Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 106

1.

[Quality control of dose calibrator using a traceable syringe-type (68)Ge/(68)Ga calibration source].

Miyaji N, Miwa K, Wagatsuma K, Umeda T, Murata T, Takiguchi T, Koizumi M.

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2013 Dec;69(12):1379-86. Japanese.

2.
3.

Quantifying and reducing the effect of calibration error on variability of PET/CT standardized uptake value measurements.

Lockhart CM, MacDonald LR, Alessio AM, McDougald WA, Doot RK, Kinahan PE.

J Nucl Med. 2011 Feb;52(2):218-24. doi: 10.2967/jnumed.110.083865. Epub 2011 Jan 13.

4.

Current status and future needs for standards of radionuclides used in positron emission tomography.

Zimmerman BE.

Appl Radiat Isot. 2013 Jun;76:31-7. doi: 10.1016/j.apradiso.2012.09.011. Epub 2012 Sep 23.

PMID:
23078834
5.

Survey of the performance of commercial dose calibrators for measurement of ¹²³I activity.

Jacobson AF, Centofanti R, Babalola OI, Dean B.

J Nucl Med Technol. 2011 Dec;39(4):302-6. doi: 10.2967/jnmt.111.089235. Epub 2011 Aug 29.

6.

Impact of Recent Change in the National Institute of Standards and Technology Standard for 18F on the Relative Response of 68Ge-Based Mock Syringe Dose Calibrator Standards.

Zimmerman BE, Bergeron DE, Cessna JT.

J Nucl Med. 2015 Sep;56(9):1453-7. doi: 10.2967/jnumed.115.159384. Epub 2015 Jul 16.

PMID:
26182967
7.

A phantom-based method to standardize dose-calibrators for new β+-emitters.

Morgat C, Mazère J, Fernandez P, Buj S, Vimont D, Schulz J, Lamare F.

Nucl Med Commun. 2015 Feb;36(2):201-6. doi: 10.1097/MNM.0000000000000227.

PMID:
25321161
8.

Radioassays and experimental evaluation of dose calibrator settings for 18F.

Zimmerman BE, Kubicek GJ, Cessna JT, Plascjak PS, Eckelman WC.

Appl Radiat Isot. 2001 Jan;54(1):113-22.

PMID:
11144241
9.

Calibration of the Capintec CRC-712M dose calibrator for (18)F.

Mo L, Reinhard MI, Davies JB, Alexiev D, Baldock C.

Appl Radiat Isot. 2006 Apr;64(4):485-9. Epub 2005 Nov 15.

PMID:
16293417
10.

Biases in Multicenter Longitudinal PET Standardized Uptake Value Measurements.

Doot RK, Pierce LA 2nd, Byrd D, Elston B, Allberg KC, Kinahan PE.

Transl Oncol. 2014 Feb 1;7(1):48-54. eCollection 2014 Feb.

11.

Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization.

Lodge MA, Holt DP, Kinahan PE, Wong DF, Wahl RL.

EJNMMI Phys. 2015 May;2. pii: 11. doi: 10.1186/s40658-015-0114-3.

12.

Quantitative online isolation of ⁶⁸Ge from ⁶⁸Ge/⁶⁸Ga generator eluates for purification and immediate quality control of breakthrough.

Eppard E, Loktionova NS, Rösch F.

Appl Radiat Isot. 2013 Dec;82:45-8. doi: 10.1016/j.apradiso.2013.07.020. Epub 2013 Jul 25.

PMID:
23948310
13.

A recommendation for revised dose calibrator measurement procedures for 89Zr and 124I.

Beattie BJ, Pentlow KS, O'Donoghue J, Humm JL.

PLoS One. 2014 Sep 9;9(9):e106868. doi: 10.1371/journal.pone.0106868. eCollection 2014.

14.

A practical method of determining cross-calibration factors of PET scanners by moving a point-like (22)Na radioactive source.

Hasegawa T, Oda K, Wada Y, Sato Y, Yamada T, Yoshida E, Murayama H, Saito K, Takeda T, Kikuchi K.

Ann Nucl Med. 2010 Nov;24(9):655-61. doi: 10.1007/s12149-010-0403-9. Epub 2010 Aug 11.

PMID:
20700667
15.

Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources.

Baltas D, Geramani K, Ioannidis GT, Hierholz K, Rogge B, Kolotas C, Müller-Sievers K, Milickovic N, Kober B, Zamboglou N.

Int J Radiat Oncol Biol Phys. 1999 Feb 1;43(3):653-61.

PMID:
10078653
16.
17.

Accurate dose calibrator activity measurement of 90Y-ibritumomab tiuxetan.

Siegel JA, Zimmerman BE, Kodimer K, Dell MA, Simon WE.

J Nucl Med. 2004 Mar;45(3):450-4.

18.

⁶⁸Ge content quality control of ⁶⁸Ge/⁶⁸Ga-generator eluates and ⁶⁸Ga radiopharmaceuticals--a protocol for determining the ⁶⁸Ge content using thin-layer chromatography.

Eppard E, Loktionova NS, Rösch F.

Appl Radiat Isot. 2014 Sep;91:92-6. doi: 10.1016/j.apradiso.2014.05.011. Epub 2014 May 24.

PMID:
24922553
19.

[Comparison of activity expression between PET using 68Ge-68Ga line source attenuation correction and PET-CT using CT attenuation correction: impact on emission images].

Hayashi E, Iwase M, Kojima S, Nishio M.

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2006 Jun 20;62(6):832-9. Japanese.

PMID:
16799411
20.
Items per page

Supplemental Content

Write to the Help Desk