Similar articles for PubMed (Select 25137720)

1.

Motion artifacts in capacitive ECG measurements: reducing the combined effect of DC voltages and capacitance changes using an injection signal.

Serteyn A, Vullings R, Meftah M, Bergmans JW.

IEEE Trans Biomed Eng. 2015 Jan;62(1):264-73. doi: 10.1109/TBME.2014.2348178. Epub 2014 Aug 15.

PMID:
25137720
2.

Using an injection signal to reduce motion artifacts in capacitive ECG measurements.

Serteyn A, Vullings R, Meftah M, Bergmans J.

Conf Proc IEEE Eng Med Biol Soc. 2013;2013:4795-8. doi: 10.1109/EMBC.2013.6610620.

PMID:
24110807
3.

Wavelet approach to artifact noise removal from Capacitive coupled Electrocardiograph.

Lee SM, Kim KK, Park KS.

Conf Proc IEEE Eng Med Biol Soc. 2008;2008:2944-7. doi: 10.1109/IEMBS.2008.4649820.

PMID:
19163323
4.

ECG reconstruction based on the injection of a multi-frequency signal in capacitive measurement systems.

Serteyn A, Vullings R, Meftah M, Bergmans JW.

Conf Proc IEEE Eng Med Biol Soc. 2014 Aug;2014:1864-7. doi: 10.1109/EMBC.2014.6943973.

PMID:
25570341
5.

Noncontact ECG recording system with real time capacitance measurement for motion artifact reduction.

Torfs T, Chen YH, Kim H, Yazicioglu RF.

IEEE Trans Biomed Circuits Syst. 2014 Oct;8(5):617-25. doi: 10.1109/TBCAS.2014.2359053. Epub 2014 Oct 13.

PMID:
25314708
6.

Unobtrusive ECG monitoring in the NICU using a capacitive sensing array.

Atallah L, Serteyn A, Meftah M, Schellekens M, Vullings R, Bergmans JW, Osagiator A, Oetomo SB.

Physiol Meas. 2014 May;35(5):895-913. doi: 10.1088/0967-3334/35/5/895. Epub 2014 Apr 17.

PMID:
24743027
7.

A capacitive electrode with fast recovery feature.

Spinelli E, Haberman M, García P, Guerrero F.

Physiol Meas. 2012 Aug;33(8):1277-88. doi: 10.1088/0967-3334/33/8/1277. Epub 2012 Jul 20.

PMID:
22813845
8.

Triboelectricity in capacitive biopotential measurements.

Wartzek T, Lammersen T, Eilebrecht B, Walter M, Leonhardt S.

IEEE Trans Biomed Eng. 2011 May;58(5):1268-77. doi: 10.1109/TBME.2010.2100393. Epub 2010 Dec 20.

PMID:
21177156
9.

Recording human electrocorticographic (ECoG) signals for neuroscientific research and real-time functional cortical mapping.

Hill NJ, Gupta D, Brunner P, Gunduz A, Adamo MA, Ritaccio A, Schalk G.

J Vis Exp. 2012 Jun 26;(64). pii: 3993. doi: 10.3791/3993.

10.

A biosignal instrumentation system using capacitive coupling for power and signal isolation.

Piipponen KV, Sepponen R, Eskelinen P.

IEEE Trans Biomed Eng. 2007 Oct;54(10):1822-8.

PMID:
17926680
11.

An adaptive algorithm for real-time electrode calibration.

Kidmose P.

Conf Proc IEEE Eng Med Biol Soc. 2011;2011:63-6. doi: 10.1109/IEMBS.2011.6089897.

PMID:
22254251
12.

Effect of pressure and padding on motion artifact of textile electrodes.

Cömert A, Honkala M, Hyttinen J.

Biomed Eng Online. 2013 Apr 8;12:26. doi: 10.1186/1475-925X-12-26.

13.

Novel dry electrodes for ECG monitoring.

Gruetzmann A, Hansen S, Müller J.

Physiol Meas. 2007 Nov;28(11):1375-90. Epub 2007 Oct 12.

PMID:
17978422
14.

Capacitive driven-right-leg grounding in Indirect-contact ECG measurement.

Lim YG, Chung GS, Park KS.

Conf Proc IEEE Eng Med Biol Soc. 2010;2010:1250-3. doi: 10.1109/IEMBS.2010.5626424.

PMID:
21095911
15.

Motion artifact reduction in blood pressure signals using adaptive digital filter with a capacitive sensor.

Choi HS, Park HD, Lee KJ.

Conf Proc IEEE Eng Med Biol Soc. 2007;2007:3285-7.

PMID:
18002697
16.

Cole function and conductance-based parasitic capacitance compensation for cerebral electrical bioimpedance measurements.

Atefi SR, Buendia R, Lindecrantz K, Seoane F.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:3368-71. doi: 10.1109/EMBC.2012.6346687.

PMID:
23366648
17.

Impedance measurement system for determination of capacitive electrode coupling.

Eilebrecht B, Willkomm J, Pohl A, Wartzek T, Leonhardt S.

IEEE Trans Biomed Circuits Syst. 2013 Oct;7(5):682-9. doi: 10.1109/TBCAS.2013.2237905.

PMID:
24232629
18.

A differential capacitive electrical field sensor array for contactless measurement of respiratory rate.

Wartzek T, Weyer S, Leonhardt S.

Physiol Meas. 2011 Oct;32(10):1575-90. doi: 10.1088/0967-3334/32/10/006. Epub 2011 Aug 26.

PMID:
21873763
19.

The reliability and accuracy of a noncontact electrocardiograph system for screening purposes.

Czaplik M, Eilebrecht B, Walocha R, Walter M, Schauerte P, Leonhardt S, Rossaint R.

Anesth Analg. 2012 Feb;114(2):322-7. doi: 10.1213/ANE.0b013e31823f4182. Epub 2011 Nov 21.

PMID:
22104072
20.

Capacitive ECG system with direct access to standard leads and body surface potential mapping.

Oehler M, Schilling M, Esperer HD.

Biomed Tech (Berl). 2009 Dec;54(6):329-35. doi: 10.1515/BMT.2009.042.

PMID:
19938890