Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 112

Similar articles for PubMed (Select 23524319)

1.

Predictive value of impedance changes for real-time contact force measurements during catheter ablation of atrial arrhythmias in humans.

Kumar S, Haqqani HM, Chan M, Lee J, Yudi M, Wong MC, Morton JB, Ling LH, Robinson T, Heck PM, Kelland NF, Halloran K, Spence SJ, Kistler PM, Kalman JM.

Heart Rhythm. 2013 Jul;10(7):962-9. doi: 10.1016/j.hrthm.2013.03.022. Epub 2013 Mar 22.

PMID:
23524319
2.

Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans.

Kumar S, Chan M, Lee J, Wong MC, Yudi M, Morton JB, Spence SJ, Halloran K, Kistler PM, Kalman JM.

J Cardiovasc Electrophysiol. 2014 Feb;25(2):122-9. doi: 10.1111/jce.12293. Epub 2013 Oct 11.

PMID:
24102727
3.

In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation.

Makimoto H, Lin T, Rillig A, Metzner A, Wohlmuth P, Arya A, Antz M, Mathew S, Deiss S, Wissner E, Rausch P, Bardyszewski A, Kamioka M, Li X, Kuck KH, Ouyang F, Tilz RR.

Circ Arrhythm Electrophysiol. 2014 Feb;7(1):46-54. doi: 10.1161/CIRCEP.113.000556. Epub 2013 Dec 20.

4.

Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation.

Nakagawa H, Kautzner J, Natale A, Peichl P, Cihak R, Wichterle D, Ikeda A, Santangeli P, Di Biase L, Jackman WM.

Circ Arrhythm Electrophysiol. 2013 Aug;6(4):746-53. doi: 10.1161/CIRCEP.113.978320. Epub 2013 Jul 19.

5.

Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.

Reichlin T, Knecht S, Lane C, Kühne M, Nof E, Chopra N, Tadros TM, Reddy VY, Schaer B, John RM, Osswald S, Stevenson WG, Sticherling C, Michaud GF.

Heart Rhythm. 2014 Feb;11(2):194-201. doi: 10.1016/j.hrthm.2013.10.048. Epub 2013 Oct 28.

PMID:
24177370
6.

Contact force and force-time integral in atrial radiofrequency ablation predict transmurality of lesions.

Squara F, Latcu DG, Massaad Y, Mahjoub M, Bun SS, Saoudi N.

Europace. 2014 May;16(5):660-7. doi: 10.1093/europace/euu068.

PMID:
24798957
7.

Ablation effect indicated by impedance fall is correlated with contact force level during ablation for atrial fibrillation.

De Bortoli A, Sun LZ, Solheim E, Hoff PI, Schuster P, Ohm OJ, Chen J.

J Cardiovasc Electrophysiol. 2013 Nov;24(11):1210-5. doi: 10.1111/jce.12215. Epub 2013 Jul 19.

PMID:
23865557
8.

A novel radiofrequency ablation catheter using contact force sensing: Toccata study.

Kuck KH, Reddy VY, Schmidt B, Natale A, Neuzil P, Saoudi N, Kautzner J, Herrera C, Hindricks G, Jaïs P, Nakagawa H, Lambert H, Shah DC.

Heart Rhythm. 2012 Jan;9(1):18-23. doi: 10.1016/j.hrthm.2011.08.021. Epub 2011 Aug 26.

PMID:
21872560
9.

Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.

Ullah W, Hunter RJ, Baker V, Dhinoja MB, Sporton S, Earley MJ, Schilling RJ.

Circ Arrhythm Electrophysiol. 2014 Feb;7(1):63-8. doi: 10.1161/CIRCEP.113.001137. Epub 2014 Jan 18.

10.

The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Reddy VY, Shah D, Kautzner J, Schmidt B, Saoudi N, Herrera C, Jaïs P, Hindricks G, Peichl P, Yulzari A, Lambert H, Neuzil P, Natale A, Kuck KH.

Heart Rhythm. 2012 Nov;9(11):1789-95. doi: 10.1016/j.hrthm.2012.07.016. Epub 2012 Jul 20.

PMID:
22820056
11.

Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size.

Ikeda A, Nakagawa H, Lambert H, Shah DC, Fonck E, Yulzari A, Sharma T, Pitha JV, Lazzara R, Jackman WM.

Circ Arrhythm Electrophysiol. 2014 Dec;7(6):1174-80. doi: 10.1161/CIRCEP.113.001094. Epub 2014 Nov 7.

PMID:
25381331
12.

Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias.

Kumar S, Morton JB, Halloran K, Spence SJ, Lee G, Wong MC, Kistler PM, Kalman JM.

Heart Rhythm. 2012 Jul;9(7):1041-1047.e1. doi: 10.1016/j.hrthm.2012.02.015. Epub 2012 Feb 14.

PMID:
22342855
13.

Different patterns of the fall of impedance as the result of heating during ostial pulmonary vein ablation: implications for power titration.

Reithmann C, Remp T, Hoffmann E, Matis T, Wakili R, Steinbeck G.

Pacing Clin Electrophysiol. 2005 Dec;28(12):1282-91.

PMID:
16403160
14.

Contact force-controlled zero-fluoroscopy catheter ablation of right-sided and left atrial arrhythmia substrates.

Kerst G, Weig HJ, Weretka S, Seizer P, Hofbeck M, Gawaz M, Schreieck J.

Heart Rhythm. 2012 May;9(5):709-14. doi: 10.1016/j.hrthm.2011.12.025. Epub 2012 Jan 2.

PMID:
22222276
15.

Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.

Yokoyama K, Nakagawa H, Shah DC, Lambert H, Leo G, Aeby N, Ikeda A, Pitha JV, Sharma T, Lazzara R, Jackman WM.

Circ Arrhythm Electrophysiol. 2008 Dec;1(5):354-62. doi: 10.1161/CIRCEP.108.803650. Epub 2008 Dec 2.

16.

Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.

Neuzil P, Reddy VY, Kautzner J, Petru J, Wichterle D, Shah D, Lambert H, Yulzari A, Wissner E, Kuck KH.

Circ Arrhythm Electrophysiol. 2013 Apr;6(2):327-33. doi: 10.1161/CIRCEP.113.000374. Epub 2013 Mar 20.

17.

Low-power radiofrequency application and intracardiac echocardiography for creation of continuous left atrial linear lesions.

Roithinger FX, Steiner PR, Goseki Y, Liese KS, Scholtz DB, Sippensgroenewegen A, Ursell P, Lesh MD.

J Cardiovasc Electrophysiol. 1999 May;10(5):680-91.

PMID:
10355924
18.

Simultaneous assessment of contact pressure and local electrical coupling index using robotic navigation.

Dello Russo A, Fassini G, Casella M, Bologna F, Al-Nono O, Colombo D, Biagioli V, Santangeli P, Di Biase L, Zucchetti M, Majocchi B, Marino V, Gallinghouse JJ, Natale A, Tondo C.

J Interv Card Electrophysiol. 2014 Jun;40(1):23-31. doi: 10.1007/s10840-014-9882-2. Epub 2014 Mar 16.

PMID:
24633546
19.

Endocardial impedance mapping during circumferential pulmonary vein ablation of atrial fibrillation differentiates between atrial and venous tissue.

Lang CC, Gugliotta F, Santinelli V, Mesas C, Tomita T, Vicedomini G, Augello G, Gulletta S, Mazzone P, De Cobelli F, Del Maschio A, Pappone C.

Heart Rhythm. 2006 Feb;3(2):171-8.

PMID:
16443532
20.

Radiofrequency catheter ablation of common atrial flutter in 200 patients.

Fischer B, Jaïs P, Shah D, Chouairi S, Haïssaguerre M, Garrigues S, Poquet F, Gencel L, Clémenty J, Marcus FI.

J Cardiovasc Electrophysiol. 1996 Dec;7(12):1225-33.

PMID:
8985812
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk