Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 309

1.

Acoustic radiation force impulse imaging for non-invasive assessment of liver fibrosis in chronic hepatitis B.

Friedrich-Rust M, Buggisch P, de Knegt RJ, Dries V, Shi Y, Matschenz K, Schneider MD, Herrmann E, Petersen J, Schulze F, Zeuzem S, Sarrazin C.

J Viral Hepat. 2013 Apr;20(4):240-7. doi: 10.1111/j.1365-2893.2012.01646.x. Epub 2012 Jul 31.

PMID:
23490368
[PubMed - indexed for MEDLINE]
2.

Comparison of acoustic radiation force impulse imaging (ARFI) to liver biopsy histologic scores in the evaluation of chronic liver disease: A pilot study.

Haque M, Robinson C, Owen D, Yoshida EM, Harris A.

Ann Hepatol. 2010 Jul-Sep;9(3):289-93.

PMID:
20720270
[PubMed - indexed for MEDLINE]
3.

Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastography.

Friedrich-Rust M, Wunder K, Kriener S, Sotoudeh F, Richter S, Bojunga J, Herrmann E, Poynard T, Dietrich CF, Vermehren J, Zeuzem S, Sarrazin C.

Radiology. 2009 Aug;252(2):595-604. doi: 10.1148/radiol.2523081928.

PMID:
19703889
[PubMed - indexed for MEDLINE]
4.

Measurement of liver elasticity with acoustic radiation force impulse (ARFI) technology: an alternative noninvasive method for staging liver fibrosis in viral hepatitis.

Goertz RS, Zopf Y, Jugl V, Heide R, Janson C, Strobel D, Bernatik T, Haendl T.

Ultraschall Med. 2010 Apr;31(2):151-5. doi: 10.1055/s-0029-1245244. Epub 2010 Mar 19.

PMID:
20306380
[PubMed - indexed for MEDLINE]
5.

Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®).

Ebinuma H, Saito H, Komuta M, Ojiro K, Wakabayashi K, Usui S, Chu PS, Umeda R, Ishibashi Y, Takayama T, Kikuchi M, Nakamoto N, Yamagishi Y, Kanai T, Ohkuma K, Sakamoto M, Hibi T.

J Gastroenterol. 2011 Oct;46(10):1238-48. doi: 10.1007/s00535-011-0437-3. Epub 2011 Jul 21.

PMID:
21779759
[PubMed - indexed for MEDLINE]
6.

Liver fibrosis: noninvasive assessment with acoustic radiation force impulse elastography--comparison with FibroScan M and XL probes and FibroTest in patients with chronic liver disease.

Cassinotto C, Lapuyade B, Aït-Ali A, Vergniol J, Gaye D, Foucher J, Bailacq-Auder C, Chermak F, Le Bail B, de Lédinghen V.

Radiology. 2013 Oct;269(1):283-92. doi: 10.1148/radiol.13122208. Epub 2013 Apr 29.

PMID:
23630312
[PubMed - indexed for MEDLINE]
7.

Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C.

Rizzo L, Calvaruso V, Cacopardo B, Alessi N, Attanasio M, Petta S, Fatuzzo F, Montineri A, Mazzola A, L'abbate L, Nunnari G, Bronte F, Di Marco V, Craxì A, Cammà C.

Am J Gastroenterol. 2011 Dec;106(12):2112-20. doi: 10.1038/ajg.2011.341. Epub 2011 Oct 4.

PMID:
21971536
[PubMed - indexed for MEDLINE]
8.

Comparative study concerning the value of acoustic radiation force impulse elastography (ARFI) in comparison with transient elastography (TE) for the assessment of liver fibrosis in patients with chronic hepatitis B and C.

Sporea I, Sirli R, Bota S, Popescu A, Sendroiu M, Jurchis A.

Ultrasound Med Biol. 2012 Aug;38(8):1310-6. doi: 10.1016/j.ultrasmedbio.2012.03.011. Epub 2012 Jun 12.

PMID:
22698510
[PubMed - indexed for MEDLINE]
9.

Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD.

Friedrich-Rust M, Romen D, Vermehren J, Kriener S, Sadet D, Herrmann E, Zeuzem S, Bojunga J.

Eur J Radiol. 2012 Mar;81(3):e325-31. doi: 10.1016/j.ejrad.2011.10.029. Epub 2011 Nov 26.

PMID:
22119555
[PubMed - indexed for MEDLINE]
10.

Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study.

Takahashi H, Ono N, Eguchi Y, Eguchi T, Kitajima Y, Kawaguchi Y, Nakashita S, Ozaki I, Mizuta T, Toda S, Kudo S, Miyoshi A, Miyazaki K, Fujimoto K.

Liver Int. 2010 Apr;30(4):538-45. doi: 10.1111/j.1478-3231.2009.02130.x. Epub 2009 Oct 27.

PMID:
19874490
[PubMed - indexed for MEDLINE]
11.

Acoustic Radiation Force Impulse elastography for fibrosis evaluation in patients with chronic hepatitis C: an international multicenter study.

Sporea I, Bota S, Peck-Radosavljevic M, Sirli R, Tanaka H, Iijima H, Badea R, Lupsor M, Fierbinteanu-Braticevici C, Petrisor A, Saito H, Ebinuma H, Friedrich-Rust M, Sarrazin C, Takahashi H, Ono N, Piscaglia F, Borghi A, D'Onofrio M, Gallotti A, Ferlitsch A, Popescu A, Danila M.

Eur J Radiol. 2012 Dec;81(12):4112-8. doi: 10.1016/j.ejrad.2012.08.018. Epub 2012 Sep 20.

PMID:
23000186
[PubMed - indexed for MEDLINE]
12.

Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis.

Friedrich-Rust M, Nierhoff J, Lupsor M, Sporea I, Fierbinteanu-Braticevici C, Strobel D, Takahashi H, Yoneda M, Suda T, Zeuzem S, Herrmann E.

J Viral Hepat. 2012 Feb;19(2):e212-9. doi: 10.1111/j.1365-2893.2011.01537.x. Epub 2011 Oct 30.

PMID:
22239521
[PubMed - indexed for MEDLINE]
13.

The usefulness of transient elastography, acoustic-radiation-force impulse elastography, and real-time elastography for the evaluation of liver fibrosis.

Chung JH, Ahn HS, Kim SG, Lee YN, Kim YS, Jeong SW, Jang JY, Lee SH, Kim HS, Kim BS.

Clin Mol Hepatol. 2013 Jun;19(2):156-64. doi: 10.3350/cmh.2013.19.2.156. Epub 2013 Jun 27.

PMID:
23837140
[PubMed - indexed for MEDLINE]
Free PMC Article
14.

Evaluation of acoustic radiation force impulse imaging for determination of liver stiffness using transient elastography as a reference.

Kircheis G, Sagir A, Vogt C, Vom Dahl S, Kubitz R, Häussinger D.

World J Gastroenterol. 2012 Mar 14;18(10):1077-84. doi: 10.3748/wjg.v18.i10.1077.

PMID:
22416182
[PubMed - indexed for MEDLINE]
Free PMC Article
15.

Head-to-head comparison of transient elastography (TE), real-time tissue elastography (RTE), and acoustic radiation force impulse (ARFI) imaging in the diagnosis of liver fibrosis.

Colombo S, Buonocore M, Del Poggio A, Jamoletti C, Elia S, Mattiello M, Zabbialini D, Del Poggio P.

J Gastroenterol. 2012 Apr;47(4):461-9. doi: 10.1007/s00535-011-0509-4. Epub 2012 Jan 6.

PMID:
22223175
[PubMed - indexed for MEDLINE]
16.

Liver and spleen stiffness measured by acoustic radiation force impulse elastography for noninvasive assessment of liver fibrosis and esophageal varices in patients with chronic hepatitis B.

Ye XP, Ran HT, Cheng J, Zhu YF, Zhang DZ, Zhang P, Zheng YY.

J Ultrasound Med. 2012 Aug;31(8):1245-53.

PMID:
22837289
[PubMed - indexed for MEDLINE]
Free Article
17.

Acoustic radiation force impulse imaging (ARFI) for non-invasive detection of liver fibrosis: examination standards and evaluation of interlobe differences in healthy subjects and chronic liver disease.

Karlas T, Pfrepper C, Wiegand J, Wittekind C, Neuschulz M, Mössner J, Berg T, Tröltzsch M, Keim V.

Scand J Gastroenterol. 2011 Dec;46(12):1458-67. doi: 10.3109/00365521.2011.610004. Epub 2011 Sep 15.

PMID:
21916815
[PubMed - indexed for MEDLINE]
18.

Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies.

Sporea I, Sirli RL, Deleanu A, Popescu A, Focsa M, Danila M, Tudora A.

Ultraschall Med. 2011 Jan;32 Suppl 1:S46-52. doi: 10.1055/s-0029-1245360. Epub 2010 Jul 5.

PMID:
20603783
[PubMed - indexed for MEDLINE]
19.

Liver stiffness measurement using acoustic radiation force impulse (ARFI) elastography and effect of necroinflammation.

Yoon KT, Lim SM, Park JY, Kim do Y, Ahn SH, Han KH, Chon CY, Cho M, Lee JW, Kim SU.

Dig Dis Sci. 2012 Jun;57(6):1682-91. doi: 10.1007/s10620-012-2044-4.

PMID:
22302243
[PubMed - indexed for MEDLINE]
20.

Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis.

Fierbinteanu-Braticevici C, Andronescu D, Usvat R, Cretoiu D, Baicus C, Marinoschi G.

World J Gastroenterol. 2009 Nov 28;15(44):5525-32.

PMID:
19938190
[PubMed - indexed for MEDLINE]
Free PMC Article

Display Settings:

Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk