Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 111

2.

[Application of collimator broad correction three dimensional ordered subsets expectation maximization for regional cerebral blood flow measurement].

Okada M, Hayashi M, Tsuji H, Akagi H, Okayama K, Narumi Y.

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68(5):573-83. Japanese.

3.

Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.

Olsson A, Arlig A, Carlsson GA, Gustafsson A.

Nucl Med Commun. 2007 Sep;28(9):719-25.

PMID:
17667751
4.
5.
6.

New Regression Equation for 123I-IMP Non-invasive Cerebral Blood Flow Measurement Using the Graph Plot Method.

Tomimatsu T, Yamashita K, Ofuji A, Nagaoka R, Miyajima R, Arisako T, Iseri T, Ito S.

Nihon Hoshasen Gijutsu Gakkai Zasshi. 2015 Jul;71(7):612-20. doi: 10.6009/jjrt.2015_JSRT_71.7.612.

7.

The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.

Kalantari F, Rajabi H, Ay MR, Razavi-Ratki SK, Fard-Esfahani A, Beiki D, Eftekhari M, Fallahi B, Sadeghian L, Emami-Ardekani A.

Hell J Nucl Med. 2012 May-Aug;15(2):92-7. doi: 10.1967/s002449910027. Epub 2012 Jun 27.

PMID:
22741145
8.

Effects of tissue heterogeneity on cerebral vascular response to acetazolamide stress measured by an I-123-IMP autoradiographic method with single-photon emission computed tomography.

Ito H, Shidahara M, Inoue K, Goto R, Kinomura S, Taki Y, Okada K, Kaneta T, Sato K, Sato T, Fukuda H.

Ann Nucl Med. 2005 Jun;19(4):251-60.

PMID:
16097633
9.

Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT.

Iida H, Narita Y, Kado H, Kashikura A, Sugawara S, Shoji Y, Kinoshita T, Ogawa T, Eberl S.

J Nucl Med. 1998 Jan;39(1):181-9.

10.

Preliminary evaluation of image reconstruction by ordered-subset expectation maximization in thallium-201 lung scintigraphy.

Bai J, Yokoyama K, Kinuya S, Nakajima K, Yamada M, Ichiyanagi K, Michigishi T, Tonami N.

Ann Nucl Med. 2003 Oct;17(7):619-24.

PMID:
14651366
11.

Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I] p-iodoamphetamine.

Nishizawa S, Iida H, Tsuchida T, Ito H, Konishi J, Yonekura Y.

Eur J Nucl Med Mol Imaging. 2003 Jul;30(7):943-50. Epub 2003 May 7.

PMID:
12734690
12.

Image quality and data quantification in dopamine transporter SPECT: advantage of 3-dimensional OSEM reconstruction?

Winz OH, Hellwig S, Mix M, Weber WA, Mottaghy FM, Schäfer WM, Meyer PT.

Clin Nucl Med. 2012 Sep;37(9):866-71. doi: 10.1097/RLU.0b013e318251e1b3.

PMID:
22889776
13.
14.

Effects of scatter correction on regional distribution of cerebral blood flow using I-123-IMP and SPECT.

Ito H, Iida H, Kinoshita T, Hatazawa J, Okudera T, Uemura K.

Ann Nucl Med. 1999 Oct;13(5):331-6.

PMID:
10582803
15.

Regional differences in distribution volume of I-123 IMP in the human brain: effect on CBF calculated by ARG method.

Inoue K, Ito H, Nakagawa M, Goto R, Yamazaki T, Fukuda H.

Ann Nucl Med. 2002 Jul;16(5):311-6.

PMID:
12230090
16.
18.

Estimation of ¹²³I-IMP arterial blood activity using ¹²³I-IMP acquisition data from the lungs and brain without any blood sampling: validation of its usefulness for quantification of regional cerebral blood flow.

Abe S, Kato K, Takahashi Y, Fujita N, Yamashita M, Shinoda M, Ikeda M, Ohta N, Kajita Y, Naganawa S.

Clin Nucl Med. 2012 Mar;37(3):258-63. doi: 10.1097/RLU.0b013e31823928a7.

PMID:
22310252
19.

Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.

Okuda K, Nakajima K, Yamada M, Wakabayashi H, Ichikawa H, Arai H, Matsuo S, Taki J, Hashimoto M, Kinuya S.

Ann Nucl Med. 2014 Jan;28(1):60-8. doi: 10.1007/s12149-013-0785-6. Epub 2013 Nov 9.

PMID:
24214735
20.

Database of normal human cerebral blood flow measured by SPECT: II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction.

Inoue K, Ito H, Shidahara M, Goto R, Kinomura S, Sato K, Taki Y, Okada K, Kaneta T, Fukuda H.

Ann Nucl Med. 2006 Feb;20(2):139-46.

PMID:
16615423
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk