Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 99

1.

A method for unwrapping highly wrapped multi-echo phase images at very high field: UMPIRE.

Robinson S, Schödl H, Trattnig S.

Magn Reson Med. 2014 Jul;72(1):80-92. doi: 10.1002/mrm.24897. Epub 2013 Jul 30.

2.

Quantitative magnetic susceptibility mapping without phase unwrapping using WASSR.

Lim IA, Li X, Jones CK, Farrell JA, Vikram DS, van Zijl PC.

Neuroimage. 2014 Feb 1;86:265-79. doi: 10.1016/j.neuroimage.2013.09.072. Epub 2013 Oct 8.

3.

Catalytic multiecho phase unwrapping scheme (CAMPUS) in multiecho gradient echo imaging: removing phase wraps on a voxel-by-voxel basis.

Feng W, Neelavalli J, Haacke EM.

Magn Reson Med. 2013 Jul;70(1):117-26. doi: 10.1002/mrm.24457. Epub 2012 Aug 10.

PMID:
22886762
4.

A three-dimensional quality-guided phase unwrapping method for MR elastography.

Wang H, Weaver JB, Perreard II, Doyley MM, Paulsen KD.

Phys Med Biol. 2011 Jul 7;56(13):3935-52. doi: 10.1088/0031-9155/56/13/012. Epub 2011 Jun 10.

5.

High-resolution, large dynamic range field map estimation.

Dagher J, Reese T, Bilgin A.

Magn Reson Med. 2014 Jan;71(1):105-17. doi: 10.1002/mrm.24636. Epub 2013 Feb 11.

6.
7.

Combining phase images from array coils using a short echo time reference scan (COMPOSER).

Robinson SD, Dymerska B, Bogner W, Barth M, Zaric O, Goluch S, Grabner G, Deligianni X, Bieri O, Trattnig S.

Magn Reson Med. 2015 Dec 29. doi: 10.1002/mrm.26093. [Epub ahead of print]

PMID:
26712454
8.

Combining phase images from multi-channel RF coils using 3D phase offset maps derived from a dual-echo scan.

Robinson S, Grabner G, Witoszynskyj S, Trattnig S.

Magn Reson Med. 2011 Jun;65(6):1638-48. doi: 10.1002/mrm.22753. Epub 2011 Jan 19.

PMID:
21254207
9.

Phase-aligned multiple spin-echo averaging: a simple way to improve signal-to-noise ratio of in vivo mouse spinal cord diffusion tensor image.

Tu TW, Budde MD, Xie M, Chen YJ, Wang Q, Quirk JD, Song SK.

Magn Reson Imaging. 2014 Dec;32(10):1335-43. doi: 10.1016/j.mri.2014.07.004. Epub 2014 Aug 1.

10.

A three-point Dixon method for water and fat separation using 2D and 3D gradient-echo techniques.

Wang Y, Li D, Haacke EM, Brown JJ.

J Magn Reson Imaging. 1998 May-Jun;8(3):703-10.

PMID:
9626890
11.

A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation.

Chiou JY, Ahn CB, Muftuler LT, Nalcioglu O.

IEEE Trans Med Imaging. 2003 Feb;22(2):200-5.

PMID:
12715996
12.

Phase unwrapping in the three-point Dixon method for fat suppression MR imaging.

Szumowski J, Coshow WR, Li F, Quinn SF.

Radiology. 1994 Aug;192(2):555-61.

PMID:
8029431
13.

Reliable two-dimensional phase unwrapping method using region growing and local linear estimation.

Zhou K, Zaitsev M, Bao S.

Magn Reson Med. 2009 Oct;62(4):1085-90. doi: 10.1002/mrm.22074.

14.

Artifactual microhemorrhage generated by susceptibility weighted image processing.

Li N, Wang WT, Pham DL, Butman JA.

J Magn Reson Imaging. 2015 Jun;41(6):1695-700. doi: 10.1002/jmri.24728. Epub 2014 Aug 20.

PMID:
25143262
15.

Phase quality map based on local multi-unwrapped results for two-dimensional phase unwrapping.

Zhong H, Tang J, Zhang S.

Appl Opt. 2015 Feb 1;54(4):739-45. doi: 10.1364/AO.54.000739.

PMID:
25967782
16.

Intervention-based multidimensional phase unwrapping using recursive orthogonal referring.

Liu J, Drangova M.

Magn Reson Med. 2012 Oct;68(4):1303-16. doi: 10.1002/mrm.24140. Epub 2012 Jan 9.

PMID:
22231672
17.

Integrated Laplacian-based phase unwrapping and background phase removal for quantitative susceptibility mapping.

Li W, Avram AV, Wu B, Xiao X, Liu C.

NMR Biomed. 2014 Feb;27(2):219-27. doi: 10.1002/nbm.3056. Epub 2013 Dec 11.

18.

B0 mapping with multi-channel RF coils at high field.

Robinson S, Jovicich J.

Magn Reson Med. 2011 Oct;66(4):976-88. doi: 10.1002/mrm.22879. Epub 2011 May 23.

PMID:
21608027
19.

Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm.

Loecher M, Schrauben E, Johnson KM, Wieben O.

J Magn Reson Imaging. 2016 Apr;43(4):833-42. doi: 10.1002/jmri.25045. Epub 2015 Sep 28.

PMID:
26417641
20.

Inter-echo variance as a weighting factor for multi-channel combination in multi-echo acquisition for local frequency shift mapping.

Liu J, Rudko DA, Gati JS, Menon RS, Drangova M.

Magn Reson Med. 2015 Apr;73(4):1654-61. doi: 10.1002/mrm.25247. Epub 2014 Apr 18.

PMID:
24753032
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk