1.

Timing and source of the maximum of the transthoracic impedance cardiogram (dZ/dt) in relation to the H-I-J complex of the longitudinal ballistocardiogram under gravity and microgravity conditions.

Luchitskaya E, Deliere Q, Diedrich A, Pattyn N, Almorad A, Beck L, Gauger P, Limper U, Funtova I, Baevsky RM, Migeotte PF, Tank J.

Conf Proc IEEE Eng Med Biol Soc. 2013;2013:7294-7. doi: 10.1109/EMBC.2013.6611242.

PMID:
24111429
[PubMed - in process]
2.

Cardiovascular changes in parabolic flights assessed by ballistocardiography.

Delière Q, Migeotte PF, Neyt X, Funtova I, Baevsky RM, Tank J, Pattyn N.

Conf Proc IEEE Eng Med Biol Soc. 2013;2013:3801-4. doi: 10.1109/EMBC.2013.6610372.

PMID:
24110559
[PubMed - in process]
3.

Signal fidelity requirements for deriving impedance cardiographic measures of cardiac function over a broad heart rate range.

Hurwitz BE, Shyu LY, Lu CC, Reddy SP, Schneiderman N, Nagel JH.

Biol Psychol. 1993 Aug;36(1-2):3-21.

PMID:
8218621
[PubMed - indexed for MEDLINE]
4.

The transthoracic impedance cardiogram is a potential haemodynamic sensor for an automated external defibrillator.

Johnston PW, Imam Z, Dempsey G, Anderson J, Adgey AA.

Eur Heart J. 1998 Dec;19(12):1879-88. Erratum in: Eur Heart J 1999 Mar;20(6):472.

PMID:
9886732
[PubMed - indexed for MEDLINE]
Free Article
5.

The effect of acute aortic regurgitation on the transthoracic impedance cardiogram.

Schieken RM, Patel MR, Falsetti HL.

Cathet Cardiovasc Diagn. 1980;6(1):61-71.

PMID:
7363319
[PubMed - indexed for MEDLINE]
6.

Comparative measures of systolic ejection during treadmill exercise by impedance cardiography and Doppler echocardiography.

Kizakevich PN, Teague SM, Nissman DB, Jochem WJ, Niclou R, Sharma MK.

Biol Psychol. 1993 Aug;36(1-2):51-61.

PMID:
8218624
[PubMed - indexed for MEDLINE]
7.

Beat-to-beat evaluation of systolic time intervals during bicycle exercise using impedance cardiography.

Ono T, Miyamura M, Yasuda Y, Ito T, Saito T, Ishiguro T, Yoshizawa M, Yambe T.

Tohoku J Exp Med. 2004 May;203(1):17-29.

PMID:
15185968
[PubMed - indexed for MEDLINE]
Free Article
8.

A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise.

Kim DW, Song CG, Lee MH.

Front Med Biol Eng. 1992;4(3):179-88.

PMID:
1419917
[PubMed - indexed for MEDLINE]
9.

Assessment of the impedance cardiogram recorded by an automated external defibrillator during clinical cardiac arrest.

Cromie NA, Allen JD, Navarro C, Turner C, Anderson JM, Adgey AA.

Crit Care Med. 2010 Feb;38(2):510-7. doi: 10.1097/CCM.0b013e3181c02ca1.

PMID:
19864942
[PubMed - indexed for MEDLINE]
10.

The impedance cardiogram recorded through two electrocardiogram/defibrillator pads as a determinant of cardiac arrest during experimental studies.

Cromie NA, Allen JD, Turner C, Anderson JM, Adgey AA.

Crit Care Med. 2008 May;36(5):1578-84. doi: 10.1097/CCM.0b013e318170a03b.

PMID:
18434896
[PubMed - indexed for MEDLINE]
11.

Effect of mitral valvular regurgitation on transthoracic impedance cardiogram.

Schieken RM, Patel MR, Falsetti HL, Lauer RM.

Br Heart J. 1981 Feb;45(2):166-72.

PMID:
6109542
[PubMed - indexed for MEDLINE]
Free PMC Article
12.

3D-ballistocardiography in microgravity: comparison with ground based recordings.

Migeotte PF, Delière Q, Tank J, Funtova I, Baevsky R, Neyt X, Pattyn N.

Conf Proc IEEE Eng Med Biol Soc. 2013;2013:7012-6. doi: 10.1109/EMBC.2013.6611172.

PMID:
24111359
[PubMed - in process]
13.

An improved approach for measurement of stroke volume during treadmill exercise.

Song CG, Kim DW.

Med Eng Phys. 2003 Jul;25(6):517-22.

PMID:
12787990
[PubMed - indexed for MEDLINE]
14.

Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram.

Inan OT, Etemadi M, Wiard RM, Kovacs GT, Giovangrandi L.

Conf Proc IEEE Eng Med Biol Soc. 2009;2009:5344-47. doi: 10.1109/IEMBS.2009.5333709.

PMID:
19964385
[PubMed - indexed for MEDLINE]
15.

Theory of the determination of systolic time intervals by impedance cardiography.

Visser KR, Mook GA, van der Wall E, Zijlstra WG.

Biol Psychol. 1993 Aug;36(1-2):43-50.

PMID:
8218623
[PubMed - indexed for MEDLINE]
16.

Stability of cardiac impedance measures: aortic opening (B-point) detection and scoring.

Debski TT, Zhang Y, Jennings JR, Kamarck TW.

Biol Psychol. 1993 Aug;36(1-2):63-74.

PMID:
8218625
[PubMed - indexed for MEDLINE]
17.

Computer determination of systolic time intervals based on impedance cardiography.

Szilágyi N, Láng E, Balázs L.

Int J Psychophysiol. 1992 Jul;13(1):45-9.

PMID:
1522032
[PubMed - indexed for MEDLINE]
18.

Gender and age differences in transthoracic bioimpedance.

Metry G, Wikström B, Linde T, Danielson BG.

Acta Physiol Scand. 1997 Oct;161(2):171-5.

PMID:
9366959
[PubMed - indexed for MEDLINE]
19.

Hemodynamic evaluation in pregnancy: limitations of impedance cardiography.

Moertl MG, Schlembach D, Papousek I, Hinghofer-Szalkay H, Weiss EM, Lang U, Lackner HK.

Physiol Meas. 2012 Jun;33(6):1015-26. doi: 10.1088/0967-3334/33/6/1015. Epub 2012 May 4.

PMID:
22562970
[PubMed - indexed for MEDLINE]
20.

Three-dimensional ballistocardiography and respiratory motion in sustained microgravity.

Prisk GK, Verhaeghe S, Padeken D, Hamacher H, Paiva M.

Aviat Space Environ Med. 2001 Dec;72(12):1067-74.

PMID:
11763106
[PubMed - indexed for MEDLINE]