Display Settings:

Format

Send to:

Choose Destination
We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
    Environ Sci Technol. 2012 Mar 6;46(5):2993-3000. doi: 10.1021/es203388g. Epub 2012 Feb 27.

    Real-time assessment of black carbon pollution in Indian households due to traditional and improved biomass cookstoves.

    Source

    The Energy and Resources Institute, New Delhi, India.

    Erratum in

    • Environ Sci Technol. 2012 Sep 4;46(17):9811.

    Abstract

    Use of improved (biomass) cookstoves (ICs) has been widely proposed as a Black Carbon (BC) mitigation measure with significant climate and health benefits. ICs encompass a range of technologies, including natural draft (ND) stoves, which feature structural modifications to enhance air flow, and forced draft (FD) stoves, which additionally employ an external fan to force air into the combustion chamber. We present here, under Project Surya, the first real-time in situ Black Carbon (BC) concentration measurements from five commercial ICs and a traditional (mud) cookstove for comparison. These experiments reveal four significant findings about the tested stoves. First, FD stoves emerge as the superior IC technology, reducing plume zone BC concentration by a factor of 4 (compared to 1.5 for ND). Indoor cooking-time BC concentrations, which varied from 50 to 1000 μg m(-3) for the traditional mud cookstove, were reduced to 5-100 μg m(-3) by the top-performing FD stove. Second, BC reductions from IC models in the same technology category vary significantly: for example, some ND models occasionally emit more BC than a traditional cookstove. Within the ND class, only microgasification stoves were effective in reducing BC. Third, BC concentration varies significantly for repeated cooking cycles with same stove (standard deviation up to 50% of mean concentration) even in a standardized setup, highlighting inherent uncertainties in cookstove performance. Fourth, use of mixed fuel (reflective of local practices) increases plume zone BC concentration (compared to hardwood) by a factor of 2 to 3 across ICs.

    PMID:
    22369148
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for American Chemical Society

      Save items

      Search details

      See more...

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk