Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 101

Similar articles for PubMed (Select 23700244)

1.

A missing leaflet: a rare cause of structural deterioration of a bovine pericardial aortic bioprosthesis-report of a case.

Nakamura Y, Fujiwara Y, Shiraya S, Saiki M, Harada S, Kishimoto Y, Onohara T, Otsuki Y, Nishimura M.

Surg Today. 2014 Sep;44(9):1757-9. doi: 10.1007/s00595-013-0623-4. Epub 2013 May 23.

PMID:
23700244
2.

Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.

Murakami T, Eishi K, Nakano S, Kobayashi J, Sasako Y, Isobe F, Kosakai Y, Kito Y, Kawashima Y.

J Heart Valve Dis. 1996 Jan;5(1):45-9.

PMID:
8834725
3.

Prognosis after aortic valve replacement with the Carpentier-Edwards pericardial valve: use of microsimulation.

Puvimanasinghe JP, Takkenberg JJ, Eijkemans MJ, Steyerberg EW, van Herwerden LA, Grunkemeier GL, Habbema JD, Bogers AJ.

Ann Thorac Surg. 2005 Sep;80(3):825-31. Review.

PMID:
16122436
4.

Carpentier-Edwards standard porcine bioprosthesis: clinical performance to seventeen years.

Jamieson WR, Munro AI, Miyagishima RT, Allen P, Burr LH, Tyers GF.

Ann Thorac Surg. 1995 Oct;60(4):999-1006; discussion 1007.

PMID:
7575007
5.

Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients.

McClure RS, Narayanasamy N, Wiegerinck E, Lipsitz S, Maloney A, Byrne JG, Aranki SF, Couper GS, Cohn LH.

Ann Thorac Surg. 2010 May;89(5):1410-6. doi: 10.1016/j.athoracsur.2010.01.046.

PMID:
20417753
6.

[Long-term evaluation of the Carpentier-Edwards pericardial bioprosthesis].

Takahara Y, Sudou Y, Murayama H, Nakamura T.

Nihon Kyobu Geka Gakkai Zasshi. 1995 Aug;43(8):1097-102. Japanese.

PMID:
7594841
7.

Accelerated degeneration of a bovine pericardial bioprosthetic aortic valve in children and young adults.

Saleeb SF, Newburger JW, Geva T, Baird CW, Gauvreau K, Padera RF, Del Nido PJ, Borisuk MJ, Sanders SP, Mayer JE.

Circulation. 2014 Jul 1;130(1):51-60. doi: 10.1161/CIRCULATIONAHA.114.009835. Epub 2014 Apr 22.

PMID:
24756063
8.

Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses.

Eric Jamieson WR, Marchand MA, Pelletier CL, Norton R, Pellerin M, Dubiel TW, Aupart MR, Daenen WJ, Holden MP, David TE, Ryba EA, Anderson WN Jr.

J Thorac Cardiovasc Surg. 1999 Aug;118(2):297-304.

PMID:
10425003
9.

Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.

Wagner IM, Eichinger WB, Bleiziffer S, Botzenhardt F, Gebauer I, Guenzinger R, Bauernschmitt R, Lange R.

J Thorac Cardiovasc Surg. 2007 May;133(5):1234-41.

PMID:
17467435
10.

Aortic bioprosthetic valve deterioration 8 months after implantation.

Wiedemann D, Bonaros N, Laufer G, Kocher A.

Ann Thorac Surg. 2010 Jan;89(1):277-9. doi: 10.1016/j.athoracsur.2009.06.081.

PMID:
20103255
11.

Porcine versus pericardial bioprostheses: eleven-year follow up of a prospective randomized trial.

Chaudhry MA, Raco L, Muriithi EW, Bernacca GM, Tolland MM, Wheatley DJ.

J Heart Valve Dis. 2000 May;9(3):429-37; discussion 437-8.

PMID:
10888102
12.

Comparison of reoperation findings of the Carpentier-Edwards (standard) bioprosthesis and the St Jude bioimplant (formerly Liotta) in the mitral position.

Yamak B, Ozsöyler, Ulus AT, Kiziltepe U, Katircioğlu SF, Taşdemir O.

Cardiovasc Surg. 1999 Dec;7(7):730-4.

PMID:
10639048
13.

Carpentier-Edwards pericardial bioprosthesis in aortic or mitral position: a 12-year experience.

Neville PH, Aupart MR, Diemont FF, Sirinelli AL, Lemoine EM, Marchand MA.

Ann Thorac Surg. 1998 Dec;66(6 Suppl):S143-7.

PMID:
9930436
14.

Mid-term comparative follow-up after aortic valve replacement with Carpentier-Edwards and Pericarbon pericardial prostheses.

Le Tourneau T, Savoye C, McFadden EP, Grandmougin D, Carton HF, Hennequin JL, Dubar A, Fayad G, Warembourg H.

Circulation. 1999 Nov 9;100(19 Suppl):II11-6.

15.

Late hemodynamic and clinical outcomes of aortic valve replacement with the Carpentier-Edwards Perimount pericardial bioprosthesis.

Dellgren G, David TE, Raanani E, Armstrong S, Ivanov J, Rakowski H.

J Thorac Cardiovasc Surg. 2002 Jul;124(1):146-54.

PMID:
12091820
16.

The perimount valve in the aortic position: twenty-year experience with patients under 60 years old.

Forcillo J, El Hamamsy I, Stevens LM, Badrudin D, Pellerin M, Perrault LP, Cartier R, Bouchard D, Carrier M, Demers P.

Ann Thorac Surg. 2014 May;97(5):1526-32. doi: 10.1016/j.athoracsur.2014.02.019. Epub 2014 Mar 28.

PMID:
24681031
17.

Carpentier-Edwards porcine bioprostheses: clinical performance assessed by actual analysis.

Jamieson WR, Miyagishima RT, Burr LH, Lichtenstein SV, Fradet GJ, Janusz MT.

J Heart Valve Dis. 2000 Jul;9(4):530-5.

PMID:
10947046
18.

Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural valve deterioration) by age groups.

Jamieson WR, Rosado LJ, Munro AI, Gerein AN, Burr LH, Miyagishima RT, Janusz MT, Tyers GF.

Ann Thorac Surg. 1988 Aug;46(2):155-62.

PMID:
3401075
19.

Comparison of Carpentier-Edwards pericardial and supraannular bioprostheses in aortic valve replacement.

Puvimanasinghe JP, Takkenberg JJ, Eijkemans MJ, van Herwerden LA, Jamieson WR, Grunkemeier GL, Habbema JD, Bogers AJ.

Eur J Cardiothorac Surg. 2006 Mar;29(3):374-9. Epub 2006 Jan 18. Review.

PMID:
16386920
20.

Ten-year echocardiographic and clinical follow-up of aortic Carpentier-Edwards pericardial and supraannular prosthesis: a case-match study.

Le Tourneau T, Vincentelli A, Fayad G, Savoye C, Fabre OH, Prat A, Warembourg H.

Ann Thorac Surg. 2002 Dec;74(6):2010-5.

PMID:
12643388
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk