Warning: The NCBI web site requires JavaScript to function. more...
High flow biphasic positive airway pressure by helmet--effects on pressurization, tidal volume, carbon dioxide accumulation and noise exposure.
Moerer O, Herrmann P, Hinz J, Severgnini P, Calderini E, Quintel M, Pelosi P.
Crit Care. 2009;13(3):R85. Epub 2009 Jun 5.PMID: 19500369 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluation of carbon dioxide rebreathing during pressure support ventilation with airway management system (BiPAP) devices.
Lofaso F, Brochard L, Touchard D, Hang T, Harf A, Isabey D.
Chest. 1995 Sep;108(3):772-8.PMID: 7656632 [PubMed - indexed for MEDLINE]Related articlesFree article
Pressure support ventilation and biphasic positive airway pressure improve oxygenation by redistribution of pulmonary blood flow.
Carvalho AR, Spieth PM, Pelosi P, Beda A, Lopes AJ, Neykova B, Heller AR, Koch T, Gama de Abreu M.
Anesth Analg. 2009 Sep;109(3):856-65.PMID: 19690258 [PubMed - indexed for MEDLINE]Related articles
Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
Delgado E, Hete B, Hoffman LA, Tasota FJ, Pinsky MR.
Respir Care. 2001 Jun;46(6):577-85.PMID: 11353546 [PubMed - indexed for MEDLINE]Related articles
Factors affecting oxygen delivery with bi-level positive airway pressure.
Schwartz AR, Kacmarek RM, Hess DR.
Respir Care. 2004 Mar;49(3):270-5.PMID: 14982647 [PubMed - indexed for MEDLINE]Related articlesFree article
Influence of two different interfaces for noninvasive ventilation compared to invasive ventilation on the mechanical properties and performance of a respiratory system: a lung model study.
Moerer O, Fischer S, Hartelt M, Kuvaki B, Quintel M, Neumann P.
Chest. 2006 Jun;129(6):1424-31.PMID: 16778258 [PubMed - indexed for MEDLINE]Related articlesFree article
CO2 rebreathing during BiPAP ventilatory assistance.
Ferguson GT, Gilmartin M.
Am J Respir Crit Care Med. 1995 Apr;151(4):1126-35.PMID: 7697242 [PubMed - indexed for MEDLINE]Related articles
Physiologic evaluation of different levels of assistance during noninvasive ventilation delivered through a helmet.
Costa R, Navalesi P, Antonelli M, Cavaliere F, Craba A, Proietti R, Conti G.
Chest. 2005 Oct;128(4):2984-90.PMID: 16236976 [PubMed - indexed for MEDLINE]Related articlesFree article
Noninvasive ventilation acutely modifies heart rate variability in chronic obstructive pulmonary disease patients.
Borghi-Silva A, Reis MS, Mendes RG, Pantoni CB, Simões RP, Martins LE, Catai AM.
Respir Med. 2008 Aug;102(8):1117-23. Epub 2008 Jun 26.PMID: 18585024 [PubMed - indexed for MEDLINE]Related articles
Metabolic and respiratory variables during pressure support versus synchronized intermittent mandatory ventilation.
El-Khatib M, Bou-Khalil P, Zeineldine S, Kanj N, Abi-Saad G, Jamaleddine G.
Respiration. 2009;77(2):154-9. Epub 2008 Jun 11.PMID: 18547941 [PubMed - indexed for MEDLINE]Related articles
Ventilation with biphasic positive airway pressure in experimental lung injury. Influence of transpulmonary pressure on gas exchange and haemodynamics.
Henzler D, Dembinski R, Bensberg R, Hochhausen N, Rossaint R, Kuhlen R.
Intensive Care Med. 2004 May;30(5):935-43. Epub 2004 Feb 24.PMID: 14985965 [PubMed - indexed for MEDLINE]Related articles
Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation.
Moerer O, Beck J, Brander L, Costa R, Quintel M, Slutsky AS, Brunet F, Sinderby C.
Intensive Care Med. 2008 Sep;34(9):1615-23. Epub 2008 May 30.PMID: 18512045 [PubMed - indexed for MEDLINE]Related articlesFree article
[Biphasic positive airway pressure (BIPAP)--a new form of augmented ventilation]
Baum M, Benzer H, Putensen C, Koller W, Putz G.
Anaesthesist. 1989 Sep;38(9):452-8. German. PMID: 2686487 [PubMed - indexed for MEDLINE]Related articles
Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure ventilation.
Schettino GP, Chatmongkolchart S, Hess DR, Kacmarek RM.
Crit Care Med. 2003 Aug;31(8):2178-82.PMID: 12973177 [PubMed - indexed for MEDLINE]Related articles
[Invasive ventilation. Classification, technique and clinical experiences with BiPAP/APRV (Biphasic Positive Airway Pressure/Airway Pressure Release Ventilation)]
Antonsen K, Jacobsen E, Pedersen JE, Porsborg PA, Bonde J.
Ugeskr Laeger. 1996 Jan 22;158(4):413-9. Review. Danish. PMID: 8638300 [PubMed - indexed for MEDLINE]Related articles
Does inspiratory behaviour affect the efficiency of non-invasive ventilation in COPD patients?
Vanpee D, El Khawand C, Rousseau L, Jamart J, Delaunois L.
Respir Med. 2002 Sep;96(9):709-15.PMID: 12243317 [PubMed - indexed for MEDLINE]Related articles
Noisy pressure support ventilation: a pilot study on a new assisted ventilation mode in experimental lung injury.
Gama de Abreu M, Spieth PM, Pelosi P, Carvalho AR, Walter C, Schreiber-Ferstl A, Aikele P, Neykova B, Hübler M, Koch T.
Crit Care Med. 2008 Mar;36(3):818-27.PMID: 18431269 [PubMed - indexed for MEDLINE]Related articles
Randomized prospective crossover study of biphasic intermittent positive airway pressure ventilation (BIPAP) versus pressure support ventilation (PSV) in surgical intensive care patients.
Elrazek EA.
Middle East J Anesthesiol. 2004 Oct;17(6):1009-21.PMID: 15651509 [PubMed - indexed for MEDLINE]Related articles
Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation.
Thille AW, Cabello B, Galia F, Lyazidi A, Brochard L.
Intensive Care Med. 2008 Aug;34(8):1477-86. Epub 2008 Apr 24.PMID: 18437356 [PubMed - indexed for MEDLINE]Related articles
Carbon dioxide rebreathing during non-invasive ventilation delivered by helmet: a bench study.
Mojoli F, Iotti GA, Gerletti M, Lucarini C, Braschi A.
Intensive Care Med. 2008 Aug;34(8):1454-60. Epub 2008 Apr 18.PMID: 18421436 [PubMed - indexed for MEDLINE]Related articles
Filter your results:
Your browsing activity is empty.
Activity recording is turned off.
Turn recording back on