    Genet Vaccines Ther. 2005 Apr 18;3(1):2.

    Electroporation by nucleofector is the best nonviral transfection technique in human endothelial and smooth muscle cells.

    Source

    Department of Medical Genetics, Ullevål University Hospital, Oslo, Norway. nina.iversen@medisin.uio.no.

    Abstract

    BACKGROUND:

    The aim of this study was to determine the optimal non-viral transfection method for use in human smooth muscle cells (SMC) and endothelial cells (EC).

    METHODS:

    Coronary Artery (CoA) and Aortic (Ao) SMC and EC were transfected with a reporter plasmid, encoding chloramphenicol acetyltransferase type 1 (CAT), with seven different transfection reagents, two electroporation methods and a photochemical internalization (PCI) method. CAT determination provided information regarding transfection efficiency and total protein measurement was used to reflect the toxicity of each method.

    RESULTS:

    Electroporation via the nucleofector machine was the most effective method tested. It exhibited a 10 to 20 fold (for SMC and EC, respectively) increase in transfection efficiency in comparison to the lipofection method combined with acceptable toxicity. FuGene 6 and Lipofectamine PLUS were the preferred transfection reagents tested and resulted in 2 to 60 fold higher transfection efficiency in comparison to the PCI which was the least effective method.

    CONCLUSION:

    This study indicates that electroporation via the nucleofector machine is the preferred non-viral method for in vitro transfection of both human aortic and coronary artery SMC and EC. It may be very useful in gene expression studies in the field of vascular biology. Through improved gene transfer, non-viral transfer techniques may also play an increasingly important role in delivering genes to SMC and EC in relevant disease states.

    PMID:
    15836781
    [PubMed - as supplied by publisher]
    PMCID: PMC1087498
    Free PMC Article

    Images from this publication.See all images (6) Free text

    Figure 5
    Figure 2
    Figure 6
    Figure 3
    Figure 4
    Figure 1

      Supplemental Content

      Click here to read Click here to read

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk