Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

    Results: 1 to 20 of 931

    1.

    The influence of age, duration of diabetes, cataract, and pupil size on image quality in digital photographic retinal screening.

    Scanlon PH, Foy C, Malhotra R, Aldington SJ.

    Diabetes Care. 2005 Oct;28(10):2448-53.PMID: 16186278 [PubMed - indexed for MEDLINE]Related articlesFree article

    3.

    Comparison of nonmydriatic digital retinal imaging versus dilated ophthalmic examination for nondiabetic eye disease in persons with diabetes.

    Chow SP, Aiello LM, Cavallerano JD, Katalinic P, Hock K, Tolson A, Kirby R, Bursell SE, Aiello LP.

    Ophthalmology. 2006 May;113(5):833-40.PMID: 16650680 [PubMed - indexed for MEDLINE]Related articles

    4.

    Effect of mydriasis and different field strategies on digital image screening of diabetic eye disease.

    Murgatroyd H, Ellingford A, Cox A, Binnie M, Ellis JD, MacEwen CJ, Leese GP.

    Br J Ophthalmol. 2004 Jul;88(7):920-4.PMID: 15205238 [PubMed - indexed for MEDLINE]Related articlesFree article

    5.

    Can we predict which patients are at risk of having an ungradeable digital image for screening for diabetic retinopathy?

    Murgatroyd H, Cox A, Ellingford A, Ellis JD, Macewen CJ, Leese GP.

    Eye (Lond). 2008 Mar;22(3):344-8. Epub 2006 Oct 6.PMID: 17024219 [PubMed - indexed for MEDLINE]Related articles

    6.

    Screening for diabetic retinopathy using a non-mydriatic retinal camera in rural Victoria.

    Harper CA, Livingston PM, Wood C, Jin C, Lee SJ, Keeffe JE, McCarty CA, Taylor HR.

    Aust N Z J Ophthalmol. 1998 May;26(2):117-21.PMID: 9630291 [PubMed - indexed for MEDLINE]Related articles

    7.

    Stereo nonmydriatic digital-video color retinal imaging compared with Early Treatment Diabetic Retinopathy Study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy.

    Bursell SE, Cavallerano JD, Cavallerano AA, Clermont AC, Birkmire-Peters D, Aiello LP, Aiello LM; Joslin Vision Network Research Team.

    Ophthalmology. 2001 Mar;108(3):572-85.PMID: 11237913 [PubMed - indexed for MEDLINE]Related articles

    8.

    Screening for diabetic retinopathy: the utility of nonmydriatic retinal photography in Egyptian adults.

    Penman AD, Saaddine JB, Hegazy M, Sous ES, Ali MA, Brechner RJ, Herman WH, Engelgau MM, Klein R.

    Diabet Med. 1998 Sep;15(9):783-7.PMID: 9737809 [PubMed - indexed for MEDLINE]Related articles

    9.

    Effectiveness and safety of screening for diabetic retinopathy with two nonmydriatic digital images compared with the seven standard stereoscopic photographic fields.

    Boucher MC, Gresset JA, Angioi K, Olivier S.

    Can J Ophthalmol. 2003 Dec;38(7):557-68.PMID: 14740797 [PubMed - indexed for MEDLINE]Related articles

    10.

    Screening coverage for diabetic retinopathy using a three-field digital non-mydriatic fundus camera.

    Soto-Pedre E, Hernaez-Ortega MC.

    Prim Care Diabetes. 2008 Sep;2(3):141-6. Epub 2008 Jun 4.PMID: 18779038 [PubMed - indexed for MEDLINE]Related articles

    11.

    Comparison of two, three and four 45 degrees image fields obtained with the Topcon CRW6 nonmydriatic camera for screening for diabetic retinopathy.

    Perrier M, Boucher MC, Angioi K, Gresset JA, Olivier S.

    Can J Ophthalmol. 2003 Dec;38(7):569-74.PMID: 14740798 [PubMed - indexed for MEDLINE]Related articles

    12.

    Screening for diabetic retinopathy: 1 and 3 nonmydriatic 45-degree digital fundus photographs vs 7 standard early treatment diabetic retinopathy study fields.

    Vujosevic S, Benetti E, Massignan F, Pilotto E, Varano M, Cavarzeran F, Avogaro A, Midena E.

    Am J Ophthalmol. 2009 Jul;148(1):111-8. Epub 2009 May 5.PMID: 19406376 [PubMed - indexed for MEDLINE]Related articles

    13.

    The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy.

    Scanlon PH, Malhotra R, Thomas G, Foy C, Kirkpatrick JN, Lewis-Barned N, Harney B, Aldington SJ.

    Diabet Med. 2003 Jun;20(6):467-74.PMID: 12786681 [PubMed - indexed for MEDLINE]Related articles

    14.

    Web-based grading of compressed stereoscopic digital photography versus standard slide film photography for the diagnosis of diabetic retinopathy.

    Rudnisky CJ, Tennant MT, Weis E, Ting A, Hinz BJ, Greve MD.

    Ophthalmology. 2007 Sep;114(9):1748-54. Epub 2007 Mar 21.PMID: 17368543 [PubMed - indexed for MEDLINE]Related articles

    15.

    Two-field photography can identify patients with vision-threatening diabetic retinopathy: a screening approach in the primary care setting.

    Stellingwerf C, Hardus PL, Hooymans JM.

    Diabetes Care. 2001 Dec;24(12):2086-90.PMID: 11723088 [PubMed - indexed for MEDLINE]Related articlesFree article

    16.

    Screening for sight-threatening diabetic retinopathy: comparison of fundus photography with automated color contrast threshold test.

    Ong GL, Ripley LG, Newsom RS, Cooper M, Casswell AG.

    Am J Ophthalmol. 2004 Mar;137(3):445-52.PMID: 15013866 [PubMed - indexed for MEDLINE]Related articles

    17.

    Screening for diabetic retinopathy by one-field, non-mydriatic, 45 degrees digital photography is inadequate.

    Kuo HK, Hsieh HH, Liu RT.

    Ophthalmologica. 2005 Sep-Oct;219(5):292-6.PMID: 16123556 [PubMed - indexed for MEDLINE]Related articles

    18.

    Screening for diabetic retinopathy using a digital non-mydriatic camera compared with standard 35-mm stereo colour transparencies.

    Hansen AB, Sander B, Larsen M, Kleener J, Borch-Johnsen K, Klein R, Lund-Andersen H.

    Acta Ophthalmol Scand. 2004 Dec;82(6):656-65.PMID: 15606460 [PubMed - indexed for MEDLINE]Related articles

    19.

    Diabetic retinopathy screening using digital non-mydriatic fundus photography and automated image analysis.

    Hansen AB, Hartvig NV, Jensen MS, Borch-Johnsen K, Lund-Andersen H, Larsen M.

    Acta Ophthalmol Scand. 2004 Dec;82(6):666-72.PMID: 15606461 [PubMed - indexed for MEDLINE]Related articles

    20.

    Identification of diabetic retinopathy by stereoscopic digital imaging via teleophthalmology: a comparison to slide film.

    Tennant MT, Greve MD, Rudnisky CJ, Hillson TR, Hinz BJ.

    Can J Ophthalmol. 2001 Jun;36(4):187-96.PMID: 11428527 [PubMed - indexed for MEDLINE]Related articles