Format
Items per page
Sort by

Send to:

Choose Destination

Results: 10

Cited In for PubMed (Select 20389713)

1.

Circulating Tumor Cell Detection and Capture by Photoacoustic Flow Cytometry in Vivo and ex Vivo.

Galanzha EI, Zharov VP.

Cancers (Basel). 2013 Dec 10;5(4):1691-738. doi: 10.3390/cancers5041691.

2.

Chemically Specific Imaging Through Stimulated Raman Photoexcitation and Ultrasound Detection: Minireview.

Yakovlev VV, Petrov GI, Zhang HF, Noojin GD, Thomas PA, Denton ML, Rockwell BA, Thomas RJ.

Aust J Chem. 2012 Jan 1;65(3):260-265.

3.

Advanced contrast nanoagents for photoacoustic molecular imaging, cytometry, blood test and photothermal theranostics.

de la Zerda A, Kim JW, Galanzha EI, Gambhir SS, Zharov VP.

Contrast Media Mol Imaging. 2011 Sep-Oct;6(5):346-69. doi: 10.1002/cmmi.455. Review.

4.

In vivo photoacoustic and photothermal cytometry for monitoring multiple blood rheology parameters.

Galanzha EI, Zharov VP.

Cytometry A. 2011 Oct;79(10):746-57. doi: 10.1002/cyto.a.21133. Epub 2011 Aug 30. Review.

5.

In vivo flow cytometry: a horizon of opportunities.

Tuchin VV, Tárnok A, Zharov VP.

Cytometry A. 2011 Oct;79(10):737-45. doi: 10.1002/cyto.a.21143. Epub 2011 Sep 13. Review.

6.

In vivo plant flow cytometry: a first proof-of-concept.

Nedosekin DA, Khodakovskaya MV, Biris AS, Wang D, Xu Y, Villagarcia H, Galanzha EI, Zharov VP.

Cytometry A. 2011 Oct;79(10):855-65. doi: 10.1002/cyto.a.21128. Epub 2011 Sep 8.

7.

In vivo multispectral photoacoustic and photothermal flow cytometry with multicolor dyes: a potential for real-time assessment of circulation, dye-cell interaction, and blood volume.

Proskurnin MA, Zhidkova TV, Volkov DS, Sarimollaoglu M, Galanzha EI, Mock D, Nedosekin DA, Zharov VP.

Cytometry A. 2011 Oct;79(10):834-47. doi: 10.1002/cyto.a.21127. Epub 2011 Sep 8.

8.

Label-free bond-selective imaging by listening to vibrationally excited molecules.

Wang HW, Chai N, Wang P, Hu S, Dou W, Umulis D, Wang LV, Sturek M, Lucht R, Cheng JX.

Phys Rev Lett. 2011 Jun 10;106(23):238106. Epub 2011 Jun 10. Erratum in: Phys Rev Lett. 2011 Jun 24;106(25):259901.

9.

Monitoring stimulated Raman scattering with photoacoustic detection.

Yakovlev VV, Noojin GD, Denton ML, Rockwell BA, Thomas RJ.

Opt Lett. 2011 Apr 1;36(7):1233-5. doi: 10.1364/OL.36.001233.

10.

Ultrasensitive label-free photothermal imaging, spectral identification, and quantification of cytochrome c in mitochondria, live cells, and solutions.

Brusnichkin AV, Nedosekin DA, Galanzha EI, Vladimirov YA, Shevtsova EF, Proskurnin MA, Zharov VP.

J Biophotonics. 2010 Dec;3(12):791-806. doi: 10.1002/jbio.201000012.

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk