Format
Items per page
Sort by

Send to:

Choose Destination

Results: 1 to 20 of 102

Related Citations for PubMed (Select 23354830)

1.

Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

Qian LX, Hao DJ, He BR, Jiang YH.

Eur Spine J. 2013 May;22(5):1142-6. doi: 10.1007/s00586-013-2662-3. Epub 2013 Jan 29.

2.

Is the 4 mm height of the vertebral artery groove really a limitation of C1 pedicle screw insertion?

Huang DG, He SM, Pan JW, Hui H, Hu HM, He BR, Li H, Zhang XF, Hao DJ.

Eur Spine J. 2014 May;23(5):1109-14. doi: 10.1007/s00586-014-3217-y. Epub 2014 Feb 9.

PMID:
24509775
3.

[Classification of atlas pedicles and methodological study of pedicle screw fixation].

He F, Yin Q, Zhao T.

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008 Aug;22(8):905-9. Chinese.

PMID:
18773802
4.

Computed tomography-based morphometric analysis of cervical pedicles in Indian population: a pilot study to assess feasibility of transpedicular screw fixation.

Patwardhan AR, Nemade PS, Bhosale SK, Srivastava SK.

J Postgrad Med. 2012 Apr-Jun;58(2):119-22. doi: 10.4103/0022-3859.97173.

5.

C2 pedicle screw and plate combined with C1 titanium cable fixation for the treatment of atlantoaxial instability not suitable for placement of C1 screw.

Xiao ZM, Zhan XL, Gong de F, Chen QF, Luo GB, Jiang H.

J Spinal Disord Tech. 2008 Oct;21(7):514-7. doi: 10.1097/BSD.0b013e31815c5fba.

PMID:
18836364
6.

Posterior fixation and fusion with atlas pedicle screw system for upper cervical diseases.

Li L, Zhou FH, Wang H, Cui SQ.

Chin J Traumatol. 2008 Dec;11(6):323-8.

PMID:
19032845
7.

Cable-strengthened C2 pedicle screw fixation in the treatment of congenital C2-3 fusion, atlas occipitalization, and atlantoaxial dislocation.

Wang S, Wang C, Leng H, Zhao W, Yan M, Zhou H.

Neurosurgery. 2012 Nov;71(5):976-84; discussion 984. doi: 10.1227/NEU.0b013e31826cdd3b.

PMID:
22895405
8.

Inter- and intraobserver reliability assessment of computed tomographic 3D measurement of pedicles in scoliosis and size matching with pedicle screws.

Gstoettner M, Lechner R, Glodny B, Thaler M, Bach CM.

Eur Spine J. 2011 Oct;20(10):1771-9. doi: 10.1007/s00586-011-1908-1. Epub 2011 Jul 19.

9.

Anatomical feasibility of C-2 pedicle screw fixation: the effect of variable angle interpolation of axial CT scans.

Burke LM, Yu WD, Ho A, Wagner T, O'Brien JR.

J Neurosurg Spine. 2013 Jun;18(6):564-7. doi: 10.3171/2013.2.SPINE12798. Epub 2013 Mar 29.

PMID:
23540733
10.

Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data.

Reinhold M, Magerl F, Rieger M, Blauth M.

Eur Spine J. 2007 Jan;16(1):47-56. Epub 2006 Apr 21.

11.

Anatomic considerations for the pedicle screw placement in the first cervical vertebra.

Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Zhong SZ.

Spine (Phila Pa 1976). 2005 Jul 1;30(13):1519-23.

PMID:
15990666
12.

Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass.

Tan M, Wang H, Wang Y, Zhang G, Yi P, Li Z, Wei H, Yang F.

Spine (Phila Pa 1976). 2003 May 1;28(9):888-95.

PMID:
12942004
13.

[Clinical application and personal X-ray film and CT design of screw-plate system by pedicle of atlanto-axis manipulatively].

Jia W, Bai G, Yang B, Zheng T, Xu Y, Yun D, Sun H.

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008 Apr;22(4):416-20. Chinese.

PMID:
18575440
14.
15.

Risk of vertebral artery injury: comparison between C1-C2 transarticular and C2 pedicle screws.

Yeom JS, Buchowski JM, Kim HJ, Chang BS, Lee CK, Riew KD.

Spine J. 2013 Jul;13(7):775-85. doi: 10.1016/j.spinee.2013.04.005. Epub 2013 May 14.

PMID:
23684237
16.

Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques.

Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ.

Spine (Phila Pa 1976). 2000 Jul 1;25(13):1655-67.

PMID:
10870141
17.

Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.

Beck M, Mittlmeier T, Gierer P, Harms C, Gradl G.

Eur Spine J. 2009 Oct;18(10):1469-77. doi: 10.1007/s00586-009-1050-5. Epub 2009 Jun 10.

18.

Thoracic pedicle morphometry in different body height population: a three-dimensional study using reformatted computed tomography.

Zhuang Z, Chen Y, Han H, Cai S, Wang X, Qi W, Kong K.

Spine (Phila Pa 1976). 2011 Nov 15;36(24):E1547-54. doi: 10.1097/BRS.0b013e318210f063.

PMID:
21270680
19.

[Accuracy of related parameters to screw placement in lower cervical pedicle measured by spinal virtual surgery system].

Cao J, He F, Li C, Liang Q, Li Z, Jiang Z.

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011 Mar;25(3):316-22. Chinese.

PMID:
21500585
20.

[Design and experimental study of individual drill templates for atlantoaxial pedicle screw fixation].

Qin W, Quan Z, Liu Y, Ou Y.

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2010 Oct;24(10):1168-73. Chinese.

PMID:
21046800
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk