Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2003 1
2011 1
2013 1
2014 1
2016 2
2022 4
2023 3
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

12 results

Results by year

Filters applied: . Clear all
The following terms were ignored: %, %, %
The following terms were not found in PubMed: 20FD, 5BAuthor
Page 1
Infections following left ventricular assist device implantation and 1-year health-related quality of life.
Zhou S, Yang G, Hou H, Zhang M, Grady KL, Chenoweth CE, Aaronson KD, Pienta M, Fetters MD, Paul Chandanabhumma P, Stewart JW 2nd, Cabrera L, Malani PN, Pagani FD, Likosky DS; Michigan Congestive Heart Failure Investigators. Zhou S, et al. J Heart Lung Transplant. 2023 Sep;42(9):1307-1315. doi: 10.1016/j.healun.2023.05.006. Epub 2023 May 13. J Heart Lung Transplant. 2023. PMID: 37187319
Each additional infection was associated with a 3.49% greater probability of the primary composite outcome and was associated with worse performance across multiple dimensions of HRQOL as assessed by the EQ-5D for patients who survived to 1 year. CONCLUSIONS: For patients …
Each additional infection was associated with a 3.49% greater probability of the primary composite outcome and was associated with worse per …
Use of a Pulmonary Artery Pressure Sensor to Manage Patients With Left Ventricular Assist Devices.
Thohan V, Abraham J, Burdorf A, Sulemanjee N, Jaski B, Guglin M, Pagani FD, Vidula H, Majure DT, Napier R, Heywood TJ, Cogswell R, Dirckx N, Farrar DJ, Drakos SG; INTELLECT 2-HF Investigators. Thohan V, et al. Circ Heart Fail. 2023 Jun;16(6):e009960. doi: 10.1161/CIRCHEARTFAILURE.122.009960. Epub 2023 Apr 20. Circ Heart Fail. 2023. PMID: 37079511 Free PMC article.
METHODS: In this multicenter prospective study, we followed patients with HeartMate II (n=52) or HeartMate 3 (n=49) LVADs and with CardioMEMS PA Sensors and measured pulmonary artery pressure, 6-minute walk distance, quality of life (EQ-5D-5 L scores), and heart failure ho …
METHODS: In this multicenter prospective study, we followed patients with HeartMate II (n=52) or HeartMate 3 (n=49) LVADs and with CardioMEM …
Skilled Nursing Facility Quality Rating and Surgical Outcomes Following Coronary Artery Bypass Grafting.
Stewart JW 2nd, Hou H, Wang Y, Bonner SN, Hawkins RB, Pagani FD, Ailawadi G, Likosky DS, Thompson MP. Stewart JW 2nd, et al. Semin Thorac Cardiovasc Surg. 2022 Nov 17:S1043-0679(22)00270-2. doi: 10.1053/j.semtcvs.2022.11.007. Online ahead of print. Semin Thorac Cardiovasc Surg. 2022. PMID: 36402230
Compared to above average SNFs, patients discharged to below average SNFs experienced higher risk-adjusted 30-day mortality (2.1% vs 1.6%, P<0.02), readmission (21.6% vs 19.3%, P<0.01) and SNF length of stay (17.3d vs 16.5d, P<0.0001). Within 90-days, below averag …
Compared to above average SNFs, patients discharged to below average SNFs experienced higher risk-adjusted 30-day mortality (2.1% vs 1.6%, P …
Incompleteness of health-related quality of life assessments before left ventricular assist device implant: A novel quality metric.
Yang G, Zhang M, Zhou S, Hou H, Grady KL, Stewart JW 2nd, Chenoweth CE, Aaronson KD, Fetters MD, Chandanabhumma PP, Pienta MJ, Malani PN, Hider AM, Cabrera L, Pagani FD, Likosky DS; Michigan Congestive Heart Failure Investigators. Yang G, et al. J Heart Lung Transplant. 2022 Oct;41(10):1520-1528. doi: 10.1016/j.healun.2022.07.001. Epub 2022 Jul 8. J Heart Lung Transplant. 2022. PMID: 35961829 Free PMC article.
HRQOL incompleteness at high-rate hospitals was more often due to administrative reasons (risk difference, EQ-5D: 10.1%; KCCQ-12: 11.6%) and less likely due to patient reasons (risk difference, EQ-5D: -8.9%; KCCQ-12: -11.4%). A 10% increase in the adjusted pre-impla …
HRQOL incompleteness at high-rate hospitals was more often due to administrative reasons (risk difference, EQ-5D: 10.1%; KCCQ-12: 11. …
Change in Caregiver Health-Related Quality of Life From Before to Early After Surgery: SUSTAIN-IT Study.
Chuzi S, Wilcox JE, Kao A, Spertus JA, Hsich E, Dew MA, Yancy CW, Pham DT, Hartupee J, Petty M, Cotts W, Pamboukian SV, Pagani FD, Lampert B, Johnson M, Murray M, Takeda K, Yuzefpolskaya M, Silvestry S, Kirklin JK, Wu T, Andrei AC, Baldridge A, Grady KL. Chuzi S, et al. Circ Heart Fail. 2023 Aug;16(8):e010038. doi: 10.1161/CIRCHEARTFAILURE.122.010038. Epub 2023 Jun 22. Circ Heart Fail. 2023. PMID: 37345518
METHODS: Caregivers of older patients (60-80 years) from 13 US sites completed the EQ-5D-3 L visual analog scale (0 [worst]-100 [best] imaginable health state) and dimensions before and 3 and 6 months post-surgery. ...RESULTS: Among 227 caregivers (HT MCS=54, HT non-MCS=76 …
METHODS: Caregivers of older patients (60-80 years) from 13 US sites completed the EQ-5D-3 L visual analog scale (0 [worst]-100 [best …
Baseline Quality-of-Life of Caregivers of Patients With Heart Failure Prior to Advanced Therapies: Findings From the Sustaining Quality of Life of the Aged: Transplant or Mechanical Support (SUSTAIN-IT) Study.
Petty MG, Wu T, Andrei AC, Baldridge A, Warzecha A, Kao A, Spertus J, Hsich E, Dew MA, Pham D, Yancy C, Hartupee J, Cotts W, Pamboukian SV, Pagani F, Lampert B, Johnson M, Murray M, Tekeda K, Yuzefpolskaya M, Silvestry S, Kirklin JK, Grady KL. Petty MG, et al. J Card Fail. 2022 Jul;28(7):1137-1148. doi: 10.1016/j.cardfail.2022.03.358. Epub 2022 Apr 22. J Card Fail. 2022. PMID: 35470057 Free PMC article.
METHODS: Caregivers (n = 281) recruited from 13 HT and MCS programs in the United States completed measures of HRQOL (EQ-5D-3L), depressive symptoms (PHQ-8), anxiety (STAI-state), and burden (Oberst Caregiving Burden Scale). ...Caregivers (HT with MCS = 87, HT without MCS …
METHODS: Caregivers (n = 281) recruited from 13 HT and MCS programs in the United States completed measures of HRQOL (EQ-5D-3L), depr …
Health-Related Quality of Life in Older Patients With Advanced Heart Failure: Findings From the SUSTAIN-IT Study.
Grady KL, Andrei AC, Elenbaas C, Warzecha A, Baldridge A, Kao A, Spertus JA, Pham DT, Dew MA, Hsich E, Cotts W, Hartupee J, Pamboukian SV, Pagani FD, Petty M, Lampert B, Johnson M, Murray M, Takeda K, Yuzefpolskaya M, Silvestry S, Kirklin JK, Yancy C. Grady KL, et al. J Am Heart Assoc. 2022 Feb 15;11(4):e024385. doi: 10.1161/JAHA.121.024385. Epub 2022 Feb 12. J Am Heart Assoc. 2022. PMID: 35156421 Free PMC article.
Long-term MCS candidates had worse HRQOL than HT candidates with and without MCS (EQ-5D visual analog scale scores, 4623 versus 6818 versus 5423 [P<0.001] and Kansas City Cardiomyopathy Questionnaire-12 overall summary scores, 3521 versus 6021 versus 4922 [P<0.001], …
Long-term MCS candidates had worse HRQOL than HT candidates with and without MCS (EQ-5D visual analog scale scores, 4623 versus 6818 …
Patients Awaiting Heart Transplantation on HVAD Support for Greater Than 2 Years.
Aaronson KD, Silvestry SC, Maltais S, Mallidi HR, Frazier OH, Boyce SW, Leadley K, Najarian KB, Slaughter MS, Pagani FD. Aaronson KD, et al. ASAIO J. 2016 Jul-Aug;62(4):384-9. doi: 10.1097/MAT.0000000000000380. ASAIO J. 2016. PMID: 27111739
In addition, the long-term cohort displayed significant improvements in Kansas City Cardiomyopathy Questionnaire Overall Summary Score, EuroQOL-5D Overall Health State Score, and 6 minute walk scores from baseline values. ...
In addition, the long-term cohort displayed significant improvements in Kansas City Cardiomyopathy Questionnaire Overall Summary Score, Euro …
Age and gender differences and factors related to change in health-related quality of life from before to 6 months after left ventricular assist device implantation: Findings from Interagency Registry for Mechanically Assisted Circulatory Support.
Grady KL, Sherri Wissman, Naftel DC, Myers S, Gelijins A, Moskowitz A, Pagani FD, Young JB, Spertus JA, Kirklin JK. Grady KL, et al. J Heart Lung Transplant. 2016 Jun;35(6):777-88. doi: 10.1016/j.healun.2016.01.1222. Epub 2016 Feb 8. J Heart Lung Transplant. 2016. PMID: 27068037 Free PMC article.
Of these, 5,640 patients had pre-LVAD HRQOL data, 3,353 patients had 6-month post-LVAD HRQOL data, and 2,748 patients had data at both times. HRQOL was measured using the EQ-5D-3L (Euro-Qol) instrument. Data were collected pre-implant and 3 and 6 months post-operatively. . …
Of these, 5,640 patients had pre-LVAD HRQOL data, 3,353 patients had 6-month post-LVAD HRQOL data, and 2,748 patients had data at both times …
Overall quality of life improves to similar levels after mechanical circulatory support regardless of severity of heart failure before implantation.
Grady KL, Naftel D, Stevenson L, Dew MA, Weidner G, Pagani FD, Kirklin JK, Myers S, Baldwin T, Young J. Grady KL, et al. J Heart Lung Transplant. 2014 Apr;33(4):412-21. doi: 10.1016/j.healun.2013.10.017. Epub 2013 Oct 23. J Heart Lung Transplant. 2014. PMID: 24360203 Free PMC article.
METHODS: Data from 1,559 adults with advanced heart failure who received primary continuous-flow pumps between June 23, 2006, and March 31, 2010, and were enrolled in INTERMACS were analyzed. HRQOL data were collected using the EQ-5D-3L survey before implantation and at 3, …
METHODS: Data from 1,559 adults with advanced heart failure who received primary continuous-flow pumps between June 23, 2006, and March 31, …
12 results