Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 104

Similar articles for PubMed (Select 23980924)

1.

Shock-induced ventricular tachycardia: what is the mechanism?

Santangeli P, Hsia HH, Wang PJ, Al-Ahmad A.

Pacing Clin Electrophysiol. 2014 Apr;37(4):516-9. doi: 10.1111/pace.12244. Epub 2013 Aug 26. No abstract available.

PMID:
23980924
2.

A "shocking" case rectified.

Van Heuverswyn F, Timmers L, Combes M, Stroobandt R.

Pacing Clin Electrophysiol. 2014 Mar;37(3):379-82. doi: 10.1111/pace.12226. Epub 2013 Jul 22. No abstract available.

PMID:
23875996
3.

Single and inappropriate shock delivered out of tachycardia: device dysfunction?

Fontenla A, Carrero D, Salguero R, López-Gil M, De Riva M, Arribas F.

Pacing Clin Electrophysiol. 2012 Jul;35(7):884-6. doi: 10.1111/j.1540-8159.2011.03302.x. Epub 2012 Jan 16. No abstract available.

PMID:
22248372
4.

Troubleshooting of small R-wave with inappropriate implantable cardioverter-defibrillator shock.

Baldinger SH, Kadner A, Delacrétaz E.

Europace. 2014 Jun;16(6):854. doi: 10.1093/europace/eut266. Epub 2013 Sep 5. No abstract available.

5.

Induction of ventricular tachycardia by alternate current due to an insufficiently grounded electrical system.

Lappegård KT.

Pacing Clin Electrophysiol. 2012 Jun;35(6):e170-2. doi: 10.1111/j.1540-8159.2010.02964.x. Epub 2010 Nov 17.

PMID:
21091734
6.

Inappropriate shocks or inappropriate programming? A review of Guidant's reconfirmation algorithm.

Mansour F, Guash E, Berruezo A, Brugada J, Tolosana JM, Mont L.

Europace. 2009 Aug;11(8):1120-2. doi: 10.1093/europace/eup116. Epub 2009 May 13.

7.

ICD proarrhythmia as a consequence of an interaction with an algorithm to prevent atrial arrhythmias.

Martínez-Sánchez J, García-Alberola A, Sánchez-Muñoz JJ, Peñafiel-Verdú P, Giner-Caro JA, Valdés-Chávarri M.

Pacing Clin Electrophysiol. 2009 Aug;32(8):1096-8. doi: 10.1111/j.1540-8159.2009.02444.x.

PMID:
19659632
8.

Hazards of antitachycardia pacing to treat ventricular tachycardias with implantable cardioverter defibrillators.

Maass AH, Van Gelder IC.

Europace. 2009 Jun;11(6):819. doi: 10.1093/europace/eup080. Epub 2009 Apr 8. No abstract available.

9.

Home Monitoring in an ICD patient with incessant ventricular tachycardia.

Koos R, Sinha AM, Stellbrink C.

Z Kardiol. 2005 Jul;94(7):461-4.

PMID:
15997347
10.

A new mechanism for inappropriate therapy observed during recommended device software upgrade of a St Jude Medical Fortify ST™ implantable cardioverter-defibrillator.

Sandgaard NC, Johansen JB.

Europace. 2014 Jan;16(1):80. doi: 10.1093/europace/eut209. Epub 2013 Jul 14. No abstract available.

11.

ICD arrhythmia detection and discrimination: are we there yet?

Kenigsberg DN, Ellenbogen KA.

J Cardiovasc Electrophysiol. 2006 Dec;17(12):1320-2. Epub 2006 Nov 1. No abstract available.

PMID:
17081200
12.

Unusual manifestation of upper rate limitation in a dual-chamber ICD.

Barold SS, Stroobandt RX, Herweg B.

Pacing Clin Electrophysiol. 2012 Jul;35(7):880-3. doi: 10.1111/j.1540-8159.2011.03301.x. Epub 2012 Jan 9. No abstract available.

PMID:
22229539
13.

Why did the ICD indicate "terminate" during ongoing tachycardia?

Modi S, Angaran P, Klein GJ, Leong-Sit P.

Pacing Clin Electrophysiol. 2012 Feb;35(2):230-2. doi: 10.1111/j.1540-8159.2011.03113.x. Epub 2011 Apr 28. No abstract available.

PMID:
21535036
14.

Pacing-dependency following implantable cardioverter-defibrillator shocks: a case report.

Webber MR, Levings SL, Stiles MK.

J Electrocardiol. 2013 Mar-Apr;46(2):142-4. doi: 10.1016/j.jelectrocard.2012.10.008. Epub 2012 Nov 22.

PMID:
23177276
15.

Making sense of the new ICD algorithms for the treatment of fast ventricular tachycardia.

Barold SS, Herweg B.

Pacing Clin Electrophysiol. 2009 Feb;32(2):149-52. doi: 10.1111/j.1540-8159.2008.02195.x. No abstract available.

PMID:
19170901
17.

Identifying non-inducible ventricular tachycardia origin utilizing defibrillator electrograms.

Tschabrunn CM, Anter E, Marchlinski FE.

J Interv Card Electrophysiol. 2013 Apr;36(3):243-6. doi: 10.1007/s10840-012-9731-0. Epub 2012 Oct 27.

PMID:
23104050
18.

Lightning induced inappropriate ICD shock: an unusual case of electromagnetic interference.

Anderson DR, Gillberg JM, Torrey JW, Koneru JN.

Pacing Clin Electrophysiol. 2012 Jun;35(6):e159-62. doi: 10.1111/j.1540-8159.2010.02914.x. Epub 2010 Sep 30.

PMID:
20883513
19.
20.

A covariance-based algorithm: a novel technique for rhythm discrimination in ICDs.

Kamousi B, Lin B, Al-Ahmad A, Hsia H, Zei P, Natale A, Moss A, Daubert J, Zareba W, Wang P.

Conf Proc IEEE Eng Med Biol Soc. 2008;2008:5478-81. doi: 10.1109/IEMBS.2008.4650454.

PMID:
19163957
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk