Single- and Double-Comb Tilted Fibre Bragg Grating Refractive Index Demodulation Methods with Fourier Transform Pre-Processing

Sensors (Basel). 2022 Mar 18;22(6):2344. doi: 10.3390/s22062344.

Abstract

The development of fibre optic sensors for measuring the refractive index is related to the creation of new periodic structures and demodulation algorithms for the measured spectrum. Recently, we proposed a double-comb Tilted fibre Bragg grating (DCTFBG) structure. In this article, we analyse such a structure for measuring the refractive index in comparison to a single classical structure. Increasing the number of modes causes a significant change in the Fourier spectrum of optical spectra. For the purpose of data pre-processing, we propose the Fourier Transform as a filtering method in the frequency domain. Then, we analyse separately the band-filtered optical spectra for several frequency ranges. For quantitative analysis, we use algorithms that use quantitative changes in the transmission, i.e., the method of the envelope and the length of the spectrum contour. We propose the use of the Hilbert transform as the envelope method. The second type of algorithms used are methods determining the shift of spectrum features along the wavelength axis. The method of determining the centre of gravity of the area bounded by the envelope and the maximum of the second derivative of the smoothed cumulative spectrum contour length is proposed here. Using the developed methods, the measurement resolution was achieved at the level of 2 × 10-5 refractive index unit.

Keywords: Fourier transform; TFBG sensors; double comb; refractive index.