Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1965 1
1970 2
1971 1
1972 2
1973 2
1974 1
1975 1
1976 3
1978 2
1979 3
1981 2
1982 3
1983 3
1984 2
1986 3
1989 3
1990 1
1991 3
1992 2
1993 1
1994 2
1996 1
1998 1
1999 1
2000 3
2001 1
2002 1
2003 1
2004 2
2006 3
2007 8
2008 2
2009 2
2010 3
2011 5
2012 2
2013 4
2014 4
2015 1
2016 3
2017 3
2018 1
2019 3
2020 3
2021 2
2022 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

103 results

Results by year

Filters applied: . Clear all
Page 1
Near-infrared laser thermal conjunctivoplasty.
Yang J, Chandwani R, Gopinatth V, Boyce T, Pflugfelder SC, Huang D, Liu G. Yang J, et al. Sci Rep. 2018 Mar 1;8(1):3863. doi: 10.1038/s41598-018-22204-0. Sci Rep. 2018. PMID: 29497112 Free PMC article.
The current solutions to this disease include either surgical excision in the operating room, or thermoreduction of the loose tissue with hot wire in the clinic. We developed a near-infrared laser thermal conjunctivoplasty system. ...
The current solutions to this disease include either surgical excision in the operating room, or thermoreduction of the loose tissue with …
A pilot study of hot-wire, ultrasonic and wedge-bellows spirometer inter- and intra-variability.
Aardal ME, Svendsen LL, Lehmann S, Eagan TM, Haaland I. Aardal ME, et al. BMC Res Notes. 2017 Oct 10;10(1):497. doi: 10.1186/s13104-017-2825-0. BMC Res Notes. 2017. PMID: 29017612 Free PMC article.
Significant differences were found between hot-wire and ultrasonic and between wedge-bellows and ultrasonic spirometers for FVC and FEV1, and between hot-wire and wedge-bellows spirometers for FVC but not for FEV1. ...In conclusion, the pilot study sho …
Significant differences were found between hot-wire and ultrasonic and between wedge-bellows and ultrasonic spirometers for FV …
Flow measurement in mechanical ventilation: a review.
Schena E, Massaroni C, Saccomandi P, Cecchini S. Schena E, et al. Med Eng Phys. 2015 Mar;37(3):257-64. doi: 10.1016/j.medengphy.2015.01.010. Epub 2015 Feb 7. Med Eng Phys. 2015. PMID: 25659299 Review.
Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable orifice meters, hot wire anemometers, and ultrasonic flowmeters. This paper provides an overview of these sensors. ...
Therefore, mechanical ventilators are equipped with only the following kinds of flowmeters: linear pneumotachographs, fixed and variable ori …
Evaluation of a hot-wire hair removal device compared to razor shaving.
Biesman BS. Biesman BS. Lasers Surg Med. 2013 Jul;45(5):283-95. doi: 10.1002/lsm.22144. Epub 2013 Jun 5. Lasers Surg Med. 2013. PMID: 23740688 Clinical Trial.
BACKGROUND AND OBJECTIVES: We describe a blinded, controlled, prospective clinical study of a hot-wire device promoted for hair removal and the reduction or delay of hair regrowth (no!...In terms of hair characteristics, no difference in hair color or hair thickness …
BACKGROUND AND OBJECTIVES: We describe a blinded, controlled, prospective clinical study of a hot-wire device promoted for hai …
[Hot-wire spirometer].
Yoshiya I, Takemura M, Nakajima T, Nagai I, Jitsukawa S. Yoshiya I, et al. Kokyu To Junkan. 1973 Mar;21(3):225-9. Kokyu To Junkan. 1973. PMID: 4734988 Japanese. No abstract available.
A High-Temperature Transient Hot-Wire Thermal Conductivity Apparatus for Fluids.
Perkins RA, Roder HM, Nieto de Castro CA. Perkins RA, et al. J Res Natl Inst Stand Technol. 1991 May-Jun;96(3):247-269. doi: 10.6028/jres.096.014. J Res Natl Inst Stand Technol. 1991. PMID: 28184114 Free PMC article.
A new apparatus for measuring both the thermal conductivity and thermal diffusivity of fluids at temperatures from 220 to 775 K at pressures to 70 MPa is described. The instrument is based on the step-power-forced transient hot-wire technique. ...These new da …
A new apparatus for measuring both the thermal conductivity and thermal diffusivity of fluids at temperatures from 220 to 775 K at pressures …
Hot-wire anemometer for spirography.
Plakk P, Liik P, Kingisepp PH. Plakk P, et al. Med Biol Eng Comput. 1998 Jan;36(1):17-21. doi: 10.1007/BF02522852. Med Biol Eng Comput. 1998. PMID: 9614743
The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is st …
The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating pri …
A bidirectional respiratory flowmeter using the hot-wire principle.
Yoshiya I, Nakajima T, Nagai I, Jitsukawa S. Yoshiya I, et al. J Appl Physiol. 1975 Feb;38(2):360-5. doi: 10.1152/jappl.1975.38.2.360. J Appl Physiol. 1975. PMID: 1120766
We have devised a bidirectional respiratory flowmeter using the hot-wire principle. The flow-direction sensor consists of a pair of tungsten wires strung parallel to the platinum hot-wire one on each side of the platinum wire. ...The difference in resi …
We have devised a bidirectional respiratory flowmeter using the hot-wire principle. The flow-direction sensor consists of a pa …
A hot-wire probe for thermal measurements of nanowires and nanotubes inside a transmission electron microscope.
Dames C, Chen S, Harris CT, Huang JY, Ren ZF, Dresselhaus MS, Chen G. Dames C, et al. Rev Sci Instrum. 2007 Oct;78(10):104903. doi: 10.1063/1.2785848. Rev Sci Instrum. 2007. PMID: 17979450
A hot wire probe has been developed for use inside a transmission electron microscope to measure the thermal resistance of individual nanowires, nanotubes, and their contacts. ...Detailed thermal analysis shows that for best sensitivity, the thermal resistance of th …
A hot wire probe has been developed for use inside a transmission electron microscope to measure the thermal resistance of ind …
103 results