Comparison of the numerical and clinical accuracy of four continuous glucose monitors.
Kovatchev B, Anderson S, Heinemann L, Clarke W.
Diabetes Care. 2008 Jun;31(6):1160-4. Epub 2008 Mar 13.PMID: 18339974 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.
Clarke WL, Anderson S, Farhy L, Breton M, Gonder-Frederick L, Cox D, Kovatchev B.
Diabetes Care. 2005 Oct;28(10):2412-7.PMID: 16186272 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.
Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL.
Diabetes Care. 2004 Aug;27(8):1922-8.PMID: 15277418 [PubMed - indexed for MEDLINE]Related articlesFree article
Comparison of the numerical and clinical accuracy of four continuous glucose monitors: response to Kovatchev et al.
Brauker J, Matsubara B.
Diabetes Care. 2008 Oct;31(10):e80; author reply e81. No abstract available. PMID: 18820226 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans.
Rossetti P, Porcellati F, Fanelli CG, Bolli GB.
Diabetes Technol Ther. 2006 Jun;8(3):326-37.PMID: 16800754 [PubMed - indexed for MEDLINE]Related articles
The accuracy of the CGMS in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study.
Diabetes Research in Children Network (DIRECNET) Study Group.
Diabetes Technol Ther. 2003;5(5):781-9.PMID: 14633343 [PubMed - indexed for MEDLINE]Related articlesFree article
Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.
Weinstein RL, Schwartz SL, Brazg RL, Bugler JR, Peyser TA, McGarraugh GV.
Diabetes Care. 2007 May;30(5):1125-30. Epub 2007 Mar 2.PMID: 17337488 [PubMed - indexed for MEDLINE]Related articlesFree article
The use of two continuous glucose sensors during and after surgery.
Vriesendorp TM, DeVries JH, Holleman F, Dzoljic M, Hoekstra JB.
Diabetes Technol Ther. 2005 Apr;7(2):315-22.PMID: 15857234 [PubMed - indexed for MEDLINE]Related articles
Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA).
Clarke WL, Anderson S, Kovatchev B.
Curr Diabetes Rev. 2008 Aug;4(3):193-9. Review.PMID: 18690900 [PubMed - indexed for MEDLINE]Related articles
Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?
Mazze RS, Strock E, Borgman S, Wesley D, Stout P, Racchini J.
Diabetes Technol Ther. 2009 Jan;11(1):11-8.PMID: 19132850 [PubMed - indexed for MEDLINE]Related articles
Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network.
Diabetes Research in Children Network (DirecNet) Study Group.
Diabetes Care. 2004 Mar;27(3):722-6.PMID: 14988292 [PubMed - indexed for MEDLINE]Related articlesFree article
Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system.
Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, Gross T, Mastrototaro J.
Diabetes Technol Ther. 2004 Apr;6(2):105-13.PMID: 15117576 [PubMed - indexed for MEDLINE]Related articles
A critical appraisal of the continuous glucose-error grid analysis.
Wentholt IM, Hoekstra JB, Devries JH.
Diabetes Care. 2006 Aug;29(8):1805-11.PMID: 16873784 [PubMed - indexed for MEDLINE]Related articlesFree article
Clinical assessment and mathematical modeling of the accuracy of continuous glucose sensors (CGS).
Kovatchev BP, King C, Breton M, Anderson S, Clarke W.
Conf Proc IEEE Eng Med Biol Soc. 2006;1:71-4.PMID: 17945569 [PubMed - indexed for MEDLINE]Related articles
Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes.
Garg SK, Schwartz S, Edelman SV.
Diabetes Care. 2004 Mar;27(3):734-8.PMID: 14988294 [PubMed - indexed for MEDLINE]Related articlesFree article
Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects.
Sachedina N, Pickup JC.
Diabet Med. 2003 Dec;20(12):1012-5.PMID: 14632702 [PubMed - indexed for MEDLINE]Related articles
Continuous glucose monitoring and the reality of metabolic control in preschool children with type 1 diabetes.
Jeha GS, Karaviti LP, Anderson B, Smith EO, Donaldson S, McGirk TS, Haymond MW.
Diabetes Care. 2004 Dec;27(12):2881-6.PMID: 15562201 [PubMed - indexed for MEDLINE]Related articlesFree article
Efficacy of continuous glucose monitoring system to detect unrecognized hypoglycemia in children and adolescents with type 1 diabetes.
Maia FF, Araújo LR.
Arq Bras Endocrinol Metabol. 2005 Aug;49(4):569-74. Epub 2005 Oct 19.PMID: 16358087 [PubMed - indexed for MEDLINE]Related articlesFree article
The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.
Wilson DM, Beck RW, Tamborlane WV, Dontchev MJ, Kollman C, Chase P, Fox LA, Ruedy KJ, Tsalikian E, Weinzimer SA; DirecNet Study Group.
Diabetes Care. 2007 Jan;30(1):59-64.PMID: 17192334 [PubMed - indexed for MEDLINE]Related articlesFree article
The accuracy of the Guardian RT continuous glucose monitor in children with type 1 diabetes.
Diabetes Technol Ther. 2008 Aug;10(4):266-72.PMID: 18828242 [PubMed - indexed for MEDLINE]Related articlesFree article