Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1925 2
1926 1
1928 1
1939 1
1956 1
1970 1
1971 1
1972 1
1973 1
1974 1
1976 1
1977 1
1978 1
1979 2
1980 3
1982 2
1983 5
1984 4
1985 2
1986 1
1987 3
1988 2
1989 3
1990 4
1991 2
1992 6
1993 3
1994 3
1996 2
1997 2
1998 3
1999 4
2002 1
2003 1
2006 1
2012 1
2013 1
2014 1
2017 1
2020 3
2021 4
2022 1
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

82 results

Results by year

Filters applied: . Clear all
Page 1
Electrophoresis.
Sonagra AD, Dholariya SJ. Sonagra AD, et al. 2024 Feb 4. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. 2024 Feb 4. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. PMID: 36251838 Free Books & Documents.
This movement hinders sample movement towards the anode and can reduce separation resolution. This effect is known as electroendosmosis. It can be reduced by using ultrapure agarose gel with low sulfate content. . ...Fixed sulfate groups present in agarose can reduce the r …
This movement hinders sample movement towards the anode and can reduce separation resolution. This effect is known as electroendosmosis
Two-phase agarose gel-electromembrane extraction: Effect of organic solvent as an acceptor phase in electroendosmosis flow phenomenon.
Maghsoudi M, Nojavan S, Alexovič M, Tabani H. Maghsoudi M, et al. J Pharm Biomed Anal. 2021 Feb 20;195:113862. doi: 10.1016/j.jpba.2020.113862. Epub 2020 Dec 23. J Pharm Biomed Anal. 2021. PMID: 33388641
Based on our results, this simple adjustment significantly reduced electroendosmosis (EEO) flow phenomenon which is considered as the main issue in G-EME. ...
Based on our results, this simple adjustment significantly reduced electroendosmosis (EEO) flow phenomenon which is considered as the …
ELECTROENDOSMOSIS THROUGH MAMMALIAN SEROUS MEMBRANES : I. THE HYDROGEN ION REVERSAL POINT WITH BUFFERS CONTAINING POLYVALENT ANIONS.
Mudd S. Mudd S. J Gen Physiol. 1925 Jan 20;7(3):389-413. doi: 10.1085/jgp.7.3.389. J Gen Physiol. 1925. PMID: 19872145 Free PMC article.
Streaming is toward the anode on the acid side of the reversal point. Simple means for studying this electroendosmosis quantitatively are described. The mean values of the reversal points in all cases studied with the present buffers lie between pH = 4.3 and 5.3. ...
Streaming is toward the anode on the acid side of the reversal point. Simple means for studying this electroendosmosis quantitatively …
The effects of electroendosmosis in agarose electrophoresis.
Guo Y, Li X, Fang Y. Guo Y, et al. Electrophoresis. 1998 Jun;19(8-9):1311-3. doi: 10.1002/elps.1150190816. Electrophoresis. 1998. PMID: 9694271
The effects of agarose gel strips without and with 0.03 m(r) electroendosmosis (EEO) on isoelectric focusing (IEF) were studied. It is shown that only agarose without EEO can be used for IEF. ...
The effects of agarose gel strips without and with 0.03 m(r) electroendosmosis (EEO) on isoelectric focusing (IEF) were studied. It i …
A new type of pH- and detergent-stable coating for elimination of electroendosmosis and adsorption in (capillary) electrophoresis.
Hjertén S, Kubo K. Hjertén S, et al. Electrophoresis. 1993 May-Jun;14(5-6):390-5. doi: 10.1002/elps.1150140164. Electrophoresis. 1993. PMID: 8394805
We describe a method to coat fused silica, quartz, or glass electrophoresis tubes with hydrophilic polymers, such as methyl cellulose or dextran, in order to eliminate electroendosmosis and adsorption of solutes onto the tube wall. The coating was not split off upon exposu …
We describe a method to coat fused silica, quartz, or glass electrophoresis tubes with hydrophilic polymers, such as methyl cellulose or dex …
82 results