Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 148

Related Citations for PubMed (Select 24320447)

1.

CONRAD--a software framework for cone-beam imaging in radiology.

Maier A, Hofmann HG, Berger M, Fischer P, Schwemmer C, Wu H, Müller K, Hornegger J, Choi JH, Riess C, Keil A, Fahrig R.

Med Phys. 2013 Nov;40(11):111914. doi: 10.1118/1.4824926.

2.

A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections.

Jia X, Yan H, Cervino L, Folkerts M, Jiang SB.

Med Phys. 2012 Dec;39(12):7368-78. doi: 10.1118/1.4766436.

3.

Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

Ahmad M, Balter P, Pan T.

Med Phys. 2011 Oct;38(10):5646-56. doi: 10.1118/1.3634058.

4.

SNARK09 - a software package for reconstruction of 2D images from 1D projections.

Klukowska J, Davidi R, Herman GT.

Comput Methods Programs Biomed. 2013 Jun;110(3):424-40. doi: 10.1016/j.cmpb.2013.01.003. Epub 2013 Feb 13.

PMID:
23414602
5.

Directional interpolation for motion weighted 4D cone-beam CT reconstruction.

Zhang H, Sonke JJ.

Med Image Comput Comput Assist Interv. 2012;15(Pt 1):181-8.

PMID:
23285550
6.

A fast forward projection using multithreads for multirays on GPUs in medical image reconstruction.

Chou CY, Chuo YY, Hung Y, Wang W.

Med Phys. 2011 Jul;38(7):4052-65.

PMID:
21859004
7.

Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions.

Isola AA, Ziegler A, Koehler T, Niessen WJ, Grass M.

Phys Med Biol. 2008 Dec 7;53(23):6777-97. doi: 10.1088/0031-9155/53/23/009. Epub 2008 Nov 7.

PMID:
18997267
8.

Physical phantom studies of helical cone-beam CT with exact reconstruction.

Tan J, Li HH, Klein E, Li H, Parikh P, Yang D.

Med Phys. 2012 Aug;39(8):4695-704. doi: 10.1118/1.4736535.

PMID:
22894394
9.

Fast polyenergetic forward projection for image formation using OpenCL on a heterogeneous parallel computing platform.

Zhou L, Clifford Chao KS, Chang J.

Med Phys. 2012 Nov;39(11):6745-56. doi: 10.1118/1.4758062.

PMID:
23127068
10.

A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube.

Xu X, Kim J, Laganis P, Schulze D, Liang Y, Zhang T.

Med Phys. 2011 Oct;38(10):5500-8. doi: 10.1118/1.3634043.

11.

Fully 3D iterative CT reconstruction using polar coordinates.

Thibaudeau C, Leroux JD, Fontaine R, Lecomte R.

Med Phys. 2013 Nov;40(11):111904. doi: 10.1118/1.4822514.

PMID:
24320437
12.

Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images.

Wang L, Chen X, Lin MH, Xue J, Lin T, Fan J, Jin L, Ma CM.

Med Phys. 2013 Nov;40(11):111709. doi: 10.1118/1.4823785.

PMID:
24320417
13.

A program for medical visualization and image processing.

Zaffari CA, Zaffari P, de Azevedo DF, Russomano T, Helegda S, Figueira MV.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:5790-3.

PMID:
17947167
14.

Technical note: RabbitCT--an open platform for benchmarking 3D cone-beam reconstruction algorithms.

Rohkohl C, Keck B, Hofmann HG, Hornegger J.

Med Phys. 2009 Sep;36(9):3940-4.

PMID:
19810466
15.

Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware.

Kole JS, Beekman FJ.

Phys Med Biol. 2006 Feb 21;51(4):875-89. Epub 2006 Jan 25.

PMID:
16467584
16.

Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Qi Z, Chen GH.

Med Phys. 2011 Oct;38(10):5530-8. doi: 10.1118/1.3637501.

17.

High performance computing for deformable image registration: towards a new paradigm in adaptive radiotherapy.

Samant SS, Xia J, Muyan-Ozcelik P, Owens JD.

Med Phys. 2008 Aug;35(8):3546-53.

PMID:
18777915
18.

Motion-map constrained image reconstruction (MCIR): application to four-dimensional cone-beam computed tomography.

Park JC, Kim JS, Park SH, Liu Z, Song B, Song WY.

Med Phys. 2013 Dec;40(12):121710. doi: 10.1118/1.4829504.

PMID:
24320496
19.

Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Sidky EY, Pan X.

Phys Med Biol. 2008 Sep 7;53(17):4777-807. doi: 10.1088/0031-9155/53/17/021. Epub 2008 Aug 13.

20.

Accelerating reconstruction of reference digital tomosynthesis using graphics hardware.

Yan H, Ren L, Godfrey DJ, Yin FF.

Med Phys. 2007 Oct;34(10):3768-76.

PMID:
17985622
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk