Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1987 4
1988 5
1989 11
1990 16
1991 12
1992 11
1993 6
1994 6
1995 12
1996 9
1997 7
1998 5
1999 9
2000 7
2001 5
2002 8
2003 5
2004 14
2005 4
2006 2
2007 3
2008 1
2009 1
2014 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

164 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for hemophan
Search for hemophage instead (3 results)
Influence of polysulfone and hemophan hemodialysis membranes on phagocytes.
Kubala L, Cíz M, Soska V, Cerný J, Lojek A. Kubala L, et al. Gen Physiol Biophys. 2002 Dec;21(4):367-80. Gen Physiol Biophys. 2002. PMID: 12693710 Free article.
Further decrease in ROS production and an increase in CD11b expression were observed especially in patients after hemophan hemodialysis. Decreased ROS production and increased CD11b expression were observed also after incubation of HL-60 cells with hemophan membrane …
Further decrease in ROS production and an increase in CD11b expression were observed especially in patients after hemophan hemodialys …
Hemodialysis using heparin-bound Hemophan in patients at risk of bleeding.
Lee KB, Kim B, Lee YH, Yoon SJ, Kang WH, Huh W, Kim DJ, Oh HY, Kim YG. Lee KB, et al. Nephron Clin Pract. 2004;97(1):c5-10. doi: 10.1159/000077589. Nephron Clin Pract. 2004. PMID: 15153761
BACKGROUND/AIMS: Since heparin can bind to Hemophan, hemodialysis using heparin-bound Hemophan (HBH-HD) could be a useful modality in patients at risk of bleeding. We designed a simplified heparin binding technique and assessed the safety and efficiency of HBH-HD. M …
BACKGROUND/AIMS: Since heparin can bind to Hemophan, hemodialysis using heparin-bound Hemophan (HBH-HD) could be a useful moda …
Membranes for dialysis.
Klinkmann H, Vienken J. Klinkmann H, et al. Nephrol Dial Transplant. 1995;10 Suppl 3:39-45. doi: 10.1093/ndt/10.supp3.39. Nephrol Dial Transplant. 1995. PMID: 7494613 Review.
Of central interest for membrane development and application is the question of how these membranes can be sterilized, as a series of patient adverse reactions has been attributed to the dialyser sterilization procedures. Apart from the cellulosic membranes Cuprophan and Hemop
Of central interest for membrane development and application is the question of how these membranes can be sterilized, as a series of patien …
Hemophan versus hemophan--a philippic against the suggestion of constant membrane quality.
Kolb G, Müller T, Höffken H, Joseph K, Lange H, Havemann K. Kolb G, et al. Biomater Artif Cells Immobilization Biotechnol. 1992;20(5):1233-48. doi: 10.3109/10731199209117349. Biomater Artif Cells Immobilization Biotechnol. 1992. PMID: 1333828
All statements referring to biocompatibility of dialyzers depend on the suggestion of a constant and reproducible structure of the investigated membrane material. The data presented here strike this concepts in case of hemophane. Two commercially available hemophane
All statements referring to biocompatibility of dialyzers depend on the suggestion of a constant and reproducible structure of the investiga …
Formation of thrombin-antithrombin III complex using polyamide and hemophan dialyzers.
Schultze G, Hollmann S, Sinah P. Schultze G, et al. Int J Artif Organs. 1992 Jun;15(6):370-3. Int J Artif Organs. 1992. PMID: 1639530
For further evaluation of the thrombogenicity of a polyamide (P) and a Hemophan (H) hollow-fibre dialyzer a cross-over study was done in ten stable patients on maintenance hemodialysis. ...
For further evaluation of the thrombogenicity of a polyamide (P) and a Hemophan (H) hollow-fibre dialyzer a cross-over study was done …
Improved biocompatibility by modified cellulosic membranes: the case of hemophan.
Lucchi L, Bonucchi D, Acerbi MA, Cappelli G, Spattini A, Innocenti M, Castellani A, Lusvarghi E. Lucchi L, et al. Artif Organs. 1989 Oct;13(5):417-21. doi: 10.1111/j.1525-1594.1989.tb01550.x. Artif Organs. 1989. PMID: 2803049
The authors compared the biocompatibility of cuprophan (CU), cellulose acetate (CA), and hemophan (HE), evaluating both in vitro and in vivo polymorphonuclear leukocyte (PMN) oxidative metabolism activation by resting chemiluminescence and complement activation by C3a; in …
The authors compared the biocompatibility of cuprophan (CU), cellulose acetate (CA), and hemophan (HE), evaluating both in vitro and …
Anticoagulation during haemodialysis in patients at high-risk of bleeding.
Kim YG. Kim YG. Nephrology (Carlton). 2003 Oct;8 Suppl:S23-7. doi: 10.1046/j.1440-1797.8.s.3.x. Nephrology (Carlton). 2003. PMID: 15012687 Review.
Haemodialysis using heparin-bound Hemophan has been reported to be a possible modality for patients at risk of bleeding. We designed more simplified heparin binding technique and have performed haemodialysis using heparin-bound Hemophan in patients at risk of bleedi …
Haemodialysis using heparin-bound Hemophan has been reported to be a possible modality for patients at risk of bleeding. We designed …
[Anticoagulant].
Shibamoto T, Akiba T. Shibamoto T, et al. Nihon Rinsho. 1991 Dec;49 Suppl:175-83. Nihon Rinsho. 1991. PMID: 1808251 Japanese. No abstract available.
Enhanced biocompatibility with a new cellulosic membrane: Cuprophan versus Hemophan.
Schaefer RM, Hörl WH, Kokot K, Heidland A. Schaefer RM, et al. Blood Purif. 1987;5(4):262-7. doi: 10.1159/000169475. Blood Purif. 1987. PMID: 3426830
Recently, a new type of modified cellulosic membrane (Hemophan) has been made available for the first clinical trials. In contrast to cellulose acetate membranes only about 5% of the hydroxyl groups of cellulose are substituted by tertiary amino groups. ...All these differ …
Recently, a new type of modified cellulosic membrane (Hemophan) has been made available for the first clinical trials. In contrast to …
164 results