Warning: The NCBI web site requires JavaScript to function. more...
Computer algorithms for the automated measurement of retinal arteriolar diameters.
Chapman N, Witt N, Gao X, Bharath AA, Stanton AV, Thom SA, Hughes AD.
Br J Ophthalmol. 2001 Jan;85(1):74-9.PMID: 11133716 [PubMed - indexed for MEDLINE]Related articlesFree article
Asymmetry of retinal arteriolar branch widths at junctions affects ability of formulae to predict trunk arteriolar widths.
Patton N, Aslam T, Macgillivray T, Dhillon B, Constable I.
Invest Ophthalmol Vis Sci. 2006 Apr;47(4):1329-33.PMID: 16565364 [PubMed - indexed for MEDLINE]Related articlesFree article
Retinal vessel measurement: comparison between observer and computer driven methods.
Newsom RS, Sullivan PM, Rassam SM, Jagoe R, Kohner EM.
Graefes Arch Clin Exp Ophthalmol. 1992;230(3):221-5.PMID: 1597285 [PubMed - indexed for MEDLINE]Related articles
Computer-assisted measurement of retinal vessel diameters in the Beaver Dam Eye Study: methodology, correlation between eyes, and effect of refractive errors.
Wong TY, Knudtson MD, Klein R, Klein BE, Meuer SM, Hubbard LD.
Ophthalmology. 2004 Jun;111(6):1183-90.PMID: 15177969 [PubMed - indexed for MEDLINE]Related articles
Direct measurement of retinal vessel diameter: comparison with microdensitometric methods based on fundus photographs.
Suzuki Y.
Surv Ophthalmol. 1995 May;39 Suppl 1:S57-65.PMID: 7660313 [PubMed - indexed for MEDLINE]Related articles
Measuring arteriolar-to-venous ratio in retinal photography of patients with hypertension: development and application of a new semi-automated method.
Pakter HM, Ferlin E, Fuchs SC, Maestri MK, Moraes RS, Nunes G, Moreira LB, Gus M, Fuchs FD.
Am J Hypertens. 2005 Mar;18(3):417-21.PMID: 15797663 [PubMed - indexed for MEDLINE]Related articles
Automated detection and quantification of microaneurysms in fluorescein angiograms.
Spencer T, Phillips RP, Sharp PF, Forrester JV.
Graefes Arch Clin Exp Ophthalmol. 1992;230(1):36-41.PMID: 1547965 [PubMed - indexed for MEDLINE]Related articles
[Automated measurement of retinal vascular diameter]
Vilser W, Klein S, Wulff P, Siegel C, Fuchs G.
Fortschr Ophthalmol. 1991;88(5):482-6. German. PMID: 1757037 [PubMed - indexed for MEDLINE]Related articles
Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle.
Knudtson MD, Klein BE, Klein R, Wong TY, Hubbard LD, Lee KE, Meuer SM, Bulla CP.
Br J Ophthalmol. 2004 Jan;88(1):57-61.PMID: 14693774 [PubMed - indexed for MEDLINE]Related articlesFree article
A comparison of manual and automated methods of measuring conjunctival vessel widths from photographic and digital images.
Owen CG, Ellis TJ, Woodward EG.
Ophthalmic Physiol Opt. 2004 Mar;24(2):74-81.PMID: 15005671 [PubMed - indexed for MEDLINE]Related articles
Retinal vessel diameters and their associations with age and blood pressure.
Wong TY, Klein R, Klein BE, Meuer SM, Hubbard LD.
Invest Ophthalmol Vis Sci. 2003 Nov;44(11):4644-50.PMID: 14578380 [PubMed - indexed for MEDLINE]Related articlesFree article
[Adaptive algorithm for automatic measurement of retinal vascular diameter]
Münch K, Vilser W, Senff I.
Biomed Tech (Berl). 1995 Nov;40(11):322-5. German. PMID: 8580285 [PubMed - indexed for MEDLINE]Related articles
Measurement of retinal vessel widths from fundus images based on 2-D modeling.
Lowell J, Hunter A, Steel D, Basu A, Ryder R, Kennedy RL.
IEEE Trans Med Imaging. 2004 Oct;23(10):1196-204.PMID: 15493688 [PubMed - indexed for MEDLINE]Related articles
Segmentation of blood vessels from red-free and fluorescein retinal images.
Martinez-Perez ME, Hughes AD, Thom SA, Bharath AA, Parker KH.
Med Image Anal. 2007 Feb;11(1):47-61. Epub 2007 Jan 3.PMID: 17204445 [PubMed - indexed for MEDLINE]Related articles
Impact of simulated light scatter on the quantitative, noninvasive assessment of retinal arteriolar hemodynamics.
Azizi B, Buehler H, Venkataraman ST, Hudson C.
J Biomed Opt. 2007 May-Jun;12(3):034021.PMID: 17614729 [PubMed - indexed for MEDLINE]Related articles
Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: assessment of inter- and intraobserver variation.
Diehm N, Baumgartner I, Silvestro A, Herrmann P, Triller J, Schmidli J, Do DD, Dinkel HP.
Vasa. 2005 Nov;34(4):255-61.PMID: 16363281 [PubMed - indexed for MEDLINE]Related articles
Automatic grading of retinal vessel caliber.
Li H, Hsu W, Lee ML, Wong TY.
IEEE Trans Biomed Eng. 2005 Jul;52(7):1352-5.PMID: 16042001 [PubMed - indexed for MEDLINE]Related articles
An improved procedure to quantify tumour vascularity using true colour image analysis. Comparison with the manual hot-spot procedure in a human melanoma xenograft model.
van der Laak JA, Westphal JR, Schalkwijk LJ, Pahlplatz MM, Ruiter DJ, de Waal RM, de Wilde PC.
J Pathol. 1998 Feb;184(2):136-43.PMID: 9602703 [PubMed - indexed for MEDLINE]Related articles
Determination of retinal blood vessel diameters and arteriovenous ratios in systemic hypertension: comparison of different calculation formulae.
Hemminki V, Kähönen M, Tuomisto MT, Turjanmaa V, Uusitalo H.
Graefes Arch Clin Exp Ophthalmol. 2007 Jan;245(1):8-17. Epub 2006 Jul 11.PMID: 16832652 [PubMed - indexed for MEDLINE]Related articles
Reliability of computer-assisted retinal vessel measurementin a population.
Sherry LM, Wang JJ, Rochtchina E, Wong T, Klein R, Hubbard L, Mitchell P.
Clin Experiment Ophthalmol. 2002 Jun;30(3):179-82.PMID: 12010210 [PubMed - indexed for MEDLINE]Related articles
Filter your results:
Your browsing activity is empty.
Activity recording is turned off.
Turn recording back on
» See more...