Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1994 1
1999 1
2002 1
2010 1
2013 1
2014 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

6 results

Results by year

Filters applied: . Clear all
Page 1
Effect of mandibular tori on glottic exposure during simulated suspension microlaryngoscopy.
Best SR, Kobler JB, Friedman AD, Barbu AM, Zeitels SM, Burns JA. Best SR, et al. Ann Otol Rhinol Laryngol. 2014 Mar;123(3):188-94. doi: 10.1177/0003489414522967. Ann Otol Rhinol Laryngol. 2014. PMID: 24633945
The glottiscope angle relative to the horizontal plane was measured for each condition. ...Increasing the thyromental distance increased the posterior glottiscope tip displacement regardless of torus size or location. The glottiscope angle increased with larg …
The glottiscope angle relative to the horizontal plane was measured for each condition. ...Increasing the thyromental distance increa …
Universal modular glottiscope system: the evolution of a century of design and technique for direct laryngoscopy.
Zeitels SM. Zeitels SM. Ann Otol Rhinol Laryngol Suppl. 1999 Sep;179:2-24. doi: 10.1177/00034894991080s901. Ann Otol Rhinol Laryngol Suppl. 1999. PMID: 10527286
The Pro/Engineer and Pro/Mechanica computer programs were used to model the universal modular glottiscope. This new laryngoscope comprises a plurality of specially designed examining tubes that are bivalved proximally to improve utilization of hand instrumentation, and for …
The Pro/Engineer and Pro/Mechanica computer programs were used to model the universal modular glottiscope. This new laryngoscope comp …
[Performance of the glottiscopes: a randomized comparative study on difficult intubation simulation manikin].
Sudrial J, Abdi W, Amathieu R, Luis D, Jabre P, Le Roux B, Slavov V, Kamoun W, Avenel A, Sebbah JL, Combes X, Dhonneur G. Sudrial J, et al. Ann Fr Anesth Reanim. 2010 May;29(5):347-53. doi: 10.1016/j.annfar.2009.12.028. Epub 2010 Mar 29. Ann Fr Anesth Reanim. 2010. PMID: 20347564 Clinical Trial. French.
STUDY DESIGN: prospective with the airway devices proposed in a randomly assigned order. MATERIALS AND METHOD: Forty-two physicians, naive to glottiscope handling accepted participating this study after the learning curve of each airway device was completed. ...
STUDY DESIGN: prospective with the airway devices proposed in a randomly assigned order. MATERIALS AND METHOD: Forty-two physicians, naive t …
[Diagnosis and therapy of diseases of the larynx in the history of medicine].
Feldmann H. Feldmann H. Laryngorhinootologie. 2002 Jan;81(1):46-55. doi: 10.1055/s-2002-20113. Laryngorhinootologie. 2002. PMID: 11845402 German.
His attempts were continued by Avery in London in 1840 with special view to the larynx but were not successful. Babington in London in 1829 constructed a glottiscope combining an angled mirror with a depressor for the tongue. ...
His attempts were continued by Avery in London in 1840 with special view to the larynx but were not successful. Babington in London in 1829 …
"External counterpressure" and "internal distention" for optimal laryngoscopic exposure of the anterior glottal commissure.
Zeitels SM, Vaughan CW. Zeitels SM, et al. Ann Otol Rhinol Laryngol. 1994 Sep;103(9):669-75. doi: 10.1177/000348949410300902. Ann Otol Rhinol Laryngol. 1994. PMID: 8085725
Internal distention was achieved by placing the largest-lumen glottiscope possible between the endotracheal tube and the infrapetiole region. ...
Internal distention was achieved by placing the largest-lumen glottiscope possible between the endotracheal tube and the infrapetiole …