Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1972 1
1983 1
1984 1
1986 1
1987 1
1989 1
1992 1
1993 1
1997 1
2001 2
2002 1
2005 1
2008 1
2009 1
2012 1
2016 1
2019 2
2020 4
2021 4
2022 1
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

27 results

Results by year

Filters applied: . Clear all
Page 1
Double-plate fixation together with bridging bone grafting in nonunion of femoral supracondylar, subtrochanteric, and shaft fractures is an effective technique.
Mardani-Kivi M, Karimi Mobarakeh M, Keyhani S, Azari Z. Mardani-Kivi M, et al. Musculoskelet Surg. 2020 Aug;104(2):215-226. doi: 10.1007/s12306-019-00615-0. Epub 2019 Jun 26. Musculoskelet Surg. 2020. PMID: 31243698
PURPOSE: The aims of the present study were to evaluate and report the therapeutic outcomes of double-plate fixation in combination with autogenous bridging bone grafting in treatment of nonunion fractures of femur. METHODS: In this retrospective case series …
PURPOSE: The aims of the present study were to evaluate and report the therapeutic outcomes of double-plate fixation in combination with aut …
Simple approach to the management of aseptic non-union of the shaft of long bones.
Devnani AS. Devnani AS. Singapore Med J. 2001 Jan;42(1):20-5. Singapore Med J. 2001. PMID: 11361233 Review.
This study was done to see the outcome of plate-fixation for the treatment of non-union of the shaft of long bones. METHOD: The non-union was treated by freshening the fracture ends, opening the medullary canal, re-aligning and stabilizing the fracture with a …
This study was done to see the outcome of plate-fixation for the treatment of non-union of the shaft of long bones. METHOD: The non-u …
Plate augmentation leaving the nail in situ and bone grafting for non-union of femoral shaft fractures.
Choi YS, Kim KS. Choi YS, et al. Int Orthop. 2005 Oct;29(5):287-90. doi: 10.1007/s00264-005-0668-0. Epub 2005 Aug 31. Int Orthop. 2005. PMID: 16132986 Free PMC article.
We reviewed 15 patients with femoral non-union after interlocking intramedullary nailing treated with plate augmentation and bone grafting with the nail in situ. The mean time from primary nailing to plate augmentation and bone grafting was 10 months. At the time of …
We reviewed 15 patients with femoral non-union after interlocking intramedullary nailing treated with plate augmentation and bone gra …
Revision with Locking Compression Plate by Compression Technique for Diaphyseal Nonunions of the Femur and the Tibia: A Retrospective Study of 54 Cases.
Ding P, Chen Q, Zhang C, Yao C. Ding P, et al. Biomed Res Int. 2021 Jul 14;2021:9905067. doi: 10.1155/2021/9905067. eCollection 2021. Biomed Res Int. 2021. PMID: 34368357 Free PMC article.
Nonunion after diaphyseal fracture of the femur or the tibia is a common but difficult complication for treatment. ...To evaluate the outcomes of compression plating in the treatment of femur and tibia shaft nonunions, we retrospectively reviewed 54 pa …
Nonunion after diaphyseal fracture of the femur or the tibia is a common but difficult complication for treatment. ...To evalu …
Reunion of post nail aseptic non-union of diaphyseal femoral fractures by augmentation plating, decortication and bone grafting - Replacement for exchange nailing.
Mittal KK, Gupta H, Kaushik N. Mittal KK, et al. Injury. 2021 Jun;52(6):1529-1533. doi: 10.1016/j.injury.2020.10.036. Epub 2020 Oct 8. Injury. 2021. PMID: 33059926
Intra-medullary nailing in fresh diaphyseal femoral fractures is gold standard treatment with high success rate, still non-union of these fractures is reported, though the incidence has declined considerably. ...Larger nail increases mechanical stability by better f …
Intra-medullary nailing in fresh diaphyseal femoral fractures is gold standard treatment with high success rate, still non-union of t …
Results of indirect reduction and plating of femoral shaft nonunions after intramedullary nailing.
Bellabarba C, Ricci WM, Bolhofner BR. Bellabarba C, et al. J Orthop Trauma. 2001 May;15(4):254-63. doi: 10.1097/00005131-200105000-00004. J Orthop Trauma. 2001. PMID: 11371790
PATIENTS: A consecutive series of twenty-three patients with nonunion of femoral shaft fractures previously treated with intramedullary nailing. INTERVENTION: Surgical treatment with indirect plating techniques using the AO 95-degree condylar blade plate in nonunion …
PATIENTS: A consecutive series of twenty-three patients with nonunion of femoral shaft fractures previously treated with intra …
Use of an intramedullary fibular strut allograft and dual locking plate in periprosthetic fractures above total knee arthroplasty: new application of a well-known treatment method in trauma.
Suh D, Ji JH, Heu JY, Kim JY, Chi H, Lee SW. Suh D, et al. Eur J Trauma Emerg Surg. 2022 Oct;48(5):4105-4111. doi: 10.1007/s00068-022-01940-z. Epub 2022 Mar 6. Eur J Trauma Emerg Surg. 2022. PMID: 35249116
PURPOSE: Augmenting fracture fixation with intramedullary fibular graft has seen several applications such as in comminuted proximal humerus fractures, and femoral neck and shaft nonunion. The purpose of this study was to report the first case series demonstr …
PURPOSE: Augmenting fracture fixation with intramedullary fibular graft has seen several applications such as in comminuted proximal …
Finite-element modelling of femoral shaft fracture fixation techniques post total hip arthroplasty.
Mihalko WM, Beaudoin AJ, Cardea JA, Krause WR. Mihalko WM, et al. J Biomech. 1992 May;25(5):469-76. doi: 10.1016/0021-9290(92)90087-h. J Biomech. 1992. PMID: 1592852
The presence of a femoral prosthesis superior to a shaft fracture severely complicates fixation and treatment. This study uses two-dimensional, multithickness, plane stress finite-element models of a femur with prosthesis to investigate the stresses developed …
The presence of a femoral prosthesis superior to a shaft fracture severely complicates fixation and treatment. This study uses …
Complex nonunion of fractures of the femoral shaft treated by wave-plate osteosynthesis.
Ring D, Jupiter JB, Sanders RA, Quintero J, Santoro VM, Ganz R, Marti RK. Ring D, et al. J Bone Joint Surg Br. 1997 Mar;79(2):289-94. doi: 10.1302/0301-620x.79b2.6886. J Bone Joint Surg Br. 1997. PMID: 9119859
We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different medical centres. ...Union was achieved in 41 patients at an average of six months, although three had required a second bone graft. T …
We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different …
Optimal configuration of a dual locking plate for femoral allograft or recycled autograft bone fixation: A finite element and biomechanical analysis.
Wisanuyotin T, Sirichativapee W, Paholpak P, Kosuwon W, Kasai Y. Wisanuyotin T, et al. Clin Biomech (Bristol, Avon). 2020 Dec;80:105156. doi: 10.1016/j.clinbiomech.2020.105156. Epub 2020 Aug 24. Clin Biomech (Bristol, Avon). 2020. PMID: 32862075
BACKGROUND: Allografts and recycled bone autograft are commonly used for biological reconstruction. The dual locking plates fixation method has been advocated for increasing allograft stability and preventing fixation failure; however, the biomechanical properties o …
BACKGROUND: Allografts and recycled bone autograft are commonly used for biological reconstruction. The dual locking plates fi …
27 results