Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1898 1
1952 1
1953 1
1955 1
1957 1
1959 1
1961 1
1962 1
1963 2
1964 3
1965 4
1966 3
1967 1
1968 3
1969 4
1970 1
1971 5
1972 1
1973 2
1974 2
1975 8
1976 10
1977 13
1978 10
1979 11
1980 18
1981 19
1982 17
1983 25
1984 14
1985 14
1986 21
1987 27
1988 25
1989 26
1990 21
1991 19
1992 32
1993 23
1994 22
1995 16
1996 20
1997 23
1998 26
1999 27
2000 13
2001 20
2002 21
2003 28
2004 30
2005 33
2006 44
2007 35
2008 28
2009 38
2010 27
2011 44
2012 54
2013 42
2014 52
2015 40
2016 40
2017 48
2018 55
2019 53
2020 62
2021 74
2022 68
2023 58
2024 17

Text availability

Article attribute

Article type

Publication date

Search Results

1,433 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for fluorometer
Your search for floodometer retrieved no results
Filter Fluorometer Calibration Without the Fluorometer.
English CM, Kitzhaber ZB, Sanim KRI, Vitzilaios N, Hodgson ME, Richardson TL, Myrick ML. English CM, et al. Appl Spectrosc. 2023 Sep;77(9):1053-1063. doi: 10.1177/00037028231181593. Epub 2023 Jun 23. Appl Spectrosc. 2023. PMID: 37350765
We recently described a lightweight, low-power, waterproof filter fluorometer using a 180 backscatter geometry for chlorophyll-a (chl-a) detection. ...
We recently described a lightweight, low-power, waterproof filter fluorometer using a 180 backscatter geometry for chlorophyll-a (chl …
Photosynthesis: basics, history and modelling.
Stirbet A, Lazár D, Guo Y, Govindjee G. Stirbet A, et al. Ann Bot. 2020 Sep 14;126(4):511-537. doi: 10.1093/aob/mcz171. Ann Bot. 2020. PMID: 31641747 Free PMC article. Review.
Different mathematical models have been used to examine current theories on diverse photosynthetic processes; these have been validated through simulation(s) of available experimental data, such as chlorophyll a fluorescence induction, measured with fluorometers using cont …
Different mathematical models have been used to examine current theories on diverse photosynthetic processes; these have been validated thro …
Spectrophotometric and colorimetric determination of protein concentration.
Simonian MH, Smith JA. Simonian MH, et al. Curr Protoc Mol Biol. 2006 Nov;Chapter 10:Unit 10.1A. doi: 10.1002/0471142727.mb1001as76. Curr Protoc Mol Biol. 2006. PMID: 18265371 Review.
Both methods can be used to quantitate total protein in crude lysates and purified or partially purified protein. Use of a spectrofluorometer or a filter fluorometer to measure the intrinsic fluorescence emission of a sample solution is also described. ...
Both methods can be used to quantitate total protein in crude lysates and purified or partially purified protein. Use of a spectrofluoromete …
Chlorophyll Fluorometer for Intelligent Water Sampling by a Small Uncrewed Aircraft System (sUAS).
English CM, Kitzhaber ZB, Sanim KRI, Kalaitzakis M, Kosaraju B, Pinckney JL, Hodgson ME, Vitzilaios NI, Richardson TL, Myrick ML. English CM, et al. Appl Spectrosc. 2023 Jan;77(1):94-105. doi: 10.1177/00037028221126748. Epub 2022 Oct 14. Appl Spectrosc. 2023. PMID: 36065908
The fluorometer uses a 450 nm laser modulated at 10 Hz for excitation and a standard photodiode and transimpedance amplifier for the detection of fluorescence. Additional detectors are available for measuring laser intensity and light scattering. Control of the fluorome
The fluorometer uses a 450 nm laser modulated at 10 Hz for excitation and a standard photodiode and transimpedance amplifier for the …
Fluorometer Control and Readout Using an Arduino Nano 33 BLE Sense Board.
Kitzhaber ZB, English CM, Sanim KRI, Kalaitzakis M, Kosaraju B, Hodgson ME, Vitzilaios N, Richardson TL, Myrick ML. Kitzhaber ZB, et al. Appl Spectrosc. 2023 Feb;77(2):220-224. doi: 10.1177/00037028221128800. Epub 2022 Oct 5. Appl Spectrosc. 2023. PMID: 36197285
We describe the control and interfacing of a fluorometer designed for aerial drone-based measurements of chlorophyll-a using an Arduino Nano 33 BLE Sense board. ...The fluorometer was integrated into a small Uncrewed Aircraft System (sUAS) for automated water sampli …
We describe the control and interfacing of a fluorometer designed for aerial drone-based measurements of chlorophyll-a using an Ardui …
Portable Near-Infrared Fluorometer for a Liposomal Blood Lactate Assay.
Guirguis N, Machuca-Parra AI, Matoori S. Guirguis N, et al. ACS Pharmacol Transl Sci. 2023 May 5;6(6):907-912. doi: 10.1021/acsptsci.3c00055. eCollection 2023 Jun 9. ACS Pharmacol Transl Sci. 2023. PMID: 37325442 Free PMC article.
For translation to the point of care, the liposomal lactate assay needs to be combined with a small portable NIR fluorometer. Portable NIR fluorometers were successfully used for the analysis of skin and soil samples, but reports for blood metabolite assays are scar …
For translation to the point of care, the liposomal lactate assay needs to be combined with a small portable NIR fluorometer. Portabl …
Trends in fabrication, data gathering, validation, and application of molecular fluorometer and spectrofluorometer.
Pascua JAA, Prado AJA, Solis BRB, Cid-Andres AP, Cambiador CJB. Pascua JAA, et al. Spectrochim Acta A Mol Biomol Spectrosc. 2019 Sep 5;220:116837. doi: 10.1016/j.saa.2019.02.061. Epub 2019 Feb 21. Spectrochim Acta A Mol Biomol Spectrosc. 2019. PMID: 31195242 Review.
There have been various methods used in applications of spectrofluorometer, but some were costly, time consuming or complicated for routine analysis, creating barrier for students to understand the basic concepts of fluorescence. This review focuses on the different fluoromete
There have been various methods used in applications of spectrofluorometer, but some were costly, time consuming or complicated for routine …
RNA quantitation by fluorescence-based solution assay: RiboGreen reagent characterization.
Jones LJ, Yue ST, Cheung CY, Singer VL. Jones LJ, et al. Anal Biochem. 1998 Dec 15;265(2):368-74. doi: 10.1006/abio.1998.2914. Anal Biochem. 1998. PMID: 9882416
The RiboGreen assay allows detection of as little as 1.0 ng/ml RNA in a standard fluorometer, filter fluorometer, or fluorescence microplate reader-surpassing the sensitivity achieved with ethidium bromide by 200-fold. ...
The RiboGreen assay allows detection of as little as 1.0 ng/ml RNA in a standard fluorometer, filter fluorometer, or fluoresce …
Kinetic bacteriochlorophyll fluorometer.
Kocsis P, Asztalos E, Gingl Z, Maróti P. Kocsis P, et al. Photosynth Res. 2010 Jul;105(1):73-82. doi: 10.1007/s11120-010-9556-6. Epub 2010 May 8. Photosynth Res. 2010. PMID: 20454858
A pump and probe fluorometer with a laser diode as single light source has been constructed for measurement of fast induction and relaxation of the fluorescence yield in intact cells, chromatophores and isolated reaction centers of photosynthetic bacteria. The time resolut …
A pump and probe fluorometer with a laser diode as single light source has been constructed for measurement of fast induction and rel …
Development of an image-based fluorometer with smartphone control for paper analytical devices.
Silva Pereira DO, Matos MM, Fonseca A. Silva Pereira DO, et al. Anal Methods. 2023 Sep 28;15(37):4954-4963. doi: 10.1039/d3ay01020a. Anal Methods. 2023. PMID: 37724418
This work describes the construction and evaluation of a fluorometer for use in paper analytical devices, using a smartphone to operate the instrument and to perform real-time image-based detection. In this approach, a circular PAD containing twenty analytical plates is ro …
This work describes the construction and evaluation of a fluorometer for use in paper analytical devices, using a smartphone to opera …
1,433 results