Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1969 1
1970 3
1971 3
1972 5
1973 6
1974 8
1975 16
1976 9
1977 17
1978 13
1979 13
1980 26
1981 22
1982 14
1983 32
1984 43
1985 44
1986 55
1987 33
1988 42
1989 72
1990 90
1991 81
1992 117
1993 99
1994 105
1995 93
1996 116
1997 101
1998 100
1999 90
2000 116
2001 94
2002 105
2003 105
2004 114
2005 135
2006 130
2007 139
2008 140
2009 149
2010 212
2011 206
2012 192
2013 235
2014 240
2015 234
2016 293
2017 307
2018 307
2019 231
2020 225
2021 159
2022 135
2023 109
2024 37

Text availability

Article attribute

Article type

Publication date

Search Results

5,207 results

Results by year

Filters applied: . Clear all
Page 1
A wearable cardiac ultrasound imager.
Hu H, Huang H, Li M, Gao X, Yin L, Qi R, Wu RS, Chen X, Ma Y, Shi K, Li C, Maus TM, Huang B, Lu C, Lin M, Zhou S, Lou Z, Gu Y, Chen Y, Lei Y, Wang X, Wang R, Yue W, Yang X, Bian Y, Mu J, Park G, Xiang S, Cai S, Corey PW, Wang J, Xu S. Hu H, et al. Nature. 2023 Jan;613(7945):667-675. doi: 10.1038/s41586-022-05498-z. Epub 2023 Jan 25. Nature. 2023. PMID: 36697864 Free PMC article.
However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness(5-11), and existing wearable cardiac devices can only capture signals on the skin(12-16). Here we report a wearable ultrasonic devic …
However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness …
Acute right ventricular myocardial infarction.
Albulushi A, Giannopoulos A, Kafkas N, Dragasis S, Pavlides G, Chatzizisis YS. Albulushi A, et al. Expert Rev Cardiovasc Ther. 2018 Jul;16(7):455-464. doi: 10.1080/14779072.2018.1489234. Epub 2018 Jun 27. Expert Rev Cardiovasc Ther. 2018. PMID: 29902098 Review.
Early revascularization, percutaneous or pharmacological, represents key step in the management of RMVI. Maintenance of reasonable heart rate and atrioventricular synchrony is essential to sustain adequate cardiac output in these patients. When conventional treatment is no …
Early revascularization, percutaneous or pharmacological, represents key step in the management of RMVI. Maintenance of reasonable heart
Left ventricular assist devices and other devices for end-stage heart failure: utility of echocardiography.
Kirkpatrick JN, Wiegers SE, Lang RM. Kirkpatrick JN, et al. Curr Cardiol Rep. 2010 May;12(3):257-64. doi: 10.1007/s11886-010-0102-0. Curr Cardiol Rep. 2010. PMID: 20424970 Review.
The burgeoning ranks of patients with heart failure, the limited number of organs available for heart transplant, and technological improvements have made ventricular assist devices (VADs) important therapeutic options for patients with acute and chronic card …
The burgeoning ranks of patients with heart failure, the limited number of organs available for heart transplant, and technolo …
Stress echocardiography for evaluation of hemodynamics: valvular heart disease, prosthetic valve function, and pulmonary hypertension.
Bach DS. Bach DS. Prog Cardiovasc Dis. 1997 May-Jun;39(6):543-54. doi: 10.1016/s0033-0620(97)80013-8. Prog Cardiovasc Dis. 1997. PMID: 9166365 Review.
A broad variety of diseases can affect dynamic cardiac function and contribute to exertional symptoms. Although hemodynamic data at rest may be sufficient to guide therapy in some patients with cardiovascular disease, medical and surgical decisions may be impacted b …
A broad variety of diseases can affect dynamic cardiac function and contribute to exertional symptoms. Although hemodynamic data at r …
Mechanical circulatory support devices: methods to optimize hemodynamics during use.
Chung BB, Sayer G, Uriel N. Chung BB, et al. Expert Rev Med Devices. 2017 May;14(5):343-353. doi: 10.1080/17434440.2017.1324292. Expert Rev Med Devices. 2017. PMID: 28448170 Review.
As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as well as the strategies for hemodynamic optimization. Areas covered: This review provides an overview of hemodynamics in the normal huma …
As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as well as t …
The contemporary role of echocardiography in the assessment and management of aortic stenosis.
Kitai T, Tsutsui RS. Kitai T, et al. J Med Ultrason (2001). 2020 Jan;47(1):71-80. doi: 10.1007/s10396-019-00991-x. Epub 2019 Dec 2. J Med Ultrason (2001). 2020. PMID: 31792637 Review.
Aortic stenosis (AS) represents a major healthcare issue because of its ever-increasing prevalence, poor prognosis, and complex pathophysiology. Echocardiography plays a central role in providing a comprehensive morphological and hemodynamic evaluation of AS. ...Thi …
Aortic stenosis (AS) represents a major healthcare issue because of its ever-increasing prevalence, poor prognosis, and complex pathophysiol …
Pacing Optimized by Left Ventricular dP/dtmax.
Elliott MK, Mehta VS, Rinaldi CA. Elliott MK, et al. Card Electrophysiol Clin. 2022 Jun;14(2):223-232. doi: 10.1016/j.ccep.2021.12.002. Epub 2022 May 25. Card Electrophysiol Clin. 2022. PMID: 35715080 Review.
Left ventricular (LV) dP/dt(max) provides a sensitive measure of the acute hemodynamic response to cardiac resynchronization therapy (CRT) and can predict reverse remodeling on echocardiography. ...
Left ventricular (LV) dP/dt(max) provides a sensitive measure of the acute hemodynamic response to cardiac resynchronization therapy …
Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve.
Bach DS, Sakwa MP, Goldbach M, Petracek MR, Emery RW, Mohr FW. Bach DS, et al. Ann Thorac Surg. 2002 Dec;74(6):2003-9; discussion 2009. doi: 10.1016/s0003-4975(02)04034-1. Ann Thorac Surg. 2002. PMID: 12643387
BACKGROUND: The St. Jude Medical Regent valve is the next-generation bileaflet aortic prosthesis, modified from the currently marketed St. ...Left ventricular mass index decreased significantly between early postoperative (165.9 +/- 57.1 g/m2) and 6-month follow-up (137.9 …
BACKGROUND: The St. Jude Medical Regent valve is the next-generation bileaflet aortic prosthesis, modified from the currently markete …
Assessment of hemodynamics properties of a new-type artificial heart valve prosthesis using catheterization and echocardiography.
Zeng YJ, Xu SW, Wang Q, Chang Y, Dong AQ, Chen RK, Yu XJ. Zeng YJ, et al. Am J Hematol. 2006 Aug;81(8):563-7. doi: 10.1002/ajh.20686. Am J Hematol. 2006. PMID: 16823819 Free article.
OBJECTIVE: The objectives of this study were to assess the hemodynamic properties of the newly developed artificial heart valve prosthesis experimentally in laboratory simulation, in an animal model, and clinically in a human model and to compare the results measure …
OBJECTIVE: The objectives of this study were to assess the hemodynamic properties of the newly developed artificial heart valv …
Assessment of Complex Multi-Valve Disease and Prosthetic Valves.
Venneri L, Khattar RS, Senior R. Venneri L, et al. Heart Lung Circ. 2019 Sep;28(9):1436-1446. doi: 10.1016/j.hlc.2019.04.024. Epub 2019 Jun 21. Heart Lung Circ. 2019. PMID: 31266726 Review.
Multivalvular heart disease (MVD) is a highly prevalent condition causing significant morbidity and mortality. The complex haemodynamic interactions between coexisting valve lesions makes the diagnosis and treatment challenging. ...
Multivalvular heart disease (MVD) is a highly prevalent condition causing significant morbidity and mortality. The complex haemody
5,207 results