Comparison of Kinetic Models Applied for Transport Description in Polymer Inclusion Membranes

Membranes (Basel). 2023 Feb 16;13(2):236. doi: 10.3390/membranes13020236.

Abstract

Five mathematical models for transport description in polymer inclusion membranes (PIMs) were presented and compared via regression analysis. The applicability of the models was estimated through the examination of experimental data of Zn(II), Cd(II), Pb(II), and Cu(II) ions transported by typical carriers. In four kinetic models, a change in the feed and stripping solution volume was taken into account. The goodness of fit was compared using the standard error of the regression, Akaike information criterion (AIC), Bayesian (Schwarz) information criterion (BIC), and Hannan-Quinn information criterion (HQC). The randomness distribution in the data was confirmed via a nonparametric runs test. Based on these quantities, appropriate models were selected.

Keywords: kinetic models; model selection; polymer inclusion membranes.

Grants and funding

This research received no external funding.