Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.
Kovatchev BP, Gonder-Frederick LA, Cox DJ, Clarke WL.
Diabetes Care. 2004 Aug;27(8):1922-8.PMID: 15277418 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.
Clarke WL, Anderson S, Farhy L, Breton M, Gonder-Frederick L, Cox D, Kovatchev B.
Diabetes Care. 2005 Oct;28(10):2412-7.PMID: 16186272 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA).
Clarke WL, Anderson S, Kovatchev B.
Curr Diabetes Rev. 2008 Aug;4(3):193-9. Review.PMID: 18690900 [PubMed - indexed for MEDLINE]Related articles
A critical appraisal of the continuous glucose-error grid analysis.
Wentholt IM, Hoekstra JB, Devries JH.
Diabetes Care. 2006 Aug;29(8):1805-11.PMID: 16873784 [PubMed - indexed for MEDLINE]Related articlesFree article
Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application.
Kovatchev BP, Clarke WL, Breton M, Brayman K, McCall A.
Diabetes Technol Ther. 2005 Dec;7(6):849-62.PMID: 16386091 [PubMed - indexed for MEDLINE]Related articles
Comparison of the numerical and clinical accuracy of four continuous glucose monitors.
Kovatchev B, Anderson S, Heinemann L, Clarke W.
Diabetes Care. 2008 Jun;31(6):1160-4. Epub 2008 Mar 13.PMID: 18339974 [PubMed - indexed for MEDLINE]Related articlesFree article
Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.
Weinstein RL, Schwartz SL, Brazg RL, Bugler JR, Peyser TA, McGarraugh GV.
Diabetes Care. 2007 May;30(5):1125-30. Epub 2007 Mar 2.PMID: 17337488 [PubMed - indexed for MEDLINE]Related articlesFree article
Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors.
Breton M, Kovatchev B.
J Diabetes Sci Technol. 2008 Sep 1;2(5):853-862.PMID: 19750186 [PubMed]Related articlesFree article
Clinical assessment and mathematical modeling of the accuracy of continuous glucose sensors (CGS).
Kovatchev BP, King C, Breton M, Anderson S, Clarke W.
Conf Proc IEEE Eng Med Biol Soc. 2006;1:71-4.PMID: 17945569 [PubMed - indexed for MEDLINE]Related articles
Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.
Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L.
Diabetes Care. 2006 Jan;29(1):44-50.PMID: 16373894 [PubMed - indexed for MEDLINE]Related articlesFree article
Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.
McGarraugh G, Bergenstal R.
Diabetes Technol Ther. 2009 Mar;11(3):145-50.PMID: 19216686 [PubMed - indexed for MEDLINE]Related articles
The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.
Wilson DM, Beck RW, Tamborlane WV, Dontchev MJ, Kollman C, Chase P, Fox LA, Ruedy KJ, Tsalikian E, Weinzimer SA; DirecNet Study Group.
Diabetes Care. 2007 Jan;30(1):59-64.PMID: 17192334 [PubMed - indexed for MEDLINE]Related articlesFree article
Glucose Prediction Algorithms from Continuous Monitoring Data: Assessment of Accuracy via Continuous Glucose Error-Grid Analysis.
Zanderigo F, Sparacino G, Kovatchev B, Cobelli C.
J Diabetes Sci Technol. 2007 Sep 1;1(5):645-651.PMID: 19718282 [PubMed]Related articlesFree article
Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors.
Kollman C, Wilson DM, Wysocki T, Tamborlane WV, Beck RW; Diabetes Research in Children Network Study Group.
Diabetes Technol Ther. 2005 Oct;7(5):665-72; discussion 673-4.PMID: 16241865 [PubMed - indexed for MEDLINE]Related articlesFree article
The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes.
Mastrototaro J, Shin J, Marcus A, Sulur G; STAR 1 Clinical Trial Investigators.
Diabetes Technol Ther. 2008 Oct;10(5):385-90.PMID: 18715215 [PubMed - indexed for MEDLINE]Related articles
Graphical and numerical evaluation of continuous glucose sensing time lag.
Kovatchev BP, Shields D, Breton M.
Diabetes Technol Ther. 2009 Mar;11(3):139-43.PMID: 19216687 [PubMed - indexed for MEDLINE]Related articles
A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic.
Thomas LE, Kane MP, Bakst G, Busch RS, Hamilton RA, Abelseth JM.
Diabetes Technol Ther. 2008 Apr;10(2):102-10.PMID: 18260773 [PubMed - indexed for MEDLINE]Related articles
[Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes]
Maia FF, Araújo LR.
J Pediatr (Rio J). 2005 Jul-Aug;81(4):293-7. Portuguese. PMID: 16106313 [PubMed - indexed for MEDLINE]Related articlesFree article
Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?
Mazze RS, Strock E, Borgman S, Wesley D, Stout P, Racchini J.
Diabetes Technol Ther. 2009 Jan;11(1):11-8.PMID: 19132850 [PubMed - indexed for MEDLINE]Related articles
Experience with the continuous glucose monitoring system in a medical intensive care unit.
Goldberg PA, Siegel MD, Russell RR, Sherwin RS, Halickman JI, Cooper DA, Dziura JD, Inzucchi SE.
Diabetes Technol Ther. 2004 Jun;6(3):339-47.PMID: 15198837 [PubMed - indexed for MEDLINE]Related articles