Format

Send to

Choose Destination

Links from PubMed

See comment in PubMed Commons below
Appl Opt. 1994 Oct 20;33(30):7045-58. doi: 10.1364/AO.33.007045.

Differential absorption lidar system for routine monitoring of tropospheric ozone.

Abstract

A differential absorption lidar system for routine profiling of tropospheric ozone for daytime and nighttime operation is described. The system uses stimulated Raman scattering in hydrogen and deuterium of 266-nm radiation from a quadrupled Nd:YAG laser. Ozone profiles from altitudes of 600 m to approximately 5 km have been obtained with analog detection. Implementing corrections for differential Rayleigh scattering, differential absorption from oxygen, sulphur dioxide, and nitrogen dioxide, and differential aerosol extinction and backscatter can reduce the total system inaccuracy to 5-15% for a clear day and 20-30% for a hazy day, except at the top of the mixed layer. Photon counting must be installed to increase the measurement range from 5 to 15 km. An example of an application of routine measurements of tropospheric ozone profiles is given.

PMID:
20941256
[PubMed]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Loading ...
    Write to the Help Desk