    Crit Care. 2010;14(2):R36. Epub 2010 Mar 16.

    Alveolar fluid clearance in healthy pigs and influence of positive end-expiratory pressure.

    Source

    Department of Intensive Care Medicine, Virgen de las Nieves University Hospital, Fuerzas Armadas, Granada, Spain. mjgardel@telefonica.net

    Abstract

    INTRODUCTION:

    The objectives were to characterize alveolar fluid clearance (AFC) in pigs with normal lungs and to analyze the effect of immediate application of positive end-expiratory pressure (PEEP).

    METHODS:

    Animals (n = 25) were mechanically ventilated and divided into four groups: small edema (SE) group, producing pulmonary edema (PE) by intratracheal instillation of 4 ml/kg of saline solution; small edema with PEEP (SE + PEEP) group, same as previous but applying PEEP of 10 cmH2O; large edema (LE) group, producing PE by instillation of 10 ml/kg of saline solution; and large edema with PEEP (LE + PEEP) group, same as LE group but applying PEEP of 10 cmH2O. AFC was estimated from differences in extravascular lung water values obtained by transpulmonary thermodilution method.

    RESULTS:

    At one hour, AFC was 19.4% in SE group and 18.0% in LE group. In the SE + PEEP group, the AFC rate was higher at one hour than at subsequent time points and higher than in the SE group (45.4% vs. 19.4% at one hour, P < 0.05). The AFC rate was also significantly higher in the LE + PEEP than in the LE group at three hours and four hours.

    CONCLUSIONS:

    In this pig model, the AFC rate is around 20% at one hour and around 50% at four hours, regardless of the amount of edema, and is increased by the application of PEEP.

    PMID:
    20233408
    [PubMed - indexed for MEDLINE]
    PMCID: PMC2887143
    Free PMC Article

    Images from this publication.See all images (4) Free text

    Figure 1
    Figure 4
    Figure 2
    Figure 3

      Supplemental Content

      Click here to read

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk