1.

Shock whilst gardening--implantable defibrillators & lawn mowers.

Von Olshausen G, Lennerz C, Grebmer C, Pavaci H, Kolb C.

QJM. 2014 Feb;107(2):147-9. doi: 10.1093/qjmed/hct180. Epub 2013 Sep 9.

PMID:
24023069
[PubMed - indexed for MEDLINE]
2.

Inappropriate shock delivery due to interference between a washing machine and an implantable cardioverter defibrillator.

Kolb C, Schmieder S, Schmitt C.

J Interv Card Electrophysiol. 2002 Dec;7(3):255-6.

PMID:
12510137
[PubMed - indexed for MEDLINE]
3.

Electromagnetic interference from electronic article surveillance system in a patient with a biventricular ICD and a left ventricular assist device.

Koneru JN, Dumitru I, Easley AR Jr.

Pacing Clin Electrophysiol. 2011 Feb;34(2):244-6. doi: 10.1111/j.1540-8159.2010.02842.x. Epub 2010 Aug 18. No abstract available.

PMID:
20727104
[PubMed - indexed for MEDLINE]
4.

Lightning induced inappropriate ICD shock: an unusual case of electromagnetic interference.

Anderson DR, Gillberg JM, Torrey JW, Koneru JN.

Pacing Clin Electrophysiol. 2012 Jun;35(6):e159-62. doi: 10.1111/j.1540-8159.2010.02914.x. Epub 2010 Sep 30.

PMID:
20883513
[PubMed - indexed for MEDLINE]
5.

Induction of ventricular tachycardia by alternate current due to an insufficiently grounded electrical system.

Lappegård KT.

Pacing Clin Electrophysiol. 2012 Jun;35(6):e170-2. doi: 10.1111/j.1540-8159.2010.02964.x. Epub 2010 Nov 17.

PMID:
21091734
[PubMed - indexed for MEDLINE]
6.

Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.

Chongtham DS, Bahl A, Kumar RM, Talwar KK.

Int J Cardiol. 2007 May 31;118(2):e44-5. Epub 2007 Mar 28.

PMID:
17395291
[PubMed - indexed for MEDLINE]
7.

Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy.

Siu CW, Tse HF, Lau CP.

J Interv Card Electrophysiol. 2005 Jun;13(1):73-5.

PMID:
15976983
[PubMed - indexed for MEDLINE]
8.

Implantable cardioverter defibrillator-an unusual case of inappropriate discharge during showering.

Manolis AG, Katsivas AG, Vassilopoulos CV, Louvros NE.

J Interv Card Electrophysiol. 2000 Apr;4(1):265-8.

PMID:
10729845
[PubMed - indexed for MEDLINE]
9.

Electromagnetic interference with implantable cardioverter-defibrillators at power frequency: an in vivo study.

Napp A, Joosten S, Stunder D, Knackstedt C, Zink M, Bellmann B, Marx N, Schauerte P, Silny J.

Circulation. 2014 Jan 28;129(4):441-50. doi: 10.1161/CIRCULATIONAHA.113.003081. Epub 2013 Oct 25.

PMID:
24163067
[PubMed - indexed for MEDLINE]
10.

Fish pond electromagnetic interference resulting in an inappropriate implantable cardioverter defibrillator shock.

Vlay SC.

Pacing Clin Electrophysiol. 2002 Oct;25(10):1532. No abstract available.

PMID:
12418756
[PubMed - indexed for MEDLINE]
11.

Intermittent, erratic behaviour of an implantable cardioverter defibrillator secondary to a hidden magnetic source of interference.

Beinart R, Guy ML, Ellinor PT.

Europace. 2011 Oct;13(10):1508-9. doi: 10.1093/europace/eur152. Epub 2011 May 15.

PMID:
21576126
[PubMed - indexed for MEDLINE]
Free PMC Article
12.

"Magnetic attraction" in the pediatric emergency department: the case of a malfunctioning implantable cardioverter-defibrillator.

Ladouceur VB, Khairy P, Béland MJ, Bhanji F.

Pediatr Emerg Care. 2012 Jun;28(6):562-5. doi: 10.1097/PEC.0b013e318258be04.

PMID:
22668661
[PubMed - indexed for MEDLINE]
13.

Pacing-dependency following implantable cardioverter-defibrillator shocks: a case report.

Webber MR, Levings SL, Stiles MK.

J Electrocardiol. 2013 Mar-Apr;46(2):142-4. doi: 10.1016/j.jelectrocard.2012.10.008. Epub 2012 Nov 22.

PMID:
23177276
[PubMed - indexed for MEDLINE]
14.

Implantable cardioverter-defibrillator shock during physical activity: appropriate or inappropriate shock?

Chemello D, Chin A, Morillo C, Divakaramenon S.

Pacing Clin Electrophysiol. 2013 May;36(5):635-8. doi: 10.1111/pace.12038. Epub 2012 Nov 5. No abstract available.

PMID:
23127226
[PubMed - indexed for MEDLINE]
15.

In vitro tests reveal sample radiofrequency identification readers inducing clinically significant electromagnetic interference to implantable pacemakers and implantable cardioverter-defibrillators.

Seidman SJ, Brockman R, Lewis BM, Guag J, Shein MJ, Clement WJ, Kippola J, Digby D, Barber C, Huntwork D.

Heart Rhythm. 2010 Jan;7(1):99-107. doi: 10.1016/j.hrthm.2009.09.071. Epub 2009 Oct 12.

PMID:
20129290
[PubMed - indexed for MEDLINE]
16.

Inappropriate implantable cardioverter defibrillator discharge from sensing of external alternating current leak.

Garg A, Wadhwa M, Brown K, Luckett C, Vaughn T, Birgersdotter-Green U, Feld G.

J Interv Card Electrophysiol. 2002 Oct;7(2):181-4.

PMID:
12397229
[PubMed - indexed for MEDLINE]
17.

Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.

Ueda-Tatsumoto A, Fukamizu S, Nishizaki M, Sakurada H, Hiraoka M.

Pacing Clin Electrophysiol. 2009 Nov;32(11):1481-4. doi: 10.1111/j.1540-8159.2009.02518.x. Epub 2009 Aug 27.

PMID:
19712072
[PubMed - indexed for MEDLINE]
18.

Renal artery thrombosis following an inappropriate implantable cardioverter defibrillator shock.

Arias MA, DE LA Rosa C, Puchol A, Rodríguez-Padial L.

Pacing Clin Electrophysiol. 2012 Sep;35(9):e263-4. doi: 10.1111/j.1540-8159.2011.03180.x. Epub 2011 Jul 28.

PMID:
21797905
[PubMed - indexed for MEDLINE]
19.

Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.

Farwell D, Redpath C, Birnie D, Gollob M, Lemery R, Posan E, Green M.

Europace. 2008 Jun;10(6):726-8. doi: 10.1093/europace/eun113. Epub 2008 May 1.

PMID:
18456645
[PubMed - indexed for MEDLINE]
Free Article
20.

ICD and neuromodulation devices: is peaceful coexistence possible?

Molon G, Perrone C, Maines M, Costa A, Comisso J, Boi A, Moro E, Vergara G, Barbieri E.

Pacing Clin Electrophysiol. 2011 Jun;34(6):690-3. doi: 10.1111/j.1540-8159.2011.03036.x. Epub 2011 Feb 8.

PMID:
21303391
[PubMed - indexed for MEDLINE]