Warning: The NCBI web site requires JavaScript to function. more...
Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear.
Looney RJ, Boyd A, Totterman S, Seo GS, Tamez-Pena J, Campbell D, Novotny L, Olcott C, Martell J, Hayes FA, O'Keefe RJ, Schwarz EM.
Arthritis Res. 2002;4(1):59-63. Epub 2001 Oct 3.
Related citations
Progression of acetabular periprosthetic osteolytic lesions measured with computed tomography.
Howie DW, Neale SD, Stamenkov R, McGee MA, Taylor DJ, Findlay DM.
J Bone Joint Surg Am. 2007 Aug;89(8):1818-25.
Use of volumetric computerized tomography as a primary outcome measure to evaluate drug efficacy in the prevention of peri-prosthetic osteolysis: a 1-year clinical pilot of etanercept vs. placebo.
Schwarz EM, Campbell D, Totterman S, Boyd A, O'Keefe RJ, Looney RJ.
J Orthop Res. 2003 Nov;21(6):1049-55.
Pelvic osteolysis relationship to radiographs and polyethylene wear.
Shon WY, Gupta S, Biswal S, Han SH, Hong SJ, Moon JG.
J Arthroplasty. 2009 Aug;24(5):743-50. Epub 2008 Jun 13.
Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty.
Puri L, Wixson RL, Stern SH, Kohli J, Hendrix RW, Stulberg SD.
J Bone Joint Surg Am. 2002 Apr;84-A(4):609-14.
A three-dimensional method for evaluating changes in acetabular osteolytic lesions in response to treatment.
Egawa H, Ho H, Huynh C, Hopper RH Jr, Engh CA Jr, Engh CA.
Clin Orthop Relat Res. 2010 Feb;468(2):480-90. Epub 2009 Aug 22.
Computed tomography to assess pelvic lysis after total hip replacement.
Claus AM, Totterman SM, Sychterz CJ, Tamez-Peña JG, Looney RJ, Engh CA Sr.
Clin Orthop Relat Res. 2004 May;(422):167-74.
Characteristics of pelvic osteolysis on computed tomography after total hip arthroplasty.
Kitamura N, Leung SB, Engh CA Sr.
Clin Orthop Relat Res. 2005 Dec;441:291-7.
Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique.
Vandenbussche E, Saffarini M, Hansen U, Taillieu F, Mutschler C, Augereau B, Gregory TM.
Acta Orthop. 2010 Oct;81(5):563-9.
Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty: minimal 5-year follow-up study.
Han CD, Choe WS, Yoo JH.
J Arthroplasty. 1999 Sep;14(6):714-23.
Magnetic resonance imaging in the evaluation of periprosthetic acetabular osteolysis: a cadaveric study.
Weiland DE, Walde TA, Leung SB, Sychterz CJ, Ho S, Engh CA, Potter HG.
J Orthop Res. 2005 Jul;23(4):713-9. Epub 2005 Apr 12.
Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty.
Zhang H, Pei FX, Yang J, Shen B, Shi R.
Chin J Traumatol. 2005 Oct;8(5):263-8.
The quality of osteolysis grafting with cementless acetabular component retention.
Engh CA Jr, Egawa H, Beykirch SE, Hopper RH Jr, Engh CA.
Clin Orthop Relat Res. 2007 Dec;465:150-4.
Focal osteolysis in total hip replacement: CT findings.
Park JS, Ryu KN, Hong HP, Park YK, Chun YS, Yoo MC.
Skeletal Radiol. 2004 Nov;33(11):632-40. Epub 2004 Jul 31.
Relationship between the pelvic osteolytic volume on computed tomography and clinical outcome in patients with cementless acetabular components.
Yun HH, Shon WY, Hong SJ, Yoon JR, Yang JH.
Int Orthop. 2011 Oct;35(10):1453-9. doi: 10.1007/s00264-010-1132-3. Epub 2010 Oct 7.
The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis.
Kitamura N, Pappedemos PC, Duffy PR 3rd, Stepniewski AS, Hopper RH Jr, Engh CA Jr, Engh CA.
Clin Orthop Relat Res. 2006 Dec;453:239-45.
Management of patients with acetabular socket wear and pelvic osteolysis.
Claus AM, Walde TA, Leung SB, Wolf RL, Engh CA Sr.
J Arthroplasty. 2003 Apr;18(3 Suppl 1):112-7.
Influence of demographic, surgical and implant variables on wear rate and osteolysis in ABG I hip arthroplasty.
Gallo J, Havranek V, Cechova I, Zapletalova J.
Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2006 Jul;150(1):135-41.
Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: a study of 4 patients.
van Ooij A, Kurtz SM, Stessels F, Noten H, van Rhijn L.
Spine (Phila Pa 1976). 2007 Jan 15;32(2):223-9. Erratum in: Spine. 2007 Apr 20;32(9):1052.
Particle-induced osteolysis in three-dimensional micro-computed tomography.
Wedemeyer C, Xu J, Neuerburg C, Landgraeber S, Malyar NM, von Knoch F, Gosheger G, von Knoch M, Löer F, Saxler G.
Calcif Tissue Int. 2007 Nov;81(5):394-402. Epub 2007 Oct 21.
Filter your results:
Your browsing activity is empty.
Activity recording is turned off.
Turn recording back on