    1.

    Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution.

    Yan YS, Poon CC, Zhang YT.

    J Neuroeng Rehabil. 2005 Mar 1;2(1):3.PMID: 15737241 [PubMed - as supplied by publisher]Related articlesFree article

    2.

    The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.

    Gehring H, Hornberger C, Matz H, Konecny E, Schmucker P.

    Respir Care. 2002 Jan;47(1):48-60.PMID: 11749687 [PubMed - indexed for MEDLINE]Related articles

    3.

    The effects of motion on the performance of pulse oximeters in volunteers (revised publication).

    Barker SJ, Shah NK.

    Anesthesiology. 1997 Jan;86(1):101-8.PMID: 9009945 [PubMed - indexed for MEDLINE]Related articlesFree article

    4.

    Smoothed pseudo Wigner-Ville distribution as an alternative to Fourier transform in rats.

    Pereira de Souza Neto E, Custaud MA, Frutoso J, Somody L, Gharib C, Fortrat JO.

    Auton Neurosci. 2001 Mar 23;87(2-3):258-67.PMID: 11476287 [PubMed - indexed for MEDLINE]Related articles

    5.

    Effects of motion on the performance of pulse oximeters in volunteers.

    Barker SJ, Shah NK.

    Anesthesiology. 1996 Oct;85(4):774-81.PMID: 8873547 [PubMed - indexed for MEDLINE]Related articlesFree article

    6.

    Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.

    Kyriacou PA, Powell S, Langford RM, Jones DP.

    Physiol Meas. 2002 Aug;23(3):533-45.PMID: 12214761 [PubMed - indexed for MEDLINE]Related articles

    7.

    A comparative evaluation of adaptive noise cancellation algorithms for minimizing motion artifacts in a forehead-mounted wearable pulse oximeter.

    Comtois G, Mendelson Y, Ramuka P.

    Conf Proc IEEE Eng Med Biol Soc. 2007;2007:1528-31.PMID: 18002258 [PubMed - indexed for MEDLINE]Related articles

    8.

    Clinical use of new-generation pulse oximeters in the neonatal intensive care unit.

    Workie FA, Rais-Bahrami K, Short BL.

    Am J Perinatol. 2005 Oct;22(7):357-60.PMID: 16215921 [PubMed - indexed for MEDLINE]Related articles

    10.

    Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account.

    Meyts I, Reempts PV, Boeck KD.

    Eur J Pediatr. 2002 Dec;161(12):653-5. Epub 2002 Nov 6.PMID: 12447664 [PubMed - indexed for MEDLINE]Related articles

    11.

    Identification of movement artefact by the Nellcor N-200 and N-3000 pulse oximeters.

    Plummer JL, Ilsley AH, Fronsko RR, Owen H.

    J Clin Monit. 1997 Mar;13(2):109-13.PMID: 9112206 [PubMed - indexed for MEDLINE]Related articles

    12.

    [Study on resistance to motion artifact in pulse oximetry measurement using segment filter method]

    Li QB, Nie X, Zhang GJ, Wu JG.

    Guang Pu Xue Yu Guang Pu Fen Xi. 2009 Nov;29(11):2994-7. Chinese. PMID: 20101971 [PubMed - in process]Related articles

    13.

    Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography.

    Han H, Kim MJ, Kim J.

    Conf Proc IEEE Eng Med Biol Soc. 2007;2007:1538-41.PMID: 18002262 [PubMed - indexed for MEDLINE]Related articles

    14.

    Masimo signal extraction pulse oximetry.

    Goldman JM, Petterson MT, Kopotic RJ, Barker SJ.

    J Clin Monit Comput. 2000;16(7):475-83.PMID: 12580205 [PubMed - indexed for MEDLINE]Related articles

    15.

    Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    Kästle SW, Konecny E.

    J Clin Monit Comput. 2000;16(7):509-22.PMID: 12580210 [PubMed - indexed for MEDLINE]Related articles

    16.

    A prototype device for standardized calibration of pulse oximeters II.

    Hornberger Ch, Knoop P, Matz H, Dörries F, Konecny E, Gehring H, Otten J, Bonk R, Frankenberger H, Wouters P, Gil-Rodriguez J, Ponz L, Avgerinos J, Karoutis A, Ikiades A, Weininger S.

    J Clin Monit Comput. 2002 Apr-May;17(3-4):203-9.PMID: 12455737 [PubMed - indexed for MEDLINE]Related articles

    17.

    Motion artefact reduction of the photoplethysmographic signal in pulse transit time measurement.

    Foo JY, Wilson SJ, Williams GR, Harris M, Cooper DM.

    Australas Phys Eng Sci Med. 2004 Dec;27(4):165-73.PMID: 15712583 [PubMed - indexed for MEDLINE]Related articles

    18.

    Effects of motion, ambient light, and hypoperfusion on pulse oximeter function.

    Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ.

    J Clin Anesth. 1997 May;9(3):179-83.PMID: 9172022 [PubMed - indexed for MEDLINE]Related articles

    19.

    Next-generation pulse oximetry. Focusing on Masimo's signal extraction technology.

    [No authors listed]

    Health Devices. 2000 Oct;29(10):349-70.PMID: 11094776 [PubMed - indexed for MEDLINE]Related articles