Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
World J Gastroenterol. 2011 Mar 14;17(10):1373-8. doi: 10.3748/wjg.v17.i10.1373.

Autoantibodies against MMP-7 as a novel diagnostic biomarker in esophageal squamous cell carcinoma.

Author information

  • 1Department of Cell Biology, Hebei University, Baoding 071400, Hebei Province, China.

Abstract

AIM:

To evaluate the diagnostic values of serum autoantibodies against matrix metalloproteinase-7 (MMP-7) in patients with esophageal squamous cell carcinoma (ESCC).

METHODS:

The MMP-7 cDNA was cloned from ESCC tissues, and MMP-7 was expressed and purified from a prokaryotic system. MMP-7 autoantibodies were then measured in sera from 50 patients with primary ESCC and 58 risk-matched controls, using a reverse capture enzyme-linked immunosorbent assay (ELISA) in which autoantibodies to MMP-7 bound to the purified MMP-7 proteins. In addition, MMP-7 autoantibody levels in sera from 38 gastric cancer patients and from control serum samples were also tested.

RESULTS:

The optimum conditions for recombinant MMP-7 protein expression were determined as 0.04 mmol/L Isopropyl-β-D-Thiogalactopyranoside (IPTG) induction at 37°C for four hours. The levels of serum autoantibodies against MMP-7 were significantly higher in patients with ESCC than in the matched-control samples (OD450 = 1.69 ± 0.08 vs OD450 = 1.55 ± 0.10, P < 0.001). The area under the receiver operating characteristic (ROC) curve was 0.87. The sensitivity and specificity for detection of ESCC were 78.0% and 81.0%, respectively, when the OD450 value was greater than 1.65. Although the levels of autoantibodies against MMP-7 were also significantly higher in patients with gastric cancer compared to control samples (OD450 = 1.62 ± 0.06 vs OD450 = 1.55 ± 0.10, P < 0.001), the diagnostic accuracy was less significant than in ESCC patients. The area of ROC curve was 0.75, whereas the sensitivity and specificity were 60.5% and 71.7%, respectively, when the cut-off value of OD450 was set at 1.60.

CONCLUSION:

Serum autoantibody levels of MMP-7 may be a good diagnostic biomarker for esophageal squamous cell carcinoma.

KEYWORDS:

Biomarker; Esophageal squamous cell carcinoma; Gastric cancer; Matrix metalloproteinase-7; Serum autoantibody

PMID:
21455340
[PubMed - indexed for MEDLINE]
PMCID:
PMC3068276
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Baishideng Publishing Group Inc. Icon for PubMed Central
    Loading ...
    Write to the Help Desk