Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1927 5
1928 1
1929 1
1933 2
1935 1
1936 2
1937 2
1938 5
1939 5
1940 10
1941 9
1942 7
1943 6
1944 1
1945 20
1946 37
1947 75
1948 80
1949 77
1950 163
1951 154
1952 184
1953 223
1954 255
1955 230
1956 258
1957 245
1958 201
1959 218
1960 233
1961 236
1962 305
1963 566
1964 979
1965 660
1966 669
1967 962
1968 1112
1969 1252
1970 1173
1971 1381
1972 1408
1973 1679
1974 1609
1975 1694
1976 1617
1977 1592
1978 1448
1979 1459
1980 1521
1981 1584
1982 1580
1983 1803
1984 1876
1985 1987
1986 2064
1987 2052
1988 2222
1989 2468
1990 2638
1991 2810
1992 2892
1993 2896
1994 2845
1995 2946
1996 3205
1997 3287
1998 3370
1999 3459
2000 3472
2001 3547
2002 3546
2003 3784
2004 3905
2005 4003
2006 3902
2007 4063
2008 4253
2009 4321
2010 4642
2011 4678
2012 4993
2013 5117
2014 5255
2015 5223
2016 5182
2017 5100
2018 4965
2019 4872
2020 5613
2021 5746
2022 4978
2023 4301
2024 1377

Text availability

Article attribute

Article type

Publication date

Search Results

173,120 results

Results by year

Filters applied: . Clear all
Page 1
The patient with a cardiac pacemaker or implanted defibrillator and management during anaesthesia.
Rozner MA. Rozner MA. Curr Opin Anaesthesiol. 2007 Jun;20(3):261-8. doi: 10.1097/ACO.0b013e32814f1c4a. Curr Opin Anaesthesiol. 2007. PMID: 17479032 Review.
PURPOSE OF REVIEW: Worldwide, nearly 3 million patients have cardiac pacemakers and more than 300,000 have implantable cardioverter-defibrillators. ...Additionally, evidence suggests that postoperative re-interrogation of any cardiac generator is warranted if …
PURPOSE OF REVIEW: Worldwide, nearly 3 million patients have cardiac pacemakers and more than 300,000 have implantable cardiov …
Leadless Cardiac Pacemakers: The Next Evolution in Pacemaker Technology.
McCauley BD, Chu AF. McCauley BD, et al. R I Med J (2013). 2017 Nov 1;100(11):31-34. R I Med J (2013). 2017. PMID: 29088572 Review.
Annually, over 225,000 new pacemakers are implanted in the United States for bradyarrhythmias and heart block. ...Improvements in battery life, device miniaturization, catheter-based delivery tools, and advanced programming have made leadless cardiac pacem
Annually, over 225,000 new pacemakers are implanted in the United States for bradyarrhythmias and heart block. ...Improvements …
Reduced-dose warfarin or interrupted warfarin with heparin bridging for pacemaker or defibrillator implantation: a randomized trial.
Schulman S, Healey JS, Douketis JD, Delaney J, Morillo CA. Schulman S, et al. Thromb Res. 2014 Oct;134(4):814-8. doi: 10.1016/j.thromres.2014.07.028. Epub 2014 Aug 1. Thromb Res. 2014. PMID: 25127655 Clinical Trial.
METHODS: In a randomized controlled trial we compared two regimens for management of anticoagulation with warfarin in patients with implantation of a pacemaker or defibrillator. ...One pocket hematoma in each group was severe. There were no major hemorrhag
METHODS: In a randomized controlled trial we compared two regimens for management of anticoagulation with warfarin in patients with i …
Rate-modulated pacing.
Furman S. Furman S. Circulation. 1990 Oct;82(4):1081-94. doi: 10.1161/01.cir.82.4.1081. Circulation. 1990. PMID: 2205412 Review.
Previously, the rate of cardiac stimulation had been determined either at pacemaker manufacture, by programming a single rate, or by sensing the atrium. ...Some sensors respond to muscle work but not to intellectual effort or emotion. Pacemaker-based sensors …
Previously, the rate of cardiac stimulation had been determined either at pacemaker manufacture, by programming a single rate, …
Pocket Hematoma: A Call for Definition.
DE Sensi F, Miracapillo G, Cresti A, Severi S, Airaksinen KE. DE Sensi F, et al. Pacing Clin Electrophysiol. 2015 Aug;38(8):909-13. doi: 10.1111/pace.12665. Epub 2015 Jun 11. Pacing Clin Electrophysiol. 2015. PMID: 25974662 Review.
Pocket hematoma is a common complication of cardiac implantable electronic device procedures and a potential risk factor for device infections, especially in patients on oral anticoagulation or antiplatelet treatment. There is a wide variability in the incidence of …
Pocket hematoma is a common complication of cardiac implantable electronic device procedures and a potential risk factor for d …
Preparation for pacemaker or implantable cardiac defibrillator implants in patients with high risk of thrombo-embolic events: oral anticoagulation or bridging with intravenous heparin? A prospective randomized trial.
Tolosana JM, Berne P, Mont L, Heras M, Berruezo A, Monteagudo J, Tamborero D, Benito B, Brugada J. Tolosana JM, et al. Eur Heart J. 2009 Aug;30(15):1880-4. doi: 10.1093/eurheartj/ehp194. Epub 2009 May 31. Eur Heart J. 2009. PMID: 19487235 Free PMC article. Clinical Trial.
AIMS: Current guidelines recommend stopping oral anticoagulation (OAC) and starting heparin infusion before implanting/replacing a pacemaker/implantable cardioverter-defibrillator (ICD) in patients with high risk for thrombo-embolic events. ...A total of 4/51 patien …
AIMS: Current guidelines recommend stopping oral anticoagulation (OAC) and starting heparin infusion before implanting/replacing a …
Perioperative anticoagulation in patients having implantation of a cardiac pacemaker or defibrillator: a systematic review and practical management guide.
Jamula E, Douketis JD, Schulman S. Jamula E, et al. J Thromb Haemost. 2008 Oct;6(10):1615-21. doi: 10.1111/j.1538-7836.2008.03080.x. Epub 2008 Jul 12. J Thromb Haemost. 2008. PMID: 18638011 Free article. Review.
We included studies involving patients who were having pacemaker or ICD implantation whenever a portion of these patients were receiving a coumarin and also assessed pocket hematoma or thromboembolism. RESULTS: We identified eight studies that assessed two strategie …
We included studies involving patients who were having pacemaker or ICD implantation whenever a portion of these patients were receiv …
Device-device interaction between cardiac implantable electronic devices and continuous-flow left ventricular assist devices.
Tanawuttiwat T, Das MK, Miller JM, Guglin ME. Tanawuttiwat T, et al. Heart Rhythm. 2023 Jun;20(6):918-926. doi: 10.1016/j.hrthm.2023.02.020. Epub 2023 Feb 28. Heart Rhythm. 2023. PMID: 36863637 Review.
The current design of an innovative left ventricular assist device (LVAD) makes use of magnetic levitation technology, which enables the rotors of the device to be completely suspended by magnetic force, reducing friction and blood or plasma damage. However, this electroma …
The current design of an innovative left ventricular assist device (LVAD) makes use of magnetic levitation technology, which enables the rot …
Comparison of in-hospital outcomes and complications of leadless pacemaker and traditional transvenous pacemaker implantation.
Alhuarrat MAD, Kharawala A, Renjithlal S, Magdi Eid M, Varrias D, Mohammed M, Grushko M, Di Biase L. Alhuarrat MAD, et al. Europace. 2023 Aug 2;25(9):euad269. doi: 10.1093/europace/euad269. Europace. 2023. PMID: 37712644 Free PMC article.
AIMS: Since their introduction in 1958, traditional cardiac pacemakers have undergone considerable upgrades over the years, but they continue to have a complication rate of 3.8%-12.4%. There are no randomized controlled trials comparing outcomes of leadless pacem
AIMS: Since their introduction in 1958, traditional cardiac pacemakers have undergone considerable upgrades over the years, bu …
Sub-pocket small-hole drainage for pocket hematoma after cardiac device implantation.
Wei Y, Cai L, Wu X, Zhou G, Lu X, Peng S, Ding Y, Xu J, Chen S, Ouyang P, Liu S. Wei Y, et al. Herz. 2022 Feb;47(1):63-66. doi: 10.1007/s00059-021-05037-y. Epub 2021 Apr 22. Herz. 2022. PMID: 33890136 Review. English.
AIMS: Pocket hematoma is a common complication associated with cardiac device implantation, but there are limited strategies to deal with this problem. ...CONCLUSION: Sub-pocket small-hole drainage is an alternative approach for dealing with severe pocket hematom
AIMS: Pocket hematoma is a common complication associated with cardiac device implantation, but there are limited strategies t …
173,120 results
You have reached the last available page of results. Please see the User Guide for more information.