Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 113

1.

[Transcatheter closure of patent ductus arteriosus with the new Amplatzer Duct OccluderII].

Ji W, Li F, Gao W, Yu ZQ, Huang MR, Fu LJ, Guo Y, Zhao PJ, Liu TL, Zhang YQ, Chen YW.

Zhonghua Er Ke Za Zhi. 2013 Feb;51(2):126-9. Chinese.

PMID:
23527979
2.

Percutaneous closure of a moderate to large tubular or elongated patent ductus arteriosus in children younger than 3 years: is the ADO II appropriate?

Kumar SM, Subramanian V, Bijulal S, Krishnamoorthy KM, Sivasankaran S, Tharakan JA.

Pediatr Cardiol. 2013 Oct;34(7):1661-7. doi: 10.1007/s00246-013-0700-x. Epub 2013 Apr 17.

PMID:
23591801
3.

Long-term clinical experience with Amplatzer Ductal Occluder II for closure of the persistent arterial duct in children.

Kang SL, Morgan G, Forsey J, Tometzki A, Martin R.

Catheter Cardiovasc Interv. 2014 Jun 1;83(7):1102-8. doi: 10.1002/ccd.25393. Epub 2014 Jan 31.

PMID:
24403100
4.

Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices.

Liddy S, Oslizlok P, Walsh KP.

Catheter Cardiovasc Interv. 2013 Aug 1;82(2):253-9. doi: 10.1002/ccd.24768. Epub 2013 Feb 21.

PMID:
23427043
5.

Closure of the patent ductus arteriosus with the new duct occluder II additional sizes device.

Agnoletti G, Marini D, Villar AM, Bordese R, Gabbarini F.

Catheter Cardiovasc Interv. 2012 Jun 1;79(7):1169-74. doi: 10.1002/ccd.23477. Epub 2012 Mar 15.

PMID:
22422478
6.

Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta.

Masri S, El Rassi I, Arabi M, Tabbakh A, Bitar F.

Catheter Cardiovasc Interv. 2015 Aug;86(2):E66-72. doi: 10.1002/ccd.25940. Epub 2015 May 29.

PMID:
26032159
7.

Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.

Karagöz T, Akin A, Ertuğrul I, Aykan HH, Alehan D, Ozer S, Ozkutlu S.

Acta Cardiol. 2012 Dec;67(6):675-80.

8.

[Percutaneous closure of patent ductus arteriosus: short term results].

Kaya Y, Bulut MO, Yurtdaş M, Karakurt A, Güvenç TS, Söylemez N, Güler A, Gönüllü E, Ceylan Y, Akdemir R.

Turk Kardiyol Dern Ars. 2013 Jun;41(4):310-8. doi: 10.5543/tkda.2013.72693. Turkish.

9.

Transthoracic echocardiography as an alternative major guidance to angiography during transcatheter closure of patent ductus arteriosus: technical feasibility and clinical relevance.

Chen W, Yan X, Huang Y, Sun X, Zhong L, Li J, Chen H, Zhong H, Chen L.

Pediatr Cardiol. 2015 Jan;36(1):14-9. doi: 10.1007/s00246-014-0956-9. Epub 2014 Jul 29.

PMID:
25070385
10.

Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study.

Sungur M, Karakurt C, Ozbarlas N, Baspinar O.

Catheter Cardiovasc Interv. 2013 Aug 1;82(2):245-52. doi: 10.1002/ccd.24905. Epub 2013 Apr 8.

PMID:
23460349
11.

Trans-catheter closure of patent ductus arteriosus-What is the best device?

Ghasemi A, Pandya S, Reddy SV, Turner DR, Du W, Navabi MA, Mirzaaghayan MR, Kiani A, Sloan K, Forbes TJ.

Catheter Cardiovasc Interv. 2010 Nov 1;76(5):687-95. doi: 10.1002/ccd.22393.

PMID:
20815044
12.

Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

Wang JK, Wu MH, Lin MT, Chiu SN, Chen CA, Chiu HH.

Circ J. 2010 Feb;74(2):361-4. Epub 2009 Dec 22.

13.

Transcatheter occlusion of the patent ductus arteriosus in infants: experimental testing of a new Amplatzer device.

Bass JL, Wilson N.

Catheter Cardiovasc Interv. 2014 Feb;83(2):250-5. doi: 10.1002/ccd.22931. Epub 2013 Oct 23.

PMID:
24446324
14.

Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder.

Thanopoulos BD, Hakim FA, Hiari A, Goussous Y, Basta E, Zarayelyan AA, Tsaousis GS.

J Am Coll Cardiol. 2000 Mar 15;35(4):1016-21.

15.

Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.

Celebi A, Demir IH, Saritaş T, Dedeoğlu R, Yucel IK, Demir F, Erdem A.

Catheter Cardiovasc Interv. 2013 Nov 15;82(6):961-7. doi: 10.1002/ccd.24957. Epub 2013 Aug 9.

PMID:
23592558
16.

The Amplatzer Duct Occluder II Additional Sizes device for transcatheter PDA closure: initial experience.

Bruckheimer E, Godfrey M, Dagan T, Levinzon M, Amir G, Birk E.

Catheter Cardiovasc Interv. 2014 Jun 1;83(7):1097-101. doi: 10.1002/ccd.25445. Epub 2014 Mar 4.

PMID:
24532416
17.

[A follow-up study on transcatheter closure of patent ductus arteriosus with Amplatzer duct occluder in children].

Li JJ, Li YF, Zhang ZW, Qian MY, Wang HS.

Zhonghua Er Ke Za Zhi. 2005 Aug;43(8):608-11. Chinese.

PMID:
16191275
18.

Clinical evaluation of the new Amplatzer duct occluder II for patent arterial duct occlusion.

Bhole V, Miller P, Mehta C, Stumper O, Reinhardt Z, De Giovanni JV.

Catheter Cardiovasc Interv. 2009 Nov 1;74(5):762-9. doi: 10.1002/ccd.22095.

PMID:
19522000
19.

A Retrospective Study of 1,526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus.

Jin M, Liang YM, Wang XF, Guo BJ, Zheng K, Gu Y, Lyu ZY.

Chin Med J (Engl). 2015 Sep 5;128(17):2284-9. doi: 10.4103/0366-6999.163398.

20.

Comparison of transvenous versus transthoracic catheter-based device closure of patent ductus arteriosus with amplatzer duct occluder.

Chen LY, Cai P, Cheng ZD, Zhang ZB, Chen DZ, Cao H, Qiu HF, Chen LL.

J Invasive Cardiol. 2013 Oct;25(10):502-6.

Items per page

Supplemental Content

Write to the Help Desk