Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies

Review published: 2010.

Bibliographic details: Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M.  Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Medicine 2010; 36(9): 1475-1483. [PubMed: 20502865]

Quality assessment

This review concluded that changes in cardiac output induced by passive leg raising could reliably predict fluid responsiveness regardless of ventilation mode, underlying cardiac rhythm, and technique of measurement. Weaknesses in the review process and unclear data quality mean that this conclusion should be interpreted cautiously. Full critical summary

Abstract

PURPOSE: To systematically review the published evidence on the ability of passive leg raising-induced changes in cardiac output (PLR-cCO) and in arterial pulse pressure (PLR-cPP) to predict fluid responsiveness.

METHODS: MEDLINE, EMBASE and the Cochrane Database of Systematic Reviews were screened. Clinical trials on human adults published as full-text articles in indexed journals were included. Two authors independently used a standardized form to extract data about study characteristics and results. Study quality was assessed by using the QUADAS scale.

RESULTS: Nine articles including a total of 353 patients were included in the final analysis. Data are reported as point estimate (95% confidence intervals). The pooled sensitivity and specificity of PLR-cCO were 89.4% (84.1-93.4%) and 91.4% (85.9-95.2%) respectively. Diagnostic odds ratio was 89.0 (40.2-197.3). The pooled area under the receiver operating characteristics curve (AUC) was 0.95 (0.92-0.97). The pooled correlation coefficient r between baseline value of PLR-cCO and CO increase after fluid load was 0.81 (0.75-0.86). The pooled difference in mean PLR-cCO values between responders and non-responders was 17.7% (13.6-21.8%). No significant differences were identified between patients adapted to ventilator versus those with inspiratory efforts nor between patients in sinus rhythm versus those with arrhythmias. The pooled AUC for PLR-cPP was 0.76 (0.67-0.86) and was significantly lower than the AUC for PLR-cCO (p < 0.001). The pooled difference in mean PLR-cPP values between responders and non-responders was 10.3% (6.5-14.1%).

CONCLUSIONS: Passive leg raising-induced changes in cardiac output can reliably predict fluid responsiveness regardless of ventilation mode and cardiac rhythm. PLR-cCO has a significantly higher predictive value than PLR-cPP.

CRD has determined that this article meets the DARE scientific quality criteria for a systematic review.