Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 101

1.

Synchronization sampling method based on delta-sigma analog-digital converter for underwater towed array system.

Jiang JJ, Duan FJ, Li YC, Hua XN.

Rev Sci Instrum. 2014 Mar;85(3):034701. doi: 10.1063/1.4868440.

PMID:
24689606
2.

Digital phased array beamforming using single-bit delta-sigma conversion with non-uniform oversampling.

Kozak M, Karaman M.

IEEE Trans Ultrason Ferroelectr Freq Control. 2001 Jul;48(4):922-31.

PMID:
11477784
3.

A Fast Multiple Sampling Method for Low-Noise CMOS Image Sensors With Column-Parallel 12-bit SAR ADCs.

Kim MK, Hong SK, Kwon OK.

Sensors (Basel). 2015 Dec 26;16(1). pii: E27. doi: 10.3390/s16010027.

4.

Photonic ADC: overcoming the bottleneck of electronic jitter.

Khilo A, Spector SJ, Grein ME, Nejadmalayeri AH, Holzwarth CW, Sander MY, Dahlem MS, Peng MY, Geis MW, DiLello NA, Yoon JU, Motamedi A, Orcutt JS, Wang JP, Sorace-Agaskar CM, Popović MA, Sun J, Zhou GR, Byun H, Chen J, Hoyt JL, Smith HI, Ram RJ, Perrott M, Lyszczarz TM, Ippen EP, Kärtner FX.

Opt Express. 2012 Feb 13;20(4):4454-69. doi: 10.1364/OE.20.004454.

PMID:
22418205
5.

Analysis and compensation of dispersion-induced bit loss in a photonic A/D converter using time-wavelength interweaved sampling clock.

Li M, Wu G, Guo P, Li X, Chen J.

Opt Express. 2009 Sep 28;17(20):17764-71. doi: 10.1364/OE.17.017764.

PMID:
19907563
6.

Low frequency noise elimination technique for 24-bit Σ-Δ data acquisition systems.

Qu SB, Robert O, Lognonné P, Zhou ZB, Yang SQ.

Rev Sci Instrum. 2015 Mar;86(3):034708. doi: 10.1063/1.4914890.

PMID:
25832259
7.

Robust master-slave synchronization for general uncertain delayed dynamical model based on adaptive control scheme.

Wang T, Zhou W, Zhao S, Yu W.

ISA Trans. 2014 Mar;53(2):335-40. doi: 10.1016/j.isatra.2013.11.009. Epub 2014 Jan 21.

PMID:
24461338
8.

Continuous Time Level Crossing Sampling ADC for Bio-Potential Recording Systems.

Tang W, Osman A, Kim D, Goldstein B, Huang C, Martini B, Pieribone VA, Culurciello E.

IEEE Trans Circuits Syst I Regul Pap. 2013 Jun;60(6):1407-1418.

9.

Synchronization Analysis of Master-Slave Probabilistic Boolean Networks.

Lu J, Zhong J, Li L, Ho DW, Cao J.

Sci Rep. 2015 Aug 28;5:13437. doi: 10.1038/srep13437.

10.

Photonic subsampling analog-to-digital conversion of microwave signals at 40-GHz with higher than 7-ENOB resolution.

Kim J, Park MJ, Perrott MH, Kärtner FX.

Opt Express. 2008 Oct 13;16(21):16509-15.

PMID:
18852758
11.

Exponential synchronization of neural networks with discrete and distributed delays under time-varying sampling.

Wu ZG, Shi P, Su H, Chu J.

IEEE Trans Neural Netw Learn Syst. 2012 Sep;23(9):1368-76. doi: 10.1109/TNNLS.2012.2202687.

PMID:
24807922
12.

Analysis on multiple-component synchronization of ultra-fast time-interleaved analog-to-digital conversion systems and its novel parameterized hardware solution.

Huang W, Wang H, Tian S, Ye P, Zeng H, Qiu D.

Rev Sci Instrum. 2014 Oct;85(10):105107. doi: 10.1063/1.4899064.

PMID:
25362456
13.

A 12-bit high-speed column-parallel two-step single-slope analog-to-digital converter (ADC) for CMOS image sensors.

Lyu T, Yao S, Nie K, Xu J.

Sensors (Basel). 2014 Nov 17;14(11):21603-25. doi: 10.3390/s141121603.

14.

Configurable analog-digital conversion using the neural engineering framework.

Mayr CG, Partzsch J, Noack M, Schüffny R.

Front Neurosci. 2014 Jul 22;8:201. doi: 10.3389/fnins.2014.00201. eCollection 2014.

15.

Finite-time master-slave synchronization and parameter identification for uncertain Lurie systems.

Wang T, Zhao S, Zhou W, Yu W.

ISA Trans. 2014 Jul;53(4):1184-90. doi: 10.1016/j.isatra.2014.03.016. Epub 2014 Apr 29.

PMID:
24785822
16.

[The use of sigma-delta analog-digital conversion in multichannel electrocardiographs].

Kurikov SF, Prilutskiĭ DA, Selishchev SV.

Med Tekh. 1997 Jul-Aug;(4):7-10. Russian.

PMID:
9379865
17.

Phasor monitoring of DxPSK signals using software-based synchronization technique.

Choi HG, Takushima Y, Chung YC.

Opt Express. 2010 Oct 11;18(21):21511-8. doi: 10.1364/OE.18.021511.

PMID:
20941048
18.

High-accuracy data acquisition architectures for ultrasonic imaging.

Kalashnikov AN, Ivchenko VG, Challis RE, Hayes-Gill BR.

IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Aug;54(8):1596-605.

PMID:
17703663
19.

Recording human electrocorticographic (ECoG) signals for neuroscientific research and real-time functional cortical mapping.

Hill NJ, Gupta D, Brunner P, Gunduz A, Adamo MA, Ritaccio A, Schalk G.

J Vis Exp. 2012 Jun 26;(64). pii: 3993. doi: 10.3791/3993.

20.

RF Spectrum Sensing Based on an Overdamped Nonlinear Oscillator Ring for Cognitive Radios.

Tang ZL, Li SM, Yu LJ.

Sensors (Basel). 2016 Jun 9;16(6). pii: E844. doi: 10.3390/s16060844.

Items per page

Supplemental Content

Write to the Help Desk