Display Settings:

Format

Send to:

Choose Destination
    BMC Bioinformatics. 2010 Apr 27;11:207.

    G-stack modulated probe intensities on expression arrays - sequence corrections and signal calibration.

    Source

    Interdisciplinary Centre for Bioinformatics, University Leipzig, Germany.

    Abstract

    BACKGROUND:

    The brightness of the probe spots on expression microarrays intends to measure the abundance of specific mRNA targets. Probes with runs of at least three guanines (G) in their sequence show abnormal high intensities which reflect rather probe effects than target concentrations. This G-bias requires correction prior to downstream expression analysis.

    RESULTS:

    Longer runs of three or more consecutive G along the probe sequence and in particular triple degenerated G at its solution end ((GGG)1-effect) are associated with exceptionally large probe intensities on GeneChip expression arrays. This intensity bias is related to non-specific hybridization and affects both perfect match and mismatch probes. The (GGG)1-effect tends to increase gradually for microarrays of later GeneChip generations. It was found for DNA/RNA as well as for DNA/DNA probe/target-hybridization chemistries. Amplification of sample RNA using T7-primers is associated with strong positive amplitudes of the G-bias whereas alternative amplification protocols using random primers give rise to much smaller and partly even negative amplitudes. We applied positional dependent sensitivity models to analyze the specifics of probe intensities in the context of all possible short sequence motifs of one to four adjacent nucleotides along the 25meric probe sequence. Most of the longer motifs are adequately described using a nearest-neighbor (NN) model. In contrast, runs of degenerated guanines require explicit consideration of next nearest neighbors (GGG terms). Preprocessing methods such as vsn, RMA, dChip, MAS5 and gcRMA only insufficiently remove the G-bias from data.

    CONCLUSIONS:

    Positional and motif dependent sensitivity models accounts for sequence effects of oligonucleotide probe intensities. We propose a positional dependent NN+GGG hybrid model to correct the intensity bias associated with probes containing poly-G motifs. It is implemented as a single-chip based calibration algorithm for GeneChips which can be applied in a pre-correction step prior to standard preprocessing.

    PMID:
    20423484
    [PubMed - indexed for MEDLINE]
    PMCID: PMC2884167
    Free PMC Article

    Images from this publication.See all images (15) Free text

    Figure 2
    Figure 13
    Figure 15
    Figure 12
    Figure 10
    Figure 9
    Figure 4
    Figure 6
    Figure 3
    Figure 14
    Figure 5
    Figure 11
    Figure 7
    Figure 1
    Figure 8

      Supplemental Content

      Click here to read Click here to read

      Chemical compound information

      See 22 citations for this compound....

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk