Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 182

Similar articles for PubMed (Select 23796911)

1.

Effect of fatigue loading on the screw joint stability of zirconium abutment.

Tsumita M, Kokubo Y, Kano T, Sasaki K.

J Prosthodont Res. 2013 Jul;57(3):219-23. doi: 10.1016/j.jpor.2013.02.004. Epub 2013 Jun 21.

2.

Analysis of dimensional changes in the screw and the surface topography at the interface of a titanium screw and a zirconia abutment under cyclic loading: an in vitro study.

Dhingra A, Weiner S, Luke AC, Ricci JL.

Int J Oral Maxillofac Implants. 2013 May-Jun;28(3):661-9. doi: 10.11607/jomi.2370.

PMID:
23748295
3.

Fracture resistance of titanium and zirconia abutments: an in vitro study.

Foong JK, Judge RB, Palamara JE, Swain MV.

J Prosthet Dent. 2013 May;109(5):304-12. doi: 10.1016/S0022-3913(13)60306-6.

PMID:
23684280
4.

Load fatigue performance of conical implant-abutment connections.

Seetoh YL, Tan KB, Chua EK, Quek HC, Nicholls JI.

Int J Oral Maxillofac Implants. 2011 Jul-Aug;26(4):797-806.

PMID:
21841990
5.

A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface.

Cavusoglu Y, Akça K, Gürbüz R, Cehreli MC.

Int J Oral Maxillofac Implants. 2014 Mar-Apr;29(2):338-43. doi: 10.11607/jomi.3116.

PMID:
24683559
6.

Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.

Stimmelmayr M, Edelhoff D, Güth JF, Erdelt K, Happe A, Beuer F.

Dent Mater. 2012 Dec;28(12):1215-20. doi: 10.1016/j.dental.2012.08.008. Epub 2012 Sep 27.

PMID:
23021964
7.

Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging.

Mühlemann S, Truninger TC, Stawarczyk B, Hämmerle CH, Sailer I.

Clin Oral Implants Res. 2014 Jan;25(1):74-81. doi: 10.1111/clr.12192. Epub 2013 Jun 4.

PMID:
23735182
8.

Wear at the titanium-zirconia implant-abutment interface: a pilot study.

Klotz MW, Taylor TD, Goldberg AJ.

Int J Oral Maxillofac Implants. 2011 Sep-Oct;26(5):970-5.

PMID:
22010078
9.

Examination of the implant-abutment interface after fatigue testing.

Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA.

J Prosthet Dent. 2001 Mar;85(3):268-75.

PMID:
11264934
10.

Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening.

Gehrke P, Dhom G, Brunner J, Wolf D, Degidi M, Piattelli A.

Quintessence Int. 2006 Jan;37(1):19-26.

PMID:
16429699
11.

The implant-abutment interface of alumina and zirconia abutments.

Yüzügüllü B, Avci M.

Clin Implant Dent Relat Res. 2008 May;10(2):113-21. doi: 10.1111/j.1708-8208.2007.00071.x. Epub 2008 Jan 24.

PMID:
18218054
12.

In vitro fatigue and fracture strength testing of one-piece zirconia implant abutments and zirconia implant abutments connected to titanium cores.

Stimmelmayr M, Sagerer S, Erdelt K, Beuer F.

Int J Oral Maxillofac Implants. 2013 Mar-Apr;28(2):488-93. doi: 10.11607/jomi.2772.

PMID:
23527351
13.

Bending moments of zirconia and titanium abutments with internal and external implant-abutment connections after aging and chewing simulation.

Truninger TC, Stawarczyk B, Leutert CR, Sailer TR, Hämmerle CH, Sailer I.

Clin Oral Implants Res. 2012 Jan;23(1):12-8. doi: 10.1111/j.1600-0501.2010.02141.x. Epub 2011 Mar 28.

PMID:
21443610
14.

Load fatigue performance of implant-ceramic abutment combinations.

Nguyen HQ, Tan KB, Nicholls JI.

Int J Oral Maxillofac Implants. 2009 Jul-Aug;24(4):636-46.

PMID:
19885403
15.

In vitro assessment of three types of zirconia implant abutments under static load.

Kim JS, Raigrodski AJ, Flinn BD, Rubenstein JE, Chung KH, Mancl LA.

J Prosthet Dent. 2013 Apr;109(4):255-63. doi: 10.1016/S0022-3913(13)60054-2.

PMID:
23566607
16.

In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections.

Sailer I, Sailer T, Stawarczyk B, Jung RE, Hämmerle CH.

Int J Oral Maxillofac Implants. 2009 Sep-Oct;24(5):850-8.

PMID:
19865625
17.

An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection.

Vigolo P, Fonzi F, Majzoub Z, Cordioli G.

Int J Oral Maxillofac Implants. 2006 Jul-Aug;21(4):575-80.

PMID:
16955608
18.

Bending moments and types of failure of zirconia and titanium abutments with internal implant-abutment connections: a laboratory study.

Leutert CR, Stawarczyk B, Truninger TC, Hämmerle CH, Sailer I.

Int J Oral Maxillofac Implants. 2012 May-Jun;27(3):505-12.

PMID:
22616042
19.

Influence of three types of abutments on preload values before and after cyclic loading with structural analysis by scanning electron microscopy.

Butignon LE, Basilio Mde A, Pereira Rde P, Arioli Filho JN.

Int J Oral Maxillofac Implants. 2013 May-Jun;28(3):e161-70. doi: 10.11607/jomi.2481.

PMID:
23748335
20.
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk