Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1973 2
1975 1
1978 1
1980 2
1981 1
1985 1
1986 1
1988 2
1989 1
1992 1
1993 3
1998 3
1999 2
2000 1
2001 3
2002 2
2003 5
2004 6
2005 9
2006 10
2007 7
2008 12
2009 6
2010 11
2011 16
2012 16
2013 15
2014 18
2015 23
2016 18
2017 23
2018 16
2019 12
2020 21
2021 14
2022 16
2023 12
2024 8

Text availability

Article attribute

Article type

Publication date

Search Results

292 results

Results by year

Filters applied: . Clear all
Page 1
Effects of Vibration and Non-Vibration Foam Rolling on Recovery after Exercise with Induced Muscle Damage.
Romero-Moraleda B, González-García J, Cuéllar-Rayo Á, Balsalobre-Fernández C, Muñoz-García D, Morencos E. Romero-Moraleda B, et al. J Sports Sci Med. 2019 Feb 11;18(1):172-180. eCollection 2019 Mar. J Sports Sci Med. 2019. PMID: 30787665 Free PMC article. Clinical Trial.
We aimed to compare the effects between non-vibration foam rolling (NVFR) and vibration foam rolling (VFR) on visual analogic scale (VAS), pressure pain threshold (PPT), oxygen saturation (SmO2), countermovement jump (CMJ) and hip and knee range of movement (ROM) af …
We aimed to compare the effects between non-vibration foam rolling (NVFR) and vibration foam rolling (VFR) on visual analogic …
Cam-based vibration-counter-balanced laser-induced fluorescence scanner for multiplexed capillary detection.
Li G, Wang S, Zhu Z, Chen A, Liu S. Li G, et al. Talanta. 2019 Jun 1;198:398-403. doi: 10.1016/j.talanta.2019.01.128. Epub 2019 Feb 10. Talanta. 2019. PMID: 30876578
A linear LIF scanner works well for flat parallel capillary arrays, but motor accelerations/decelerations (for direction changes) and scanning head vibrations introduce high instrumental noises. The number of capillaries that can be scanned by a linear scanner is limited b …
A linear LIF scanner works well for flat parallel capillary arrays, but motor accelerations/decelerations (for direction changes) and scanni …
Effect of whole-body vibration on neuromuscular performance: A literature review.
Alam MM, Khan AA, Farooq M. Alam MM, et al. Work. 2018;59(4):571-583. doi: 10.3233/WOR-182699. Work. 2018. PMID: 29733043 Review.
RESULT: Whole-body vibration, along with additional exercise training, has a potential to induce substantial improvement in neuromuscular performance. CONCLUSION: Whole-body vibration can bring about improvement in muscles strength, power, and flexibility. ...
RESULT: Whole-body vibration, along with additional exercise training, has a potential to induce substantial improvement in neuromusc …
A Vibration Device to Control Injection Discomfort.
Shaefer JR, Lee SJ, Anderson NK. Shaefer JR, et al. Compend Contin Educ Dent. 2017 Jun;38(6):e5-e8. Compend Contin Educ Dent. 2017. PMID: 28586233 Clinical Trial.
Pain from local anesthesia injections can be reduced by distraction and counter-stimulation techniques. This study investigated the DentalVibe Injection Comfort System (third-generation, DV3), developed to lessen anesthesia pain through pulsed vibration, a form of …
Pain from local anesthesia injections can be reduced by distraction and counter-stimulation techniques. This study investigated the D …
Smart Active Vibration Control System of a Rotary Structure Using Piezoelectric Materials.
Hashemi A, Jang J, Hosseini-Hashemi S. Hashemi A, et al. Sensors (Basel). 2022 Jul 29;22(15):5691. doi: 10.3390/s22155691. Sensors (Basel). 2022. PMID: 35957246 Free PMC article.
The proposed method maps the WT blade to a Euler-Bernoulli beam under the same conditions to find the blade's vibration and dynamic responses by solving analytical vibration solutions of the Euler-Bernoulli beam. The governing equations of the beam with PZT patches …
The proposed method maps the WT blade to a Euler-Bernoulli beam under the same conditions to find the blade's vibration and dynamic r …
Microbial Brazil nut effect.
Srivastava A, Kikuchi K, Ishikawa T. Srivastava A, et al. Soft Matter. 2021 Dec 1;17(46):10428-10436. doi: 10.1039/d1sm01327k. Soft Matter. 2021. PMID: 34699580
The Brazil nut effect (BNE) is a counter-intuitive process of segregation of a large object inside a vibrated granular medium (GM), which has been studied widely by subjecting GMs to various kinds of shears and vibrations. ...
The Brazil nut effect (BNE) is a counter-intuitive process of segregation of a large object inside a vibrated granular medium …
Vibration sensing the mammalian way: an artificial Pacinian corpuscle.
Lane S, Barrett-Snyder K, Lazarus N, Alberts WCK, Hanrahan B. Lane S, et al. Bioinspir Biomim. 2020 May 11;15(4):046001. doi: 10.1088/1748-3190/ab7ab6. Bioinspir Biomim. 2020. PMID: 32106099
A vibration sensor is presented mimicking the structure of the Pacinian corpuscle. A multi-step casting process is used to create a 5 mm diameter sensor with a liquid metal core, elastomer dielectric, and graphite counter electrode creating a spherical capacitive se …
A vibration sensor is presented mimicking the structure of the Pacinian corpuscle. A multi-step casting process is used to create a 5 …
The effect of vibratory stimulus on pain perception during intraoral local anesthesia administration in children: a systematic review and meta-analysis.
Tirupathi SP, Rajasekhar S. Tirupathi SP, et al. J Dent Anesth Pain Med. 2020 Dec;20(6):357-365. doi: 10.17245/jdapm.2020.20.6.357. Epub 2020 Dec 28. J Dent Anesth Pain Med. 2020. PMID: 33409364 Free PMC article. Review.
BACKGROUND: To evaluate the effectiveness of vibration as a counter-stimulatory measure in reducing subjective pain due to local anesthesia administration in children. ...RESULTS: A total of seven studies involving 376 children aged 5-17 years were included in the s …
BACKGROUND: To evaluate the effectiveness of vibration as a counter-stimulatory measure in reducing subjective pain due to loc …
Stability of a liquid bridge under vibration.
Benilov ES. Benilov ES. Phys Rev E. 2016 Jun;93(6):063118. doi: 10.1103/PhysRevE.93.063118. Epub 2016 Jun 27. Phys Rev E. 2016. PMID: 27415369
We examine the stability of a vertical liquid bridge between two vertically vibrating, coaxial disks. Assuming that the vibration amplitude and period are much smaller than the mean distance between the disks and the global timescale, respectively, we employ the met …
We examine the stability of a vertical liquid bridge between two vertically vibrating, coaxial disks. Assuming that the vibration
292 results