes in the Abbott Architect enzymatic creatinine assay. Under-filling lithium heparin tubes can lead to clinically significant over-estimation of creatinine results by this assay. ...
CONCLUSIONS: Lithium heparin directly interferes in the Abbott Architect enzymatic creatinine assay. Under-filling lithium
Stability of Glucose Concentrations in Frozen Plasma.
Pleus S, Freckmann G, Baumstark A, Haug C. Pleus S, et al. J Diabetes Sci Technol. 2022 Sep;16(5):1096-1100. doi: 10.1177/1932296820963657. Epub 2020 Oct 9. J Diabetes Sci Technol. 2022. PMID: 33034207 Free PMC article.
METHODS: In this study, venous blood samples were collected in lithium-heparin gel tubes. Plasma was separated immediately after blood was drawn, and from each of the 21 plasma samples, 6 aliquots were prepared for measurement at 6 time points: immediately and after …
METHODS: In this study, venous blood samples were collected in lithium-heparin gel tubes. Plasma was separated immediately aft …
Self-sampling of capillary blood for SARS-CoV-2 serology.
Brown L, Byrne RL, Fraser A, Owen SI, Cubas-Atienzar AI, Williams CT, Kay GA, Cuevas LE, Fitchett JRA, Fletcher T, Garrod G, Kontogianni K, Krishna S, Menzies S, Planche T, Sainter C, Staines HM, Turtle L, Adams ER. Brown L, et al. Sci Rep. 2021 Apr 8;11(1):7754. doi: 10.1038/s41598-021-86008-5. Sci Rep. 2021. PMID: 33833246 Free PMC article.
Thirty eight out of thirty nine participants were able to self-collect an adequate sample of capillary blood ( 50 l). Using plasma from venous blood collected in lithium heparin as the reference standard, matched capillary blood samples, collected in lithium
Thirty eight out of thirty nine participants were able to self-collect an adequate sample of capillary blood ( 50 l). Using plasma from veno …
A Pilot Study on Cannabidiol (CBD) and Eccentric Exercise: Impact on Inflammation, Performance, and Pain.
Stone WJ, Tolusso DV, Pancheco G, Brgoch S, Nguyen VT. Stone WJ, et al. Int J Exerc Sci. 2023 Jan 1;16(2):109-117. eCollection 2023. Int J Exerc Sci. 2023. PMID: 37114193 Free PMC article.
Venipunctures were taken before exercise and repeated at 24, 48, and 72 hours post exercise. Blood samples were centrifuged for 15 minutes in gel and lithium heparin vacutainers. Plasma was separated from cells and stored at -80 until analysis. ...
Venipunctures were taken before exercise and repeated at 24, 48, and 72 hours post exercise. Blood samples were centrifuged for 15 minutes i …
193 results