Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1977 1
1978 1
1984 2
1986 1
1987 1
1988 2
1989 3
1991 2
1992 7
1993 7
1994 5
1995 7
1996 5
1997 9
1998 3
1999 2
2000 6
2001 5
2002 5
2003 10
2004 5
2005 3
2006 9
2007 5
2008 5
2009 6
2010 8
2011 5
2012 10
2013 11
2014 7
2015 15
2016 5
2017 9
2018 11
2019 3
2020 6
2021 7
2022 3
2023 8
2024 3

Text availability

Article attribute

Article type

Publication date

Search Results

213 results

Results by year

Filters applied: . Clear all
Page 1
Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.
Acciaroli G, Vettoretti M, Facchinetti A, Sparacino G. Acciaroli G, et al. Biosensors (Basel). 2018 Mar 13;8(1):24. doi: 10.3390/bios8010024. Biosensors (Basel). 2018. PMID: 29534053 Free PMC article. Review.
Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a "raw" current signal via a glucose-oxidase electrochemical reaction. This electrical signal needs to be translated in real-time to …
Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a …
Effect of a Low-Fat Vegan Diet on Body Weight, Insulin Sensitivity, Postprandial Metabolism, and Intramyocellular and Hepatocellular Lipid Levels in Overweight Adults: A Randomized Clinical Trial.
Kahleova H, Petersen KF, Shulman GI, Alwarith J, Rembert E, Tura A, Hill M, Holubkov R, Barnard ND. Kahleova H, et al. JAMA Netw Open. 2020 Nov 2;3(11):e2025454. doi: 10.1001/jamanetworkopen.2020.25454. JAMA Netw Open. 2020. PMID: 33252690 Free PMC article. Clinical Trial.
MAIN OUTCOMES AND MEASURES: At weeks 0 and 16, body weight was assessed using a calibrated scale. Body composition and visceral fat were measured by dual x-ray absorptiometry. ...
MAIN OUTCOMES AND MEASURES: At weeks 0 and 16, body weight was assessed using a calibrated scale. Body composition and visceral fat w …
Hexokinase Method.
Sonagra AD, Motiani A. Sonagra AD, et al. 2023 Mar 23. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. 2023 Mar 23. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024 Jan–. PMID: 36512662 Free Books & Documents.
Many point-of-care testing devices are utilized in emergency and home care settings which use capillary blood to estimate the plasma glucose via a biosensor-based chip. The major drawbacks of such devices are imperfection in dispensing the blood sample to the …
Many point-of-care testing devices are utilized in emergency and home care settings which use capillary blood to estimate the plasma …
Interstitial Glucose and Lactate Levels Are Inversely Correlated With the Body Mass Index: Need for In Vivo Calibration of Glucose Sensor Results With Blood Values in Obese Patients.
Enderle B, Moser I, Kannan C, Schwab KO, Urban G. Enderle B, et al. J Diabetes Sci Technol. 2018 Mar;12(2):341-348. doi: 10.1177/1932296817730377. Epub 2017 Sep 21. J Diabetes Sci Technol. 2018. PMID: 28931321 Free PMC article.

One subject with a BMI of > 34 kg/m(2) showed abdominally as well as the antebrachially significantly reduced tissue glucose values compared to blood glucose values ( P < .001). ...Therefore, an in vivo calibration of glucose levels

One subject with a BMI of > 34 kg/m(2) showed abdominally as well as the antebrachially significantly reduced tissue glucose
Multivariate regression and discreminant calibration models for a novel optical non-invasive blood glucose measurement method named pulse glucometry.
Yamakoshi Y, Ogawa M, Yamakoshi T, Tamura T, Yamakoshi K. Yamakoshi Y, et al. Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:126-9. doi: 10.1109/IEMBS.2009.5335104. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19965121
A novel optical non-invasive in vivo blood glucose concentration (BGL) measurement technique, named "Pulse Glucometry", was combined with a kernel method; support vector machines. The total transmitted radiation intensity (I(lambda)) and the cardiac-related pulsatil …
A novel optical non-invasive in vivo blood glucose concentration (BGL) measurement technique, named "Pulse Glucometry", was co …
Physiological differences between interstitial glucose and blood glucose measured in human subjects.
Kulcu E, Tamada JA, Reach G, Potts RO, Lesho MJ. Kulcu E, et al. Diabetes Care. 2003 Aug;26(8):2405-9. doi: 10.2337/diacare.26.8.2405. Diabetes Care. 2003. PMID: 12882870 Clinical Trial.
OBJECTIVE: This study investigated whether glucose readings from a sensor sampling in interstitial fluid differ substantially from blood glucose (BG) values measured at the same time. ...CONCLUSIONS: Similar results have been reported for other measures of IG …
OBJECTIVE: This study investigated whether glucose readings from a sensor sampling in interstitial fluid differ substantially from …
Glucose concentrations in blood and tissue - a pilot study on variable time lag.
Chlup R, Krejci J, O'Connell M, Sebestova B, Plicka R, Jezova L, Brozova T, Doubravova B, Zalesakova H, Durajkova E, Vojtek J, Bartek J. Chlup R, et al. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2015 Dec;159(4):527-34. doi: 10.5507/bp.2015.007. Epub 2015 Mar 1. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2015. PMID: 25732978 Free article. Clinical Trial.
AIM: The aim of this pilot study was to acquire insight into the parameters of glycaemic control, especially, (1) the time delay (lag phase) between plasma and tissue glucose concentrations in relation to rise and fall in glucose levels and (2) the rate of …
AIM: The aim of this pilot study was to acquire insight into the parameters of glycaemic control, especially, (1) the time delay (lag phase) …
Noninvasive Monitoring of Glucose Using Near-Infrared Reflection Spectroscopy of Skin-Constraints and Effective Novel Strategy in Multivariate Calibration.
Heise HM, Delbeck S, Marbach R. Heise HM, et al. Biosensors (Basel). 2021 Feb 27;11(3):64. doi: 10.3390/bios11030064. Biosensors (Basel). 2021. PMID: 33673679 Free PMC article.
Owing to the tiny absorption bands of the glucose buried among a dominating variable spectral background, multivariate calibration is required to achieve applicability for blood glucose self-monitoring. ...The temporal profile differences between the …
Owing to the tiny absorption bands of the glucose buried among a dominating variable spectral background, multivariate calibration
Physiological reconstruction of blood glucose level using CGMS-signals only.
Koutny T. Koutny T. Sci Rep. 2022 Apr 6;12(1):5796. doi: 10.1038/s41598-022-09884-5. Sci Rep. 2022. PMID: 35388107 Free PMC article.
Alternatively, the patient measures interstitial fluid glucose level with a sensor installed in subcutaneous tissue. Then, a model of glucose dynamics calculates blood glucose level from the sensor-measured, i.e., interstitial fluid glucose
Alternatively, the patient measures interstitial fluid glucose level with a sensor installed in subcutaneous tissue. Then, a m …
Hypoglycemia warning signal and glucose sensors: requirements and concepts.
Heise T, Koschinsky T, Heinemann L, Lodwig V; Glucose Monitoring Study Group. Heise T, et al. Diabetes Technol Ther. 2003;5(4):563-71. doi: 10.1089/152091503322250587. Diabetes Technol Ther. 2003. PMID: 14511411 Review.
Using the approach of a "Finite State Machine," such a more advanced warning system can completely be described as a finite collection of four states and possible transitions in-between. Most of the currently available glucose monitoring systems measure glucose in t …
Using the approach of a "Finite State Machine," such a more advanced warning system can completely be described as a finite collection of fo …