Format
Items per page
Sort by

Send to:

Choose Destination

Links from PubMed

Items: 1 to 20 of 166

1.

Highly sensitive ochratoxin A impedimetric aptasensor based on the immobilization of azido-aptamer onto electrografted binary film via click chemistry.

Hayat A, Sassolas A, Marty JL, Radi AE.

Talanta. 2013 Jan 15;103:14-9. doi: 10.1016/j.talanta.2012.09.048. Epub 2012 Oct 4.

PMID:
23200352
2.

A label free aptasensor for Ochratoxin A detection in cocoa beans: An application to chocolate industries.

Mishra RK, Hayat A, Catanante G, Ocaña C, Marty JL.

Anal Chim Acta. 2015 Aug 19;889:106-12. doi: 10.1016/j.aca.2015.06.052. Epub 2015 Aug 10.

PMID:
26343432
3.

Label-free impedimetric aptasensor for ochratoxin-A detection using iridium oxide nanoparticles.

Rivas L, Mayorga-Martinez CC, Quesada-González D, Zamora-Gálvez A, de la Escosura-Muñiz A, Merkoçi A.

Anal Chem. 2015;87(10):5167-72. doi: 10.1021/acs.analchem.5b00890. Epub 2015 May 1.

PMID:
25901535
4.

Immobilization of enzymes on ethynyl-modified electrodes via click chemistry.

Hayat A, Sassolas A, Rhouati A, Marty JL.

Methods Mol Biol. 2013;1051:209-16. doi: 10.1007/978-1-62703-550-7_13.

PMID:
23934806
5.

Polyaniline Langmuir-Blodgett film based aptasensor for ochratoxin A detection.

Prabhakar N, Matharu Z, Malhotra BD.

Biosens Bioelectron. 2011 Jun 15;26(10):4006-11. doi: 10.1016/j.bios.2011.03.014. Epub 2011 Mar 24.

PMID:
21514815
6.

Ultrasensitive one-step rapid detection of ochratoxin A by the folding-based electrochemical aptasensor.

Wu J, Chu H, Mei Z, Deng Y, Xue F, Zheng L, Chen W.

Anal Chim Acta. 2012 Nov 13;753:27-31. doi: 10.1016/j.aca.2012.09.036. Epub 2012 Oct 1.

PMID:
23107133
7.

A reusable impedimetric aptasensor for detection of thrombin employing a graphite-epoxy composite electrode.

Ocaña C, Pacios M, del Valle M.

Sensors (Basel). 2012;12(3):3037-48. doi: 10.3390/s120303037. Epub 2012 Mar 6.

8.

An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer.

Bonel L, Vidal JC, Duato P, Castillo JR.

Biosens Bioelectron. 2011 Mar 15;26(7):3254-9. doi: 10.1016/j.bios.2010.12.036. Epub 2010 Dec 30.

PMID:
21256729
9.

Reusable impedimetric aptasensor.

Radi AE, Acero Sánchez JL, Baldrich E, O'Sullivan CK.

Anal Chem. 2005 Oct 1;77(19):6320-3.

PMID:
16194094
10.

A label-free aptasensor for the sensitive and specific detection of cocaine using supramolecular aptamer fragments/target complex by electrochemical impedance spectroscopy.

Zhang DW, Zhang FT, Cui YR, Deng QP, Krause S, Zhou YL, Zhang XX.

Talanta. 2012 Apr 15;92:65-71. doi: 10.1016/j.talanta.2012.01.049. Epub 2012 Feb 3.

PMID:
22385809
11.

Label-free impedimetric aptasensor for lysozyme detection based on carbon nanotube-modified screen-printed electrodes.

Rohrbach F, Karadeniz H, Erdem A, Famulok M, Mayer G.

Anal Biochem. 2012 Feb 15;421(2):454-9. doi: 10.1016/j.ab.2011.11.034. Epub 2011 Dec 2.

PMID:
22200651
12.

Label-free electrochemical cocaine aptasensor based on a target-inducing aptamer switching conformation.

Hua M, Tao M, Wang P, Zhang Y, Wu Z, Chang Y, Yang Y.

Anal Sci. 2010;26(12):1265-70.

13.

Electrochemical functionalization of carbon surfaces by aromatic azide or alkyne molecules: a versatile platform for click chemistry.

Evrard D, Lambert F, Policar C, Balland V, Limoges B.

Chemistry. 2008;14(30):9286-91. doi: 10.1002/chem.200801168.

PMID:
18780382
14.

Amplified impedimetric aptasensor based on gold nanoparticles covalently bound graphene sheet for the picomolar detection of ochratoxin A.

Jiang L, Qian J, Yang X, Yan Y, Liu Q, Wang K, Wang K.

Anal Chim Acta. 2014 Jan 2;806:128-35. doi: 10.1016/j.aca.2013.11.003. Epub 2013 Nov 14.

PMID:
24331048
15.

Label-free impedimetric immunosensor for sensitive detection of ochratoxin A.

Radi AE, Muñoz-Berbel X, Lates V, Marty JL.

Biosens Bioelectron. 2009 Mar 15;24(7):1888-92. doi: 10.1016/j.bios.2008.09.021. Epub 2008 Oct 4.

PMID:
19013783
16.

Rolling chain amplification based signal-enhanced electrochemical aptasensor for ultrasensitive detection of ochratoxin A.

Huang L, Wu J, Zheng L, Qian H, Xue F, Wu Y, Pan D, Adeloju SB, Chen W.

Anal Chem. 2013 Nov 19;85(22):10842-9. doi: 10.1021/ac402228n. Epub 2013 Nov 8.

PMID:
24206525
17.

Sensitive and antifouling impedimetric aptasensor for the determination of thrombin in undiluted serum sample.

Qi H, Shangguan L, Li C, Li X, Gao Q, Zhang C.

Biosens Bioelectron. 2013 Jan 15;39(1):324-8. doi: 10.1016/j.bios.2012.07.040. Epub 2012 Jul 27.

PMID:
22884002
18.

DNA aptamers selection and characterization for development of label-free impedimetric aptasensor for neurotoxin anatoxin-a.

Elshafey R, Siaj M, Zourob M.

Biosens Bioelectron. 2015 Jun 15;68:295-302. doi: 10.1016/j.bios.2015.01.002. Epub 2015 Jan 2.

PMID:
25594161
19.

Simply amplified electrochemical aptasensor of ochratoxin A based on exonuclease-catalyzed target recycling.

Tong P, Zhang L, Xu JJ, Chen HY.

Biosens Bioelectron. 2011 Nov 15;29(1):97-101. doi: 10.1016/j.bios.2011.07.075. Epub 2011 Aug 4.

PMID:
21855315
20.

A sensitive impedimetric thrombin aptasensor based on polyamidoamine dendrimer.

Zhang Z, Yang W, Wang J, Yang C, Yang F, Yang X.

Talanta. 2009 Jun 15;78(4-5):1240-5. doi: 10.1016/j.talanta.2009.01.034. Epub 2009 Jan 24.

PMID:
19362182
Format
Items per page
Sort by

Send to:

Choose Destination

Supplemental Content

Write to the Help Desk