Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2002 1
2003 2
2004 2
2007 1
2008 1
2012 1
2014 2
2017 1
2020 1
2022 5
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

15 results

Results by year

Filters applied: . Clear all
Page 1
High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye.
Chen S, Potsaid B, Li Y, Lin J, Hwang Y, Moult EM, Zhang J, Huang D, Fujimoto JG. Chen S, et al. Sci Rep. 2022 Jan 19;12(1):992. doi: 10.1038/s41598-022-04784-0. Sci Rep. 2022. PMID: 35046423 Free PMC article.
This study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity surface-emitting laser (VCSEL) light sources, signal processing, optics and mechanical designs, enable a …
This study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterio …
A closed-loop, all-electronic pixel-wise adaptive imaging system for high dynamic range videography.
Zhang J, Newman JP, Wang X, Thakur CS, Rattray J, Etienne-Cummings R, Wilson MA. Zhang J, et al. IEEE Trans Circuits Syst I Regul Pap. 2020 Jun;67(6):1803-1814. doi: 10.1109/tcsi.2020.2973396. Epub 2020 Feb 27. IEEE Trans Circuits Syst I Regul Pap. 2020. PMID: 36845010 Free PMC article.
Digital cameras expose and readout all pixels in accordance with a global sample clock. ...To evaluate performance, we used this system to capture scenes with complex lighting and motion conditions that would lead to loss of information for globally-exposed camer
Digital cameras expose and readout all pixels in accordance with a global sample clock. ...To evaluate performance, we used th
[Application of navigation in the fractured spine].
Richter PH, Gebhard F. Richter PH, et al. Oper Orthop Traumatol. 2023 Feb;35(1):29-36. doi: 10.1007/s00064-022-00790-7. Epub 2022 Nov 28. Oper Orthop Traumatol. 2023. PMID: 36441223 Review. German.
Failure of DRB fixation is the major contraindication for navigation in the spine. SURGICAL TECHNIQUE: After acquisition of an intraoperative three-dimensional (3D) scan, a digital relation between the anatomy and the 3D scan is established with the navigation syste …
Failure of DRB fixation is the major contraindication for navigation in the spine. SURGICAL TECHNIQUE: After acquisition of an intrao …
The morphometrical and topographical evaluation of the superior gluteal nerve in the prenatal period.
Kędzia A, Dudek K, Ziajkiewicz M, Wolanczyk M, Seredyn A, Derkowski W, Domagala ZA. Kędzia A, et al. PLoS One. 2022 Aug 26;17(8):e0273397. doi: 10.1371/journal.pone.0273397. eCollection 2022. PLoS One. 2022. PMID: 36018841 Free PMC article.
MATERIAL AND METHODS: The study was carried out on 40 human fetuses (20 females and 20 males) aged from 15 to 29 weeks (total body length v-pl from 130 to 345 mm). Following methods were used: anthropological, preparatory, image acquisition with a digital
MATERIAL AND METHODS: The study was carried out on 40 human fetuses (20 females and 20 males) aged from 15 to 29 weeks (total body length v- …
High dynamic range electron imaging: the new standard.
Evans K, Beanland R. Evans K, et al. Microsc Microanal. 2014 Oct;20(5):1601-4. doi: 10.1017/S1431927614012975. Microsc Microanal. 2014. PMID: 25256651
Hardware solutions such as readable phosphor imaging plates have existed since the 1990s, but in recent years the advent of robust CCD digital cameras capable of capturing high intensities in a transmission electron microscope has made image
Hardware solutions such as readable phosphor imaging plates have existed since the 1990s, but in recent years the advent of robust CC …
Bionic orientation method based on polarization imaging in HDR scenes.
Wu X, Fan C, He X, Zhang L, Hu X, Fan Y, Han G, Zhou W, Shang H. Wu X, et al. Appl Opt. 2022 Mar 10;61(8):2007-2018. doi: 10.1364/AO.448701. Appl Opt. 2022. PMID: 35297893
An increasing number of bio-inspired navigation approaches have been designed based on polarization cameras. However, digital cameras can sense a much narrower field of vision than the vision of insects or human beings. In this study, we propose an adaptive s …
An increasing number of bio-inspired navigation approaches have been designed based on polarization cameras. However, digital
Impact of technology on the utilisation of positron emission tomography in lymphoma: current and future perspectives.
Visvikis D, Ell PJ. Visvikis D, et al. Eur J Nucl Med Mol Imaging. 2003 Jun;30 Suppl 1:S106-16. doi: 10.1007/s00259-003-1168-3. Epub 2003 May 13. Eur J Nucl Med Mol Imaging. 2003. PMID: 12748830 Review.
The challenges ahead are determined by the need for high-quality whole-body imaging associated with increased patient throughput and the need to investigate the role of new labelled ligands. ...The study of new radiolabelled ligands will impose further demands for r …
The challenges ahead are determined by the need for high-quality whole-body imaging associated with increased patient throughp …
Suppressing Shot Noise Using Quadratic Variable Step-Size Quantization for the Initial Acquisition of Camera-Raw Image Data.
Lin J, Qin J, Lu S. Lin J, et al. IEEE Trans Image Process. 2022;31:5242-5256. doi: 10.1109/TIP.2022.3184256. Epub 2022 Aug 8. IEEE Trans Image Process. 2022. PMID: 35737634
Digital images from today's premium digital cameras have a higher dynamic range than what humans can perceive. ...In this paper, we show that the extractable image information contained in high-quality HDR images take
Digital images from today's premium digital cameras have a higher dynamic range than what humans c
Demonstration of the CDMA-mode CAOS smart camera.
Riza NA, Mazhar MA. Riza NA, et al. Opt Express. 2017 Dec 11;25(25):31906-31920. doi: 10.1364/OE.25.031906. Opt Express. 2017. PMID: 29245860 Free article.
Demonstrated is the code division multiple access (CDMA)-mode coded access optical sensor (CAOS) smart camera suited for bright target scenarios. Deploying a silicon CMOS sensor and a silicon point detector within a digital micro-mirror device (DMD)-based spatially …
Demonstrated is the code division multiple access (CDMA)-mode coded access optical sensor (CAOS) smart camera suited for bright targe …
Use of intraoperative dynamic infrared imaging with detection wavelength of 7-14 microm in the surgical obliteration of spinal arteriovenous fistula: case report and technical considerations.
Nakagawa A, Hirano T, Uenohara H, Utsunomiya H, Suzuki S, Takayama K, Shirane R, Tominaga T. Nakagawa A, et al. Minim Invasive Neurosurg. 2004 Jun;47(3):136-9. doi: 10.1055/s-2004-818493. Minim Invasive Neurosurg. 2004. PMID: 15343427
The novel camera system (IRIS IV infrared imaging system) was used for the visual monitoring of blood flow during the obliteration of a spinal perimedullary arteriovenous fistula at Th 7 in 71-year-old male patient. ...However, the occasional use of an air blower wa …
The novel camera system (IRIS IV infrared imaging system) was used for the visual monitoring of blood flow during the oblitera …
15 results