Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 96

Similar articles for PubMed (Select 24021745)

1.

Improved Cole parameter extraction based on the least absolute deviation method.

Yang Y, Ni W, Sun Q, Wen H, Teng Z.

Physiol Meas. 2013 Oct;34(10):1239-52. doi: 10.1088/0967-3334/34/10/1239. Epub 2013 Sep 11.

PMID:
24021745
2.

Cole parameter estimation from electrical bioconductance spectroscopy measurements.

Seoane F, Buendia R, Gil-Pita R.

Conf Proc IEEE Eng Med Biol Soc. 2010;2010:3495-8. doi: 10.1109/IEMBS.2010.5627790.

PMID:
21097029
3.

Electrical properties of human skin as aging biomarkers.

Simić-Krstić JB, Kalauzi AJ, Ribar SN, Matija LR, Misevic GN.

Exp Gerontol. 2014 Sep;57:163-7. doi: 10.1016/j.exger.2014.06.001. Epub 2014 Jun 3.

PMID:
24905143
4.

Cole equation and parameter estimation from electrical bioimpedance spectroscopy measurements - A comparative study.

Ayllon D, Seoane F, Gil-Pita R.

Conf Proc IEEE Eng Med Biol Soc. 2009;2009:3779-82. doi: 10.1109/IEMBS.2009.5334494.

PMID:
19964815
5.

Cole parameter estimation from total right side electrical bioimpedance spectroscopy measurements--influence of the number of frequencies and the upper limit.

Buendía R, Gil-Pita R, Seoane F.

Conf Proc IEEE Eng Med Biol Soc. 2011;2011:1843-6. doi: 10.1109/IEMBS.2011.6090524.

PMID:
22254688
6.

Preprocessing and parameterizing bioimpedance spectroscopy measurements by singular value decomposition.

Nejadgholi I, Caytak H, Bolic M, Batkin I, Shirmohammadi S.

Physiol Meas. 2015 May;36(5):983-99. doi: 10.1088/0967-3334/36/5/983. Epub 2015 Apr 20.

PMID:
25893319
7.

Influence of electrode mismatch on Cole parameter estimation from total right side electrical bioimpedance spectroscopy measurements.

Buendía R, Bogónez-Franco P, Nescolarde L, Seoane F.

Med Eng Phys. 2012 Sep;34(7):1024-8. doi: 10.1016/j.medengphy.2012.05.011. Epub 2012 Jun 26.

PMID:
22738873
8.
9.

Extracting the parameters of the double-dispersion Cole bioimpedance model from magnitude response measurements.

Freeborn TJ, Maundy B, Elwakil AS.

Med Biol Eng Comput. 2014 Sep;52(9):749-58. doi: 10.1007/s11517-014-1175-5. Epub 2014 Jul 15.

PMID:
25023892
10.

A program for the fitting of Debye, Cole-Cole, Cole-Davidson, and Havriliak-Negami dispersions to dielectric data.

Grosse C.

J Colloid Interface Sci. 2014 Apr 1;419:102-6. doi: 10.1016/j.jcis.2013.12.031. Epub 2013 Dec 23.

PMID:
24491337
11.
12.

Adaptive frequency distribution for electrical bioimpedance spectroscopy measurements.

Seoane F, Ferreira J, Buendia R, Lindecrantz K.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:562-5. doi: 10.1109/EMBC.2012.6345993.

PMID:
23365954
13.

Automated criterion-based analysis for Cole parameters assessment from cerebral neonatal electrical bioimpedance spectroscopy measurements.

Seoane F, Ward LC, Lindecrantz K, Lingwood BE.

Physiol Meas. 2012 Aug;33(8):1363-77. doi: 10.1088/0967-3334/33/8/1363. Epub 2012 Jul 25.

PMID:
22828035
14.

A generalized least absolute deviation method for parameter estimation of autoregressive signals.

Xia Y, Kamel MS.

IEEE Trans Neural Netw. 2008 Jan;19(1):107-18. doi: 10.1109/TNN.2007.902962.

PMID:
18269942
15.

Constrained least absolute deviation neural networks.

Wang Z, Peterson BS.

IEEE Trans Neural Netw. 2008 Feb;19(2):273-83. doi: 10.1109/TNN.2007.905840.

16.

Application of dielectric spectroscopy for monitoring high cell density in monoclonal antibody producing CHO cell cultivations.

Párta L, Zalai D, Borbély S, Putics A.

Bioprocess Biosyst Eng. 2014 Feb;37(2):311-23. doi: 10.1007/s00449-013-0998-z. Epub 2013 Jun 26.

PMID:
23801499
17.

Robust time delay estimation of bioelectric signals using least absolute deviation neural network.

Wang Z, He Z, Chen JD.

IEEE Trans Biomed Eng. 2005 Mar;52(3):454-62.

PMID:
15759575
18.

Hook effect correction & resistance-based cole fitting prior cole model-based analysis: experimental validation.

Buendia R, Seoane F, Harris M, Caffarel J, Gil R.

Conf Proc IEEE Eng Med Biol Soc. 2010;2010:6563-6. doi: 10.1109/IEMBS.2010.5627109.

PMID:
21096507
19.
20.

Evaluation of algorithms for calculating bioimpedance phase angle values from measured whole-body impedance modulus.

Nordbotten BJ, Tronstad C, Martinsen Ø, Grimnes S.

Physiol Meas. 2011 Jul;32(7):755-65. doi: 10.1088/0967-3334/32/7/S03. Epub 2011 Jun 7.

PMID:
21646707
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk