Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 99

Related Citations for PubMed (Select 24353388)

1.

Image acquisition, geometric correction and display of images from a 2×2 x-ray detector array based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Vasan SN, Sharma P, Ionita CN, Titus AH, Cartwright AN, Bednarek DR, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2013 Mar 6;8668. doi: 10.1117/12.2006280.

2.

Novel Multiplexer to Enable Multiple-Module Imaging with Adjustable High Spatial Resolution and Predetermined Display Bandwidth for Array Medical Imaging Systems.

Sharma P, Titus AH, Qu B, Huang Y, Wang W, Kuhls-Gilcrist A, Cartwright AN, Bednarek DR, Rudin S.

IEEE Nucl Sci Symp Conf Rec (1997). 2010:2134-2137.

3.

Quantitative analysis of an enlarged area Solid State X-ray Image Intensifier (SSXII) detector based on Electron Multiplying Charge Coupled Device (EMCCD) technology.

Swetadri VS, Sharma P, Singh V, Jain A, Ionita CN, Titus AH, Cartwright AN, Bednarek DR, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2013 Mar 6;8668. doi: 10.1117/12.2006286.

4.

Implementation of digital multiplexing for high resolution X-ray detector arrays.

Sharma P, Swetadri Vasan SN, Titus AH, Cartwright AN, Bednarek DR, Rudin S.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:5979-82. doi: 10.1109/EMBC.2012.6347356.

PMID:
23367291
5.

Graphical User Interface for a Dual-Module EMCCD X-ray Detector Array.

Wang W, Ionita C, Kuhls-Gilcrist A, Huang Y, Qu B, Gupta SK, Bednarek DR, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2011 Mar 16;7961. doi: 10.1117/12.877588.

6.

A 2×2 array of EMCCD-based solid state x-ray detectors.

Sharma P, Swetadri Vasan SN, Titus AH, Cartwright AN, Bednarek DR, Rudin S.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:5983-6. doi: 10.1109/EMBC.2012.6347357.

PMID:
23367292
7.

Real-time implementation of distortion corrections for a tiled EMCCD-based Solid State X-ray Image Intensifier (SSXII).

Keleshis C, Hoffmann K, Lee J, Hamwi H, Wang W, Ionita C, Bednarek D, Verevkin A, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2009 Jan 1;7258:72583B1-72583B11.

8.

Distortion, Orientation, and Translation Corrections of Tiled EMCCD Detectors for the New Solid State X-ray Image Intensifier (SSXII).

Hamwi H, Lee JW, Hoffmann KR, Rudin S, Verevkin A.

Proc Soc Photo Opt Instrum Eng. 2008;6913:69133T.

10.

Image geometric corrections for a new EMCCD-based dual modular x-ray imager.

Qu B, Huang Y, Wang W, Cartwright AN, Titus AH, Bednarek DR, Rudin S.

Conf Proc IEEE Eng Med Biol Soc. 2011;2011:2634-7. doi: 10.1109/IEMBS.2011.6090726.

11.

Two dimensional extensible array configuration for EMCCD-based solid state x-ray detectors.

Sharma P, Vasan SN, Cartwright AN, Titus AH, Bednarek DR, Rudin S.

Proc SPIE. 2012;8313:83135A. Epub 2012 Mar 2.

12.

EMCCD-based high resolution dynamic x-ray detector for neurovascular interventions.

Sharma P, Vasan SN, Jain A, Panse A, Titus AH, Cartwright AN, Bednarek DR, Rudin S.

Conf Proc IEEE Eng Med Biol Soc. 2011;2011:7787-90. doi: 10.1109/IEMBS.2011.6091919.

13.

Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.

Kuhls AT, Yadava G, Patel V, Bednarek DR, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2007;6510(1):65101C.

14.

Optical Demonstration of a Medical Imaging System with an EMCCD-Sensor Array for Use in a High Resolution Dynamic X-ray Imager.

Qu B, Huang Y, Wang W, Sharma P, Kuhls-Gilcrist AT, Cartwright AN, Titus AH, Bednarek DR, Rudin S.

IEEE Nucl Sci Symp Conf Rec (1997). 2010 Oct 30;2010:2607-2609.

15.

The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD-Based X-Ray Detector.

Kuhls-Gilcrist A, Yadava G, Patel V, Jain A, Bednarek DR, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2008;6913:69130K.

16.

Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Ionita CN, Keleshis C, Patel V, Yadava G, Hoffmann KR, Bednarek DR, Jain A, Rudin S.

Proc Soc Photo Opt Instrum Eng. 2008;6918:69181I.

17.

Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA.

Int J Radiat Oncol Biol Phys. 2002 Aug 1;53(5):1337-49.

PMID:
12128137
18.
19.

A 3 x 6 arrayed CCD X-ray detector for continuous rotation method in macromolecular crystallography.

Ito K, Gaponov Y, Sakabe N, Amemiya Y.

J Synchrotron Radiat. 2007 Jan;14(Pt 1):144-50. Epub 2006 Dec 15.

PMID:
17211082
20.

Analysis of the detective quantum efficiency of a developmental detector for digital mammography.

Williams MB, Simoni PU, Smilowitz L, Stanton M, Phillips W, Stewart A.

Med Phys. 1999 Nov;26(11):2273-85.

PMID:
10587208
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk