Format
Items per page
Sort by

Send to:

Choose Destination

Search results

Items: 1 to 20 of 46

1.

[Short-term effects on reconstruction of Paprosky type III severe acetabulum bone defect with tantalum metal block].

Tang ZY, Li P, Cha XF.

Zhongguo Gu Shang. 2015 Dec;28(12):1137-40. Chinese.

PMID:
26911125
2.

Trabecular Metal Use in Paprosky Type 2 and 3 Acetabular Defects: 5-Year Follow-Up.

Clement RG, Ray AG, MacDonald DJ, Wade FA, Burnett R, Moran M.

J Arthroplasty. 2016 Apr;31(4):863-7. doi: 10.1016/j.arth.2015.10.033. Epub 2015 Nov 10.

PMID:
26711861
3.

Porous Tantalum Buttress Augments for Severe Acetabular Posterior Column Deficiency.

Meneghini RM, Hull JR, Russo GS, Lieberman JR, Jiranek WA.

Surg Technol Int. 2015 Nov;27:240-4.

PMID:
26680404
4.
5.

Is tantalum protective against infection in revision total hip arthroplasty?

Tokarski AT, Novack TA, Parvizi J.

Bone Joint J. 2015 Jan;97-B(1):45-9. doi: 10.1302/0301-620X.97B1.34236.

PMID:
25568412
6.

Management of pelvic discontinuity in revision total hip arthroplasty: a review of the literature.

Abdelnasser MK, Klenke FM, Whitlock P, Khalil AM, Khalifa YE, Ali HM, Siebenrock KA.

Hip Int. 2015 Mar-Apr;25(2):120-6. doi: 10.5301/hipint.5000201. Epub 2014 Nov 6. Review.

PMID:
25385048
7.

Acetabular distraction: an alternative approach to pelvic discontinuity in failed total hip replacement.

Brown NM, Hellman M, Haughom BH, Shah RP, Sporer SM, Paprosky WG.

Bone Joint J. 2014 Nov;96-B(11 Supple A):73-7. doi: 10.1302/0301-620X.96B11.34316. Review.

PMID:
25381413
8.

Metallosis and elevated serum levels of tantalum following failed revision hip arthroplasty--a case report.

Babis GC, Stavropoulos NA, Sasalos G, Ochsenkuehn-Petropoulou M, Megas P.

Acta Orthop. 2014 Dec;85(6):677-80. doi: 10.3109/17453674.2014.950816. Epub 2014 Aug 20. No abstract available.

9.

Periacetabular bone metabolism following hip revision surgery. PET-based evaluation of allograft osteointegration.

Bernstein P, Beuthien-Baumann B, Kotzerke J, Hofheinz F, Zessin J, Stiehler M, Günther KP.

Nuklearmedizin. 2014 Aug 6;53(4):147-54. doi: 10.3413/Nukmed-0607-13-06. Epub 2014 Feb 28.

PMID:
24577419
10.

Proximal femoral reconstruction after aseptic loosening following proximal femoral replacement for Ewing sarcoma: a case report with one-year follow-up.

Schoof B, Jakobs O, Gehrke T, Gebauer M.

Hip Int. 2014 Jan-Feb;24(1):103-7. doi: 10.5301/hipint.5000092. Epub 2014 Jan 29.

PMID:
24474409
11.

Outcome of porous tantalum acetabular components for Paprosky type 3 and 4 acetabular defects.

Batuyong ED, Brock HS, Thiruvengadam N, Maloney WJ, Goodman SB, Huddleston JI.

J Arthroplasty. 2014 Jun;29(6):1318-22. doi: 10.1016/j.arth.2013.12.002. Epub 2013 Dec 7.

PMID:
24405625
12.

Early results of trabecular metal augment for acetabular reconstruction in revision hip arthroplasty.

Elganzoury I, Bassiony AA.

Acta Orthop Belg. 2013 Oct;79(5):530-5.

PMID:
24350514
13.

Porous tantalum shells and augments for acetabular cup revisions.

Moličnik A, Hanc M, Rečnik G, Krajnc Z, Rupreht M, Fokter SK.

Eur J Orthop Surg Traumatol. 2014 Aug;24(6):911-7. doi: 10.1007/s00590-013-1354-3. Epub 2013 Nov 16.

PMID:
24241214
14.

Use of porous tantalum for acetabular reconstruction in revision hip arthroplasty.

Issack PS.

J Bone Joint Surg Am. 2013 Nov 6;95(21):1981-7. doi: 10.2106/JBJS.L.01313. Review. Erratum in: J Bone Joint Surg Am. 2013 Nov 6;95(21):1987. J Bone Joint Surg Am. 2013 Dec 18;95(24):e196.

PMID:
24196469
15.

Options for managing severe acetabular bone loss in revision hip arthroplasty. A systematic review.

Jain S, Grogan RJ, Giannoudis PV.

Hip Int. 2014 Mar-Apr;24(2):109-22. doi: 10.5301/hipint.5000101. Epub 2013 Oct 30. Review.

PMID:
24186672
16.

Acetabular revision in THA using tantalum augments combined with impaction bone grafting.

Gehrke T, Bangert Y, Schwantes B, Gebauer M, Kendoff D.

Hip Int. 2013 Jul-Aug;23(4):359-65. doi: 10.5301/hipint.5000044. Epub 2013 Jun 17.

PMID:
23813166
17.

High complication rate after revision of large-head metal-on-metal total hip arthroplasty.

Munro JT, Masri BA, Duncan CP, Garbuz DS.

Clin Orthop Relat Res. 2014 Feb;472(2):523-8. doi: 10.1007/s11999-013-2979-6.

18.

Acetabular distraction: an alternative for severe defects with chronic pelvic discontinuity?

Sporer SM, Bottros JJ, Hulst JB, Kancherla VK, Moric M, Paprosky WG.

Clin Orthop Relat Res. 2012 Nov;470(11):3156-63. doi: 10.1007/s11999-012-2514-1.

19.

Histological ex vivo analysis of retrieved human tantalum augmentations.

Breer S, Hahn M, Kendoff D, Krause M, Koehne T, Haasper C, Gehrke T, Amling M, Gebauer M.

Int Orthop. 2012 Nov;36(11):2269-74. doi: 10.1007/s00264-012-1640-4. Epub 2012 Aug 15.

20.

[Porous tantalum modular cups in revision hip arthroplasty].

Markuszewski J, Wierusz-Kozłowska M, Woźniak W, Łapaj Ł, Kokoszka P.

Chir Narzadow Ruchu Ortop Pol. 2011 Jul-Aug;76(4):197-200. Polish.

PMID:
22235641
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Loading ...
Write to the Help Desk