In vivo accuracy of two electronic foramen locators based on different operation systems.

Vasconcelos BC, Araújo RB, Silva FC, Luna-Cruz SM, Duarte MA, Fernandes CA.

Braz Dent J. 2014 Jan-Feb;25(1):12-6.

2.

In vivo accuracy of three electronic root canal length measurement devices: Dentaport ZX, Raypex 5 and ProPex II.

Somma F, Castagnola R, Lajolo C, Paternò Holtzman L, Marigo L.

Int Endod J. 2012 Jun;45(6):552-6. doi: 10.1111/j.1365-2591.2011.02010.x. Epub 2012 Jan 19.

PMID:
22257341
3.

A comparison between two electronic apex locators: an ex vivo investigation.

Venturi M, Breschi L.

Int Endod J. 2007 May;40(5):362-73. Epub 2007 Feb 19.

PMID:
17309741
4.

Ex Vivo Evaluation of the Accuracy of Electronic Foramen Locators in Root Canals with an Obstructed Apical Foramen.

de Vasconcelos BC, Veríssimo Chaves RD, Vivacqua-Gomes N, Candeiro GT, Bernardes RA, Vivan RR, Duarte MA.

J Endod. 2015 Sep;41(9):1551-4. doi: 10.1016/j.joen.2015.06.009. Epub 2015 Jul 23.

PMID:
26210483
5.

Not all electronic foramen locators are accurate in teeth with enlarged apical foramina: an in vitro comparison of 5 brands.

Akisue E, Gratieri SD, Barletta FB, Caldeira CL, Grazziotin-Soares R, Gavini G.

J Endod. 2014 Jan;40(1):109-12. doi: 10.1016/j.joen.2013.09.032. Epub 2013 Oct 25.

PMID:
24332000
6.

Ex vivo accuracy of three electronic apex locators using different apical file sizes.

Vasconcelos BC, Matos Lde A, Pinheiro-Júnior EC, Menezes AS, Vivacqua-Gomes N.

Braz Dent J. 2012;23(3):199-204.

8.

In vivo assessment of the impedance ratio method used in electronic foramen locators.

Rambo MV, Gamba HR, Borba GB, Maia JM, Ramos CA.

Biomed Eng Online. 2010 Sep 6;9:46. doi: 10.1186/1475-925X-9-46.

9.

Accuracy of Root ZX II in locating foramen in teeth with apical periodontitis: an in vivo study.

Piasecki L, Carneiro E, Fariniuk LF, Westphalen VP, Fiorentin MA, da Silva Neto UX.

J Endod. 2011 Sep;37(9):1213-6. doi: 10.1016/j.joen.2011.06.006. Epub 2011 Jul 20.

PMID:
21846536
10.

Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Vasconcelos BC, Bueno Mde M, Luna-Cruz SM, Duarte MA, Fernandes CA.

J Appl Oral Sci. 2013 Mar-Apr;21(2):132-7. doi: 10.1590/1678-7757201302188.

11.

Influence of Blood on the Accuracy of Raypex 5 and Root ZX Electronic Foramen Locators: An In Vivo Study.

Saatchi M, Aminozarbian MG, Noormohammadi H, Baghaei B.

Braz Dent J. 2016 May-Jun;27(3):336-9. doi: 10.1590/0103-6440201600678.

12.

Ex vivo accuracy of Root ZX II, Root ZX Mini and RomiApex A-15 apex locators in extracted vital pulp teeth.

da Silva TM, Alves FR.

J Contemp Dent Pract. 2014 May 1;15(3):312-4.

PMID:
25307812
13.

Accuracy of a new apex locator: an in vitro study.

Kaufman AY, Keila S, Yoshpe M.

Int Endod J. 2002 Feb;35(2):186-92.

PMID:
11843975
14.

[Accuracy of three different electronic apex locators in determination of perforation with various conditions in vitro].

Li YH, Zhou Z, Zheng YQ, Gan N, Tang YY, Li R, Chen J.

Hua Xi Kou Qiang Yi Xue Za Zhi. 2011 Jun;29(3):272-5. Chinese.

15.

Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study.

Milanovic I, Ivanovic V, Vujaskovic M, Ignjatovic S, Miletic V.

Aust Endod J. 2015 Apr;41(1):35-43. doi: 10.1111/aej.12074. Epub 2014 Sep 4.

PMID:
25195611
16.

Comparison of working length determination with radiographs and two electronic apex locators.

Vieyra JP, Acosta J, Mondaca JM.

Int Endod J. 2010 Jan;43(1):16-20. doi: 10.1111/j.1365-2591.2009.01620.x.

PMID:
20002800
17.

Influence of tooth length on the accuracy of the Root ZX electronic apical foramen locator: an ex vivo study.

Saatchi M, Rahimi I, Khademi A, Farhad AR, Nekoofar MH, Dummer PM.

Acta Odontol Scand. 2015 Feb;73(2):101-6. doi: 10.3109/00016357.2014.956144. Epub 2014 Oct 9.

PMID:
25299599
18.

Ex vivo evaluation of the ability of the ROOT ZX II to locate the apical foramen and to control the apical extent of rotary canal instrumentation.

Felippe WT, Felippe MC, Reyes Carmona J, Crozoé FC, Alvisi BB.

Int Endod J. 2008 Jun;41(6):502-7. doi: 10.1111/j.1365-2591.2008.01386.x. Epub 2008 Mar 19.

PMID:
18363701
19.

Efficacy of Electronic Foramen Locators in Controlling Root Canal Working Length during Rotary Instrumentation.

Parente LA, Levin MD, Vivan RR, Bernardes RA, Duarte MA, Vasconcelos BC.

Braz Dent J. 2015 Oct;26(5):547-51. doi: 10.1590/0103-6440201300099.

20.

In vivo determination of root canal length: a preliminary report using the Tri Auto ZX apex-locating handpiece.

Grimberg F, Banegas G, Chiacchio L, Zmener O.

Int Endod J. 2002 Jul;35(7):590-3.

PMID:
12190898